Cannon 300II manual Maintenance Troubleshooting, Replacing the lamp

Page 44

MAINTENANCE AND TROUBLESHOOTING

MAINTENANCE AND

TROUBLESHOOTING

This part of the manual describes how to replace the halogen lamp, cleaning the scanner and dealing with errors. Regular scanner maintenance is essential to eusure optimum performance and a long service life from your scanner.

Replacing the lamp

The lamp projects the film image onto the screen, and the proce- dure for replacing the lamp is described below, along with some precautions to be observed when handling the lamp unit. If the lamp burns out, use the procedure below to replace it.

When the lamp burns out, “LP” appears on the Print/Error dis- play.

1.

2.

HEAT CAUTION

Immediately after the lamp burns out, the lamp and the metal components of the lamp unit are very hot. To avoid being burned, allow the lamp ample time to cool down before touching it. The lamp will cool down more quickly if you leave the scanner switched on for some minutes with “LP” displayed. After checking that the lamp and the metal components have cooled down, proceed with lamp replacement.

When the lamp burns out, leave the scanner switched on for several minutes until the lamp has cooled down.

After waiting at least 5 minutes, check that the lamp has cooled down and then switch the scanner off.

Firmly grip the lamp unit on the right side of the main unit and slowly pull the lamp unit out.

When you remove the lamp unit, “L5” appears in the Print/Error display.

CAUTION

To avoid injury, do not touch the interior of the main unit after you have removed the lamp unit.

3.Push the lever on the side of the lamp and remove the burned out lamp.

HEAT CAUTION

Immediately after the lamp burns out, the lamp and the metal components of the lamp unit are very hot. Never handle the lamp or lamp unit while they are still hot.

42

MS 300_english.p65

42

07.5.14, 10:14

Image 44
Contents English FCC Regulations For 120V models Radio Interference Regulations For 120V modelsRèglement SUR LE Brouillage Radioélectrique For 120V models CopyrightIntroduction Conventions Heat CautionContents Specifications Index Work Safety Choosing a safe location Before YOU BeginMS 300english.p65 Power supply Daily handling Heat Cautions Features of the Microfilm Scanner Scanner mode DMP modeReader-printer mode About operation modesUnpacking Whats in the box? Options Important parts and their functions Operation panelOperation panel Negative/Positive keyPreparing the carrier Fiche Carrier 190RIIAutocarrier 100C AC100C FS ControllerSwitching the lens Preparing the lensFixed lens Zoom lensesSlide the other lens into the unit Preparing optional printer for the DMP mode When using a Scsi card When using a USB connectionHardware requirements Operating system requirementsScsi cable Connecting via ScsiScsi card Connecting via USB Connecting to a ComputerUSB port USB cableTurning the power off Turning the Power ON/OFFTurning the power on Scanner recognition Case of Windows 98/MeCase of Windows 2000/XP Canon MS300 Scsi Scanner Device Turning the Power ON/OFF Installing the ISIS/TWAIN driver About the SoftwareInstalling CapturePerfect Using the software Using the ISIS/TWAIN Driver Using CapturePerfectStarting CapturePerfect Closing CapturePerfectAbout the Reader-Printer mode Starting up Reader-Printer modeSetting the Reader-Printer mode Starting up the Reader-Printer modeExiting the Reader-Printer mode Uninstalling the software Setting the Scanner Brightness adjustment Automatic adjustmentManual adjustment Selecting the polarityDefining an area for trimming Trimming/border removal settingsTrimming Using the area setting cursors optional Border removalRemoving the entire border Leaving a margin around the imagePrinting DMP mode Using the FileprintPrinting DMP mode User mode setting functions Power saver mode User ModeUser mode setting Scanning resolution Cleaning modeSwitching the operation modes Hi-speed scanningMaintenance Troubleshooting Replacing the lampMaintenance and Troubleshooting Cleaning the lens Routine cleaningCleaning the screen and main unit Cleaning the Fixing Rollers Cleaning paperTroubleshooting Problem SolutionDMP mode User call errorsScanner mode When you cannot clear a service call error Service Call ErrorsIf the E000 fixer error is displayed Specifications Power ON/OFF Index08.6.5, 257 PM Canon Electronics INC