CV-A50 / CV-A60

6.6. Pulse Width Control Mode

The leading edge of the trigger pulse initiates the exposure. The exposure time (accumulation time) is governed by duration of the trigger pulse.

The resulting video is output as “odd field” for EIA and “even field” for CCIR, and appear 9H (EIA9 or 10H (CCIR) after the leading edge of WEN (polarity is user selectable).

The exposure time range is 1.5H to 1000H (shortest and longest pulse duration).

To use this mode:

 

 

Set function:

Trigger mode to “Pulse Width Control”

TR=2

 

Accumulation to “Field”

FR=0

 

Scanning to “Non-interlaced”

SC=1

 

Polarity and other functions

 

Input:

Ext. trigger to pin 5 on 6 pin connector (or pin 11 on 12 pin connector).

 

Ext HD to pin 6 on 12 pin connector. (If used)

 

Fig. 19. Pulse width control CCIR.

Fig. 20. Pulse width control EIA.

Important notes on using this mode:-

Do not input external VD signal at Pin No. 7 of the 12-pin Hirose connector, as it may disturb the external trigger function.

-13 -

Image 14
Contents CV-A50 / CV-A60 Table of Contents CV-A50 / CV-A60Standard Composition Main FeaturesGeneral Camera Housing and Dimensions Pin Assignment Pin Multi-connector DC-IN/VIDEO OUT, EXT.HD/VDPin Multi-connector Trigger and RS232C Trigger input Input and Output CircuitsVideo output HD and VD inputFunctions and Operations Basic functionsInput-output of HD/VD Signals Continuous Operation Non triggeredCV-A50 / CV-A60 Vertical timing details for interlaced. Ccir Vertical timing details for interlaced. EIA External Trigger Modes Start/stop Mode. TR=5Edge Pre-select Mode Important notes on using this modePulse Width Control Mode Pulse width control CcirPage Long Time Exposure Mode Long time exposure. Field accumulationStart/Stop Mode Start/stop mode. Interlaced with frame accumulationOther Functions Configuring the Camera RS-232C controlCV-A50/60 RS-232C command list Timing and shutter related commandsCamera Control Tool for CV-A50/60 1 HD/VD input-output selection Internal Switch and Jumper SettingsSelecting termination of HD/VD input signals Specifications CV-A50C CV-A50E CV-A60C CV-A60ECV-A50 or CV-A60 emulating CV-M50 interfacing Spectral SensitivityAppendix WEN out on pin 6 on 6 pin connector CV-A50/60 without sync on video outputPrecautions Typical CCD CharacteristicsUsers Record Camera type CV-A50/60