Table 2.3.1

 

Hirose Receptacle

 

 

 

Pin #

 

Description

 

 

 

1

 

+5.0 - +6.0 V DC

 

 

 

2

 

+5.0 – +6.0V DC

 

 

 

3

 

Ground

 

 

 

4

 

Ground

 

 

 

If you are using an adjustable lab power supply it is extremely important that you apply the apppropriate voltage to your camera. Incorrect voltage might damage the camera.

Figure 2.3.1

Back View of CAM/CMOS – 2K.LS

2.4 LED Indicator Status Lamp

Table 2.4.1

Light Color

Status

 

 

Green

Running

 

 

Blinking Amber/Red

Busy with command

 

 

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 13 of 42

Image 13
Contents OWL Camera Series CAM/CMOS-2K.LS EMC EMC ConformanceTerminology CAM/CMOS-2K.LS Line Scan Camera Rev B Fairchild Imaging, IncTable of Contents Handling Instructions TroubleshootingProduct Support Camera Link IntroductionDescription Camera HighlightsProgrammability UsabilityFull Spectrum of Applications Camera Specification RDI and Mrdi Performance SpecificationLink Thermal ConsiderationsRDI and Mrdi Responsivity Curve Image Sensor Page Connectors, Pinouts, and Cables Installation OverviewCamera Hardware Interface Camera Pin # Frame Grabber Pin # Channel Link Signal Power SupplyHirose Receptacle LED Indicator Status LampBack View of CAM/CMOS 2K.LS Camera Control CommandsQuick Start with the Camera LinkTM Interface You must cover lens when performing this operation SSM LED Command Definition Summary Camera Command SummaryGSN Four Modes for Synchronizing with the CAM/CMOS 2K.LSSummary of CAM/CMOS-2K.LS Modes Line Start End 1 -- Mode 1 Freerunning 2 -- Mode 2 ExSync Synchronization ExSync Camera Input LineValid Camera Output ElectShutter CAM/CMOS-2K.LS Synchronization Timing ValuesMechanical and Optical Guidance Camera Dimensions and Mounting FacilitiesLens Mount Extender Tube LensingPage Page Positioning Accuracy of the Sensor Chip in the Camera LensesIllumination Light SourcesLens Modeling Handling Instructions Cleaning the Sensor WindowElectrostatic Discharge Preventing ESD DamageCheck the Obvious Things Out First TroubleshootingUse the Camera Control Interface to Perform Checks Other Areas You Should CheckNo Output Or Non Specification Output Data Clocking/Output SignalsEverything Seems To Be Working, But No Image Horizontal Lines or Patterns in OutputProduct Support Camera LinkTM Introduction Channel Link is a Widely-Used Signaling MethodCamera Control Signals Video Data SignalsCommunication Port Assignments PowerFor More Information on CameraLinkTM Figure A.1 Channel Link Operation Camera Link Connections -- the MDR 26-Pin ConnectorPage Page Figure A.4 Camera Link Cable