Fairchild CAM/CMOS-2K.LS user manual Ssm

Page 16

SSM

This command allows you to set the Sync mode. When selecting the option you need, enter the appropriate single digit number, and then hit enter.

Value Function

The camera returns …………..…..1 Free run

2External Sync

3External Sync, fixed integration

4External Sync, electronic shutter

SCM

This command allows you to select a correction mode. When selecting the option you need, enter the appropriate single digit number and then hit enter.

Value Function

The camera returns……………….1 M1 (1st memory)

2M2 (2nd memory)

3Offset Correction

4Gain Correction

5No Correction

6Full Correction

STP

This command allows you to select a test pattern. When selecting the option you need, enter the appropriate single digit number, and then hit enter.

Value Function

No output from camera…………1 Horizontal Ramp

2Vertical Ramp

3Vertical Bars

4Vertical Ramp and Bars

50

64095

Other Video

CBR

This command allows you to change the Baud Rate. You will not see anything on your monitor.

Here is a table of stored rates in the camera…Value

Function

1

9600

2

19200

3

38400 (Default)

4

57600

5

115200

If you can’t resist changing the baud rate, select the appropriate single digit number and hit enter.

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 16 of 42

Image 16
Contents OWL Camera Series CAM/CMOS-2K.LS EMC Conformance EMCCAM/CMOS-2K.LS Line Scan Camera Rev B Fairchild Imaging, Inc TerminologyTable of Contents Troubleshooting Handling InstructionsProduct Support Camera Link IntroductionCamera Highlights DescriptionProgrammability UsabilityCamera Specification RDI and Mrdi Performance Specification Full Spectrum of ApplicationsThermal Considerations LinkRDI and Mrdi Responsivity Curve Image Sensor Page Connectors, Pinouts, and Cables Installation OverviewCamera Hardware Interface Power Supply Camera Pin # Frame Grabber Pin # Channel Link SignalHirose Receptacle LED Indicator Status LampBack View of CAM/CMOS 2K.LS Camera Control CommandsQuick Start with the Camera LinkTM Interface You must cover lens when performing this operation SSM LED Camera Command Summary Command Definition SummaryFour Modes for Synchronizing with the CAM/CMOS 2K.LS GSNSummary of CAM/CMOS-2K.LS Modes Line Start End 1 -- Mode 1 Freerunning 2 -- Mode 2 ExSync Synchronization ExSync Camera Input LineValid Camera Output ElectShutter Synchronization Timing Values CAM/CMOS-2K.LSCamera Dimensions and Mounting Facilities Mechanical and Optical GuidanceLensing Lens Mount Extender TubePage Page Lenses Positioning Accuracy of the Sensor Chip in the CameraIllumination Light SourcesLens Modeling Cleaning the Sensor Window Handling InstructionsElectrostatic Discharge Preventing ESD DamageTroubleshooting Check the Obvious Things Out FirstUse the Camera Control Interface to Perform Checks Other Areas You Should CheckData Clocking/Output Signals No Output Or Non Specification OutputEverything Seems To Be Working, But No Image Horizontal Lines or Patterns in OutputProduct Support Channel Link is a Widely-Used Signaling Method Camera LinkTM IntroductionCamera Control Signals Video Data SignalsCommunication Port Assignments PowerFor More Information on CameraLinkTM Camera Link Connections -- the MDR 26-Pin Connector Figure A.1 Channel Link OperationPage Page Figure A.4 Camera Link Cable