Fairchild CAM/CMOS-2K.LS Everything Seems To Be Working, But No Image, Images Look Noisy

Page 34

Everything Seems To Be Working, But No Image

Remove the cover from your PC and reset all the cards into the Mother board. Sometimes when you move your PC, cards inside the PC work themselves loose.

Data Clocking/Output Signals

Verify the presence of all data clocking and output signals.

Horizontal Lines or Patterns in Output

To eliminate this type of problem use a DC light source.

No Output Or Non Specification Output

If your camera has no output or is putting out an unspecified signal unkown to you. Check the length of your cable. If it is unnecessarily too long, and is also not shielded, your cable most likely is picking up radiated noise and is inputting the noise into your camera.

Vertical Patterns in Output

Sometimes you might see patterns in your output. Most likely these are caused by dirt on your lens or possibly contaminants on the sensor window. Clean both to remove all contaminants.

Images are too Bright or too Dark

The causes to this problem should be obvious, but many times are overlooked. If your image that you have captured is too dark or light, then experiment with the lens aperture. Sometimes if you lengthen or shorten the exposure time this will effect your image.

Remember your camera control command “CPG”. This command allows you to either increase or decrease pixel gain, which can have a dramatic impact on your image.

Lastly, don’t forget to check your lighting.

Images Look Noisy

There are several things that can cause this condition. Remember our camera command “CPG”. Work with this command. Try increasing and decreasing pixel gain until you find the right setting.

Look for an increase in dark current. If the ambient temp. increases this will cause noise in the image.

Look at your light source. If your light source is AC instead of DC this will make the image look noisy. Also if the object you are inspecting has different surface textures this could produce an image that may look noisy.

Bits That Do Not Change Value

If you see that data bits are not changing values, after you have changed them, then the first thing to check is that the camera is not saturated by preventing light from entering. Next, disconnect the Camera Link cable from the camera. Check the digital signals at the output of the camera, ensuring that the correct values and signals are present.

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 34 of 42

Image 34
Contents OWL Camera Series CAM/CMOS-2K.LS EMC Conformance EMCCAM/CMOS-2K.LS Line Scan Camera Rev B Fairchild Imaging, Inc TerminologyTable of Contents Product Support TroubleshootingHandling Instructions Camera Link IntroductionProgrammability Camera HighlightsDescription UsabilityCamera Specification RDI and Mrdi Performance Specification Full Spectrum of ApplicationsThermal Considerations LinkRDI and Mrdi Responsivity Curve Image Sensor Page Connectors, Pinouts, and Cables Installation OverviewCamera Hardware Interface Power Supply Camera Pin # Frame Grabber Pin # Channel Link SignalHirose Receptacle LED Indicator Status LampBack View of CAM/CMOS 2K.LS Camera Control CommandsQuick Start with the Camera LinkTM Interface You must cover lens when performing this operation SSM LED Camera Command Summary Command Definition SummaryFour Modes for Synchronizing with the CAM/CMOS 2K.LS GSNSummary of CAM/CMOS-2K.LS Modes Line Start End 1 -- Mode 1 Freerunning 2 -- Mode 2 ExSync Synchronization ExSync Camera Input LineValid Camera Output ElectShutter Synchronization Timing Values CAM/CMOS-2K.LSCamera Dimensions and Mounting Facilities Mechanical and Optical GuidanceLensing Lens Mount Extender TubePage Page Illumination LensesPositioning Accuracy of the Sensor Chip in the Camera Light SourcesLens Modeling Electrostatic Discharge Cleaning the Sensor WindowHandling Instructions Preventing ESD DamageUse the Camera Control Interface to Perform Checks TroubleshootingCheck the Obvious Things Out First Other Areas You Should CheckEverything Seems To Be Working, But No Image Data Clocking/Output SignalsNo Output Or Non Specification Output Horizontal Lines or Patterns in OutputProduct Support Channel Link is a Widely-Used Signaling Method Camera LinkTM IntroductionCamera Control Signals Video Data SignalsCommunication Port Assignments PowerFor More Information on CameraLinkTM Camera Link Connections -- the MDR 26-Pin Connector Figure A.1 Channel Link OperationPage Page Figure A.4 Camera Link Cable