[2] | [4] | [5] |
Connecting Lamp Heads
One or two lamp heads can be connected to the lamps head sockets [2]. When connecting the lamp head plug, align the dots on the plug with the white dot on the generator panel. Secure by turn- ing the locking ring on the plug clockwise.
Energy Control
The energy output is regulated with the control ENERGY [5]. The energy can be adjusted in 1/6 f:stop increments, from 1/1 down to 1/32 of the total energy (equivalent to six f:stops). At any change of the energy output the white ready lamp [9] will start flashing indicating that the energy needs to be dumped i. e. by pushing the test button [9]. The generator will thereafter be charged to the chosen energy output.
Choice of Modelling Light
The control marked MOD.LIGHT [12] is used to choose the following alternatives:
OFF | Modelling light is turned off |
1/1 | Modelling light is receiving the designated proportional energy at full intensity deter- |
| mined by the position of the ENERGY control [5] |
1/2 | Modelling light* is receiving the designated proportional energy at half the intensity |
| determined by the position of the ENERGY control [5]. |
MAX | Modelling light is at maximum light output regardless of energy setting |
When connecting two lamp heads or a ProTwin the modelling light proportionality is automatically adjusted.
*The alternative 1/2 proportional modelling light is chosen in those cases when a
28