JAI CV-M91 operation manual Pulse Width Control Mode, Vertical timing for pulse width control PAL

Page 15

CV-M91

6.2.3. Pulse Width Control Mode

The exposure will start at the first HD after the trigger leading edge, and it stops between the first and second HD after the trigger trailing edge. An EEN pulse indicate the accumulation time, and a WEN pulse indicates that the resulting video is read out.

Refer to “7. Configuring the Camera.”

To use this mode:

 

Set function:

Trigger mode to “Pulse width control”. SW 1-4 to ON

 

On PK8407: JP301 open, JP302 open, JP311 open.

 

Accumulation to “Field”. SW 301-4 on PK8407 to OFF

 

Scanning to “Non-interlaced”. SW 1-5 to ON

 

Shutter Speed to “1/10,000”. SW 1-1 through 1-3 to ON

 

Other functions

Input:

Ext. trigger to pin 5 on 6-pin connector.

 

Ext HD to pin 6 on 12 pin connector. (If used).

Important notes on using this mode.

The duration of the trigger can be >1H to <900H. (>64 sec. to <60msec.)

To avoid 1H jitter it is recommended to synchronize the trigger to HD. (See fig. 11.)

A new trigger can not be applied before WEN is high

Fig. 21. Vertical timing for pulse width control PAL

Fig. 22. Vertical timing for pulse width control NTSC

- 14 -

Image 15
Contents CV-M91 CV-M91 Table of ContentsMain Features GeneralStandard Composition Locations Locations and FunctionsPin Assignment Pin Multi-connector DC-IN/TriggerPin Multi-connector Trigger and RS232C Pin no Signal RemarksVideo outputs Pin Sub D-connector VideoInput and Output Circuits Pin noHD, VD, WEN, EEN and Pclk output Prism unitInput/Output of Signals Functions and OperationsInput/output of HD/VD Out/VBS out on pin#6 9 pin sub-D Internal sync out/WEN outInternal pixel clock out VBS out on pin#4 12 pinLong time integration Trigger ModesPAL horizontal timing Continuous Operation Non triggeredVertical timing PAL interlaced Vertical timing Ntsc interlaced Vertical timing for edge pre-select PAL Edge Pre-select ModeVertical timing for pulse width control PAL Pulse Width Control ModeStart stop interlaced field integration Start Stop ModeLong time interlaced field integration Long time integrationOther Functions 1. SW1 on rear panel Configuring the CameraSwitch settings Switch settings insideShort Jumper settings insideBoard positions Switch and jumper positionsRS-232C control CV-M91command listWindow from camera control tool Camera Control Tool for CV-M91External Appearance and Dimensions SpecificationsSpectral sensitivity CV-M91P Specification tableOpto mechanical specifications CV-M91 Opto-mechanical specificationsPrecautions Typical CCD CharacteristicsAppendix Users Mode Settings Users Modifications Users RecordCamera type CV-M91 Revision Revision a Serial No ……………