5. LAMP INSTALLATION INSTRUCTIONS

Installing or replacing the lamp

Only install the lamp with the device unplugged from the mains.

The lamp has to be replaced when it is damaged or deformed.

Before replacing the lamp be sure the unit has ample time to cool, to avoid injury to yourself never touch the lamp when it is hot.

During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal.

Do not install lamps with a higher wattage. They generate higher temperatures than which the device was designed for.

For the installation, you need one MSD250/2 GY9.5 lamp;

Procedure:

1.Remove the two thumbscrews labeled “A” and “B” on the rear housing of the head.

2.Gently pull the lamp/socket assembly to access the lamp.

3.Gently remove the old lamp by grasping it by the ceramic base.

4.Carefully insert the new lamp into the socket. Please remember there is only one way to insert the lamp. Once the lamp has be inserted into the socket, gently slide the socket assembly back into place and fasten the two thumb screws.

©Elation Professional®

11

Focus Spot 250R™

Image 11
Contents Focus Spot 250R Focus Spot 250R Elation Professional Contents General Information Focus Spot 250R Never open this fixture while in use Safety Instructions Focus Spot 250R Features General Guidelines Installing or replacing the lamp Lamp Installation InstructionsLamp Optimization Mounting points Mounting and InstallationMounting Secure the Focus Spot 250R DMX-512 control connection Understanding DMXDMX-512 connection with DMX terminator ControllerFixture DMX address Focus Spot 250R Fixture Menu Default settings shadedRese ALL Test Menu Setting/Changing the DMX AddressMain Menu Functions Address MenuPlay Main Menu Play MenuRese Main Menu Rese Reset MenuLamp Menu Focus Spot 250R Rpan Menu Time MenuTime Main Menu Fine Menu Rtlt MenuMIC Menu Degr MenuDisp Menu Display MenuSpec Main Menu Fixture SettingsSpec Menu Controller Settings Reload the original factory settings Edit Menu Focus Spot 250R Focus Spot 250R Focus Spot 250R DMX Channel Traits PAN Channel 9 Focus Error Codes Focus Spot 250R Cleaning and Maintenance Year Limited Warranty Focus Spot 250R Power supply user selectable Technical SpecificationsPhotometric Data Gobos Dimensional Drawings Focus Spot 250R Elation Professional Focus Spot 250R Elation Professional Elation Professional