Philips KX-HCM8 Default Settings List, Items Factory Default Indispensable setting Value Network

Page 98

98

 

 

 

 

 

 

 

 

No

 

 

Items

Factory Default

Indispensable setting

 

Note

 

 

 

value

 

 

 

 

 

 

 

 

 

 

1

Network

1.

Network Configuration

Checked

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

2.

Port No.

80

-

 

1–65535

 

 

 

 

 

 

 

 

 

 

 

 

 

Static : IP Address

192.168.0.253

If necessary

 

(*1)

 

 

 

 

 

 

 

 

 

 

 

 

 

Static : Subnet Mask

255.255.255.0

If necessary

 

(*1)

 

 

 

 

 

 

 

 

 

 

 

 

DHCP : Host Name

[Blank]

If necessary

(*3) 0 to 63 Characters

 

 

 

 

 

 

 

 

 

 

 

 

3.

Default Gateway

[Blank]

Required when using Gateway

 

(*1)

 

 

 

 

 

 

 

 

 

 

 

 

4.

DNS Server1 & DNS server 2

[Blank]

Required when using DNS

 

(*1)

 

 

 

5.

DDNS

No check

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

Your e-mail address

[Blank]

Required when using DDNS

(*4) 5 to 255 Characters

 

 

 

 

 

 

 

 

 

 

 

6.

Max Bandwidth usage (Mbps)

Unlimited

-

0.1, 0.2, 0.3, 0.5, 1.0,Unlimited

 

 

 

 

 

 

 

 

 

2

Name/Time

1.

Camera Name

NetworkCamera

-

(*3) and (*7) 1 to 15 Characters

 

 

 

 

 

 

 

 

 

 

 

 

2.

Date and Time

AM/PM

-

 

-

 

 

 

 

(AM/PM, 24H)

 

 

 

 

 

 

 

 

 

 

 

 

2.

Date and Time

No changing

-

 

-

 

 

 

 

(Year/Month/Day/Hour/Minute)

 

 

 

 

 

 

 

 

 

 

 

 

3.

Auto Adjustment

No check

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

NTP Server Address or Host Name

[Blank]

-

(*1) or (*3) 1 to 255 Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

Time Zone

GMT-05:00

-

 

-

 

 

 

 

 

 

 

 

 

 

3

Security:

1.

Authentication Enable

None

-

 

-

 

 

Administrator

 

 

 

 

 

 

 

 

2.

ID

[Blank]

Required when setting Authentication

(*3)

4 to 15 Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Password

[Blank]

Required when setting Authentication

(*3)

4 to 15 Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

Retype Password

[Blank]

Required when setting Authentication

(*3)

4 to 15 Characters

 

 

 

 

 

 

 

 

 

4

Security:

(1.) User ID List

No entry

-

 

-

 

 

General User

 

 

 

 

 

 

 

 

(2.) New User: ID

[Blank]

Required when setting General User

(*3)

4 to 15 Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

New User: Password

[Blank]

Required when setting General User

(*3)

4 to 15 Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

New User: Retype Password

[Blank]

Required when setting General User

(*3)

4 to 15 Characters

 

 

 

 

 

 

 

 

 

5

Top View Image

1.

Language

English (US)

-

French, German, Italian,

 

 

Setting

Spanish, Japanese, etc.

 

 

 

 

 

 

 

 

 

2.

Top Page title

[Blank]

-

(*6) and (*7) 0 to 63 Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

Image URL

[Blank]

-

(*8)

0 to 127 Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

Link URL

[Blank]

-

(*8)

0 to 127 Characters

 

 

 

 

 

 

 

 

 

5.2 Default Settings List

Operating Instructions

Image 98
Contents Network Camera Introduction For operation assistance CallTrademarks Network Camera MemoImportant Safety Instructions Table of Contents Index 115 Specification and TroubleshootingTechnical Guides Section Main Features Getting to Know Network CameraMulti-Language Display Update FirmwareAuthentication System Requirements Authentication-System Security Feature Authentication windowIncluded Accessories Setup CD-ROM Camera Feature Locations Front ViewRear View Bottom ViewNetwork Camera Setup Installation Procedure Network Camera Configuration Type Type 2-Internet Connection with a Broadband RouterType 3-Internet Direct Connection with a Modem Type 4-Direct Connection with a PCHow to turn on Network Camera for Installation Network parameters memo for Network Camera Network ParametersPreparing the Network Parameters for Network Camera Network Parameters Table Network Camera Configuration Type Port NoDefault IP addressHow to refer the network parameters from the PC Enter winipcfg and click OK. IP configuration window appearsSetting IP Address of the PC in Type 4 Configuration Type Private IP address Proxy Server Setting Operating Instructions Simple Installation using the Setup CD-ROM Operating Instructions Operating Instructions Click the language to change the display Network Camera Access from the Internet Port Forwarding IP Masquerade featureTop If Top Page does not appearOperating Instructions Network Camera Screen and Setup Window Network Camera Flow Chart Http//Global IP address of Broadband RouterPortNo Top TopExample Multi-Camera Motion JpegSingle Camera HelpActiveX Controls Single Camera Screen Using Operation Bar Non Transfer mode Alarm/Timer mode Viewing Buffered Image ScreenPrimary ViewerClicking Start Capture SecondaryMulti-Camera Screen Setup Setup Go to Top AdministratorCamera Setup Name/TimeFunctions of Network Camera Entered. If any operational issues are changed, tryThis option first. Refer to Go to Top Network Instructions for the data fields Enter only the numberDhcp Ddns File size of the imageName Name/TimeCamera DateAuto AdjustmentTime Changed AM/PM or 24H Time ZoneSecurity Administrator Click Security Administrator on SetupRetype EnableFor Setup Password Click Security General User on Setup Security General UserNew User User ID ListDelete or Modify Top View Image Image ResolutionInstructions for the data fields Top 160 x Image QualityImage Transfer Non Transfer mode Transfer in the Alarm Mode Click Alarm on Image Transfer windowActive Time of Trigger Alarm enable conditionSets the image resolution and image quality Login timing Over write setting Data transfer methodSetting Example Setting explanation Transfer in the Timer Mode Buffers or transfers by the timer trigger Login timing Over write setting Camera Setup Fixed Indoor Power LineWhite Balance FixedMulti-Camera URL * 1 or Host Enable check boxIP Address or Camera NameClick External Output Control on Setup External Output ControlIndicator Control Status Restart Click Restart NowUpdate Firmware Click Update Firmware Operating Instructions Reset to Factory Default Click Reset to Factory Default on Setup Click ExecuteTechnical Guides Tripod Mounting MountingFlexible Stand Mounting Wall Mounting Ceiling Mounting Power Indicator On the Stand On the wall On the ceiling Top Pin Function Interfacing to the External I/OExplanation of External I/O External Sensor InputCircuit Diagram Example Ascii and ISO-8859-1 Character Table Unavailable character setDisplayable character set Maintenance Specification and Troubleshooting Network Camera Reset Procedure-Default Settings Default Settings List Items Factory Default Indispensable setting Value NetworkImage Transfer 100 For assistance, please call 101 Items Factory Default Indispensable setting Value Camera Other Specification Description SpecificationsNetwork Camera Specifications Description SMTP, FTP Problem Cause and Remedy TroubleshootingAbout Network Camera Setup For Indicator Control window ISP Network window onAbout Network Camera Setup Problem Cause and Remedy About Top View Image screen View Image Setting window on About Other TroublesConfirmation of Network Camera Operation Click the language to change the display FCC and Other Information 114 Index Operating Instructions TCP/IP For product service When you ship the product