Elation Professional 28, 05 FOCUS SPOT 250R, Rev 10 manual Controller Settings

Page 30

Focus Spot 250R™

3.Tap the UP button until “RDMX” is displayed, press ENTER.

4.The display will show “ON/OFF.”

5.Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function.

6.Press ENTER to confirm.

7.Press MODE/ESC to return to the main menu.

Controller Settings:

1.Set the DMX value of channel 1 to a value of 7.

2.Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7" you can adjust the starting address between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511.

3.Use channel 3 to set your desired DMX starting address. For example: If you want to set the starting address to 57, set channel 1 to a value of “7,” set channel 2 to a value of “7” and use channel 3 to set your address to 57 by selecting a channel value of 57. Example 2: If you want to set the starting address to 420, set channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164" (256+164=420).

4.Wait for approximately 20 seconds for the unit to complete the address reset function.

DLOF – This feature allow you to control the lamp via DMX.

1.Access the main menu.

2.Tap the UP button until “SPEC” is displayed, press ENTER.

3.Tap the UP button until “DLOF” is displayed, press ENTER.

4.The display will show “ON/OFF.”

5.Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function.

6.Press ENTER to confirm.

7.Press MODE/ESC to return to the main menu.

DLAY – This function allow the user to set a lamp “strike” delay time. 1. Access the main menu.

©Elation Professional®

30

Focus Spot 250R™

Image 30
Contents Focus Spot 250R Focus Spot 250R Elation Professional Contents General Information Focus Spot 250R Never open this fixture while in use Safety Instructions Focus Spot 250R Features General Guidelines Lamp Installation Instructions Installing or replacing the lampLamp Optimization Mounting and Installation MountingMounting points Secure the Focus Spot 250R Understanding DMX DMX-512 control connectionController DMX-512 connection with DMX terminatorFixture DMX address Focus Spot 250R Default settings shaded Fixture MenuRese ALL Address Menu Setting/Changing the DMX AddressMain Menu Functions Test MenuPlay Menu Play Main MenuRese Reset Menu Lamp MenuRese Main Menu Focus Spot 250R Time Menu Time Main MenuRpan Menu Rtlt Menu Fine MenuDegr Menu MIC MenuDisplay Menu Disp MenuFixture Settings Spec MenuSpec Main Menu Controller Settings Reload the original factory settings Edit Menu Focus Spot 250R Focus Spot 250R Focus Spot 250R DMX Channel Traits PAN Channel 9 Focus Error Codes Focus Spot 250R Cleaning and Maintenance Year Limited Warranty Focus Spot 250R Technical Specifications Power supply user selectablePhotometric Data Gobos Dimensional Drawings Focus Spot 250R Elation Professional Focus Spot 250R Elation Professional Elation Professional