Fairchild CAM/CMOS-2K.LS user manual Mode 2 ExSync Synchronization

Page 22

Figure 3.4.2 -- Mode 2: ExSync Synchronization

...gives the user asynchronous hardware control over initiation of the camera readout cycle

and over termination of the line period...

...separately gives the user asynchronous hardware control

 

 

 

 

 

 

 

 

 

 

 

tLinePeriod

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n

 

 

 

 

 

n+1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

>tMinSync

 

 

 

 

 

 

tReset2

 

 

 

 

 

tIntegration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tHold

ExSync

Camera Input

LineValid

Camera Output

 

tReadout

 

2048 Clock Cycles

tXFR

Data Camera Output

1

2

3

1023

1024

Strobe Camera Output

Line Valid Camera Output

Notes specific to this mode

1Unlike Freerunning mode, the user triggers (separately) both the CAM/CMOS - 2K.LS readout cycle, and the CAM/CMOS - 2K.LS reset-&-integration cycle. All of the modes other than Freerunning mode allow the user to do this

2The user initiates a readout cycle by taking ExSync low as shown above. Readout actually begins a time

"tXFR" after ExSync is taken low, and lasts 2048 clock cycles

3The user can read data from the CAM/CMOS - 2K.LS while LineValid is high as shown above and explained in Figure 3.4.1

4The reset-&-integration cycle to be read out in the next period "n+1" is initiated by ExSync returning high;

integration begins when reset is complete a time "tReset" after ExSync goes high, and continues

for the remainder of "tLinePeriod". The user can therefore shorten integration time by increasing "tHold" above

5The line period is set by the user by returning ExSync low, thereby initiating the next "n+1th" readout cycle

6The minimum time that ExSync can be held low is "tMinSync" as shown above

7Integration is cut off when the user takes ExSync low again as shown in the waveforms above

8The line period must be greater than or equal to "tReadout" plus tXfr", which sets maximum line rate to 50K lines/sec

9If the user brings the ExSync Camera Input low prior to "tXFR" + "tReadout" after ExSync goes low, then the CAM/CMOS 2K.LS delays initiation of the "n+1th" readout cycle until "tReadout"+ "tXFR" has elapsed after ExSync last went low

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 22 of 42

Image 22
Contents OWL Camera Series CAM/CMOS-2K.LS EMC Conformance EMCCAM/CMOS-2K.LS Line Scan Camera Rev B Fairchild Imaging, Inc TerminologyTable of Contents Product Support TroubleshootingHandling Instructions Camera Link IntroductionProgrammability Camera HighlightsDescription UsabilityCamera Specification RDI and Mrdi Performance Specification Full Spectrum of ApplicationsThermal Considerations LinkRDI and Mrdi Responsivity Curve Image Sensor Page Connectors, Pinouts, and Cables Installation OverviewCamera Hardware Interface Power Supply Camera Pin # Frame Grabber Pin # Channel Link SignalHirose Receptacle LED Indicator Status LampBack View of CAM/CMOS 2K.LS Camera Control CommandsQuick Start with the Camera LinkTM Interface You must cover lens when performing this operation SSM LED Camera Command Summary Command Definition SummaryFour Modes for Synchronizing with the CAM/CMOS 2K.LS GSNSummary of CAM/CMOS-2K.LS Modes Line Start End 1 -- Mode 1 Freerunning 2 -- Mode 2 ExSync Synchronization ExSync Camera Input LineValid Camera Output ElectShutter Synchronization Timing Values CAM/CMOS-2K.LSCamera Dimensions and Mounting Facilities Mechanical and Optical GuidanceLensing Lens Mount Extender TubePage Page Illumination LensesPositioning Accuracy of the Sensor Chip in the Camera Light SourcesLens Modeling Electrostatic Discharge Cleaning the Sensor WindowHandling Instructions Preventing ESD DamageUse the Camera Control Interface to Perform Checks TroubleshootingCheck the Obvious Things Out First Other Areas You Should CheckEverything Seems To Be Working, But No Image Data Clocking/Output SignalsNo Output Or Non Specification Output Horizontal Lines or Patterns in OutputProduct Support Channel Link is a Widely-Used Signaling Method Camera LinkTM IntroductionCamera Control Signals Video Data SignalsCommunication Port Assignments PowerFor More Information on CameraLinkTM Camera Link Connections -- the MDR 26-Pin Connector Figure A.1 Channel Link OperationPage Page Figure A.4 Camera Link Cable