SAFETY INSPECTION/ MAINTENANCE
| PROCEDURE 2 | SAFETY INSPECTION/MAINTENANCE | 
TROUBLESHOOTING GUIDE
| SYMPTOM | PROBABLE CAUSE | SOLUTION | |
| 
 | 
 | 
 | |
| LIMITED DRIVING | Batteries not charged long enough. | Charge batteries overnight or | |
| DISTANCE. | 
 | ensure 8 hours of charge between | |
| 
 | 
 | use times (PROCEDURE 4). | |
| 
 | Batteries weak, won't hold charge. | Replace Batteries | |
| 
 | 
 | (PROCEDURE 4). | |
| 
 | 
 | 
 | |
| BATTERIES NOT | Charger not working. | Replace Charger. | |
| CHARGING. | Battery Connections loose. | Check all connections. Secure | |
| 
 | |||
| 
 | 
 | connections (PROCEDURE 4). | |
| 
 | NO current at wall outlet. | Switch to another wall outlet. | |
| 
 | BAD connection on Charger, | Replace Charger or internal | |
| 
 | Charger Cable, Plug or Internal | repairs required. Contact Dealer | |
| 
 | Wiring problem. | or Invacare. | |
| 
 | 
 | 
 | |
| BATTERIES DRAW | Battery Failure. | Replace Batteries | |
| EXCESSIVE CURRENT | 
 | (PROCEDURE 4). | |
| WHEN CHARGING. | 
 | 
 | |
| 
 | 
 | 
 | |
| CHARGE INDICATOR | Batteries weak, won't hold charge. | Replace Batteries | |
| SHOWS LOW CHARGE | 
 | (PROCEDURE 4). | |
| LEVEL IMMEDIATELY | Charger not operating. | Replace Charger. | |
| AFTER CHARGING. | |||
| 
 | 
 | ||
| 
 | 
 | 
 | |
| BATTERY INDICATOR | Have charger checked. | Service or replace charger. | |
| FLASHES THE CHARGE | 
 | Contact Dealer or Invacare. | |
| LEVEL IS LOW - TOO | Weak batteries. | Replace batteries (PROCEDURE | |
| SOON AFTER BEING | 
 | 4). | |
| RECHARGED. | 
 | 
 | |
| 
 | 
 | 
 | |
| SCOOTER WILL NOT | Engage  | ||
| DRIVE. | 
 | (procedure 3) | |
| 
 | Batteries require charging. | Charge batteries (PROCEDURE 4). | |
| 
 | Key not fully plugged in. | Ensure key is inserted fully into | |
| 
 | 
 | power plug jack. | |
| 
 | Charger plugged in. | Unplug charger from scooter. | |
| 
 | Circuit breaker tripped. | Reset breaker. If breaker trips | |
| 
 | 
 | again, it may indicate need for | |
| 
 | 
 | internal repairs. Contact Dealer | |
| 
 | 
 | or Invacare. | |
| 
 | Soft stop is engaged.If key is turned | With key in the "OFF" position, | |
| 
 | "OFF" while driving, the scooter | wait 30 seconds and turn key to | |
| 
 | artificially holds power for 1.5 seconds | "ON" position. | |
| 
 | slowly decelerating unit to a stop. | 
 | |
| 
 | 
 | 
 | |
| MOTOR “CHATTERS” | Fuse is Blown. | Replace Fuse (PROCEDURE 3). | |
| OR RUNS | Electrical malfunction. | Contact Dealer or Invacare. | |
| IRREGULARLY. | 
 | 
 | |
| 
 | 
 | 
 | 
| Invacare Scooters | 18 | Part No. 1090132 Rev F | 