Fairchild CAM/CMOS-2K.LS Power Supply, Camera Pin # Frame Grabber Pin # Channel Link Signal

Page 12

Table 2.2.1

Camera Pin #

Frame Grabber Pin #

Channel Link Signal

1

1

Inner shield

14

14

Inner shield

2

25

X0

15

12

X0+

3

24.0

X1-

16

11

X1+

4

23

X2-

17

10

X2+

5

22

Xclk

18

9

Xclk+

6

21

X3

19

8

X3+

7

20

SerTC+

20

7

SerTC-

8

19

SerTFG-

21

6

SerTFG+

9

18

CC1-

22

5

CC1+

10

17

CC2-

23

4

CC2+

11

16

CC3-

24

3

CC3+

12

15

CC4-

25

2

CC4+

13

13

Inner shield

26

26

Inner shield

Notes:

Exterior overshield is connected to the shells of the connectors on both ends.

3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.

Unused pairs should be terminated in 100 ohms at both ends of the cable.

2.3 Power Supply

The camera uses a single voltage input, normally set to 5.0V.

Ripple and noise is required to be < 20 mV RMS.

Power is supplied through a Hirose connector.

When installing the mating connector, be sure to line up the slots. This action will assure that you will not bend any of the pins.

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 12 of 42

Image 12
Contents OWL Camera Series CAM/CMOS-2K.LS EMC Conformance EMCCAM/CMOS-2K.LS Line Scan Camera Rev B Fairchild Imaging, Inc TerminologyTable of Contents Troubleshooting Handling InstructionsProduct Support Camera Link IntroductionCamera Highlights DescriptionProgrammability UsabilityCamera Specification RDI and Mrdi Performance Specification Full Spectrum of ApplicationsThermal Considerations LinkRDI and Mrdi Responsivity Curve Image Sensor Page Installation Overview Connectors, Pinouts, and CablesCamera Hardware Interface Power Supply Camera Pin # Frame Grabber Pin # Channel Link SignalLED Indicator Status Lamp Hirose ReceptacleBack View of CAM/CMOS 2K.LS Commands Camera ControlQuick Start with the Camera LinkTM Interface You must cover lens when performing this operation SSM LED Camera Command Summary Command Definition SummaryFour Modes for Synchronizing with the CAM/CMOS 2K.LS GSNSummary of CAM/CMOS-2K.LS Modes Line Start End 1 -- Mode 1 Freerunning 2 -- Mode 2 ExSync Synchronization ExSync Camera Input LineValid Camera Output ElectShutter Synchronization Timing Values CAM/CMOS-2K.LSCamera Dimensions and Mounting Facilities Mechanical and Optical GuidanceLensing Lens Mount Extender TubePage Page Lenses Positioning Accuracy of the Sensor Chip in the CameraIllumination Light SourcesLens Modeling Cleaning the Sensor Window Handling InstructionsElectrostatic Discharge Preventing ESD DamageTroubleshooting Check the Obvious Things Out FirstUse the Camera Control Interface to Perform Checks Other Areas You Should CheckData Clocking/Output Signals No Output Or Non Specification OutputEverything Seems To Be Working, But No Image Horizontal Lines or Patterns in OutputProduct Support Channel Link is a Widely-Used Signaling Method Camera LinkTM IntroductionVideo Data Signals Camera Control SignalsCommunication Power Port AssignmentsFor More Information on CameraLinkTM Camera Link Connections -- the MDR 26-Pin Connector Figure A.1 Channel Link OperationPage Page Figure A.4 Camera Link Cable