Toshiba IK-TF5U instruction manual Manu/Off, Changing gamma correction, Changing master pedestal

Page 22

( 4 ) PROCESS

Gamma Correction (GAMMA)

Select either OFF or ON of Gamma Correction.

Master Pedestal (M. PED)

Adjust the Pedestal level of each RGB.

R Pedestal (R. PED)

Adjust the Pedestal level of Red.

B Pedestal (B. PED)

Adjust the Pedestal level of Blue.

Shading Correction (SHAD.)

Due to the lens used or the environmental condition, vertical color shading may occur at the top and bottom of the screen. In this case, the shading correction can decrease the color shading. For the shading correction of the unit, MANU (Manual shading correction) and OFF (no shading correction) modes are provided.

1MANU (Manual Shading)

Adjust the correction amount on the PROCESS menu by confirming with a monitor or a waveform monitor.

2OFF

The status is no shading correction.

*The shading correction is effective when the lens iris or zoom ratio is fixed. Use the unit with SHAD. OFF for variable lens conditions.

Move up down by pushing

MENU UP, DOWN

Select the desired value by pushing

DATA UP, DOWN

 

 

-- PROCESS --

 

 

 

 

 

• Gamma correction ON/OFF

 

 

GAMMA

OFF

 

 

 

• Master pedestal adjustment -64 to 64

 

 

 

 

 

• R pedestal adjustment

-64 to 64

 

 

M.PED

0

 

 

 

 

 

 

 

 

R.PED

0

 

 

 

 

• B pedestal adjustment

-64 to 64

 

 

 

 

 

B.PED

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHAD.

MANU

 

 

 

 

• Shading mode setting

MANU/OFF

 

 

 

 

 

 

MANU

0

 

 

 

 

 

 

 

 

 

 

• Manual shading adjustment -128 to 127

(4. 1) Changing gamma correction

1Move the "→" to GAMMA by pushing [MENU UP], [MENU DOWN] buttons.

2Select the gamma correction by pushing [DATA UP], [DATA DOWN] buttons.

(4. 2) Changing master pedestal

1Move the "→" to M. PED by pushing [MENU UP], [MENU DOWN] buttons.

2Adjust the master pedestal by pushing [DATA UP], [DATA DOWN] buttons.

(4. 3) Changing R pedestal

1Move the "→" to R. PED by pushing [MENU UP], [MENU DOWN] buttons.

2Adjust the R pedestal by pushing [DATA UP], [DATA DOWN] buttons.

(4. 4) Changing B pedestal

1Move the "→" to B. PED by pushing [MENU UP], [MENU DOWN] buttons.

2Adjust the B pedestal by pushing [DATA UP], [DATA DOWN] buttons.

22

Image 22
Contents IK-TF5U Following information is only for EU-member statesSafety Precautions Disclaimer Avoid placing in humid, smoky, vaporized or dusty placesTable of Contents Components Names and Functions Connection Connector Pin AssignmentsStandard Connection Automatic Black Balance OperationWhite Balance Result displayed Meaning Temp LOWShading Correction GainOFF Items Controlled by the Screen Display Available selectionsUsing the Menus Mode Setting by the Screen DisplayDisp Manual MenusShutter Electronic shutter Flicker may be largePartial scanning setting Changing the setting in Manu modeMode = Manual Menu UP, Down Data UP, DownMode = SS Changing the setting in SS synchro. scan modeChanging the shutter speed setting Changing the polarity of inputting trigger pulse setting Changing the setting in E.TRG modeChanging the setting in 1P SNR mode Changing 1P SNR exposure time settingMode = E.TRG E.TRG = 1P SR Changing the setting in 1P SR modeChanging 1P SR exposure time setting Changing the setting in PW SNR mode Mode = E.TRG E.TRG = PW SNR Mode = E.TRG E.TRG = PW SR Changing the setting in PW SR mode Mode = E.TRG E.TRG = RR Changing the gain in Manu mode Changing the setting in GainGain Video gain WHT BAL White balance Changing master pedestal MANU/OFFChanging gamma correction Changing R pedestalSync OptionSetting by 1H Setting by the frameReturning to factory settings Synchro. Scan OperationE. TRG External trigger 1P SNR 1 Pulse Trigger Sync Non Reset1 Pulse Trigger SYNC-NON Reset Picture Output Timing Fval Lval Dval1P SR 1 Pulse Trigger Sync Reset 1 Pulse Trigger SYNC-RESET Picture Output TimingPW SNR Pulse width trigger SYNC-NON Reset Pulse Width Trigger SYNC-NON Reset Picture Output TimingPW SR Pulse width trigger SYNC-RESET 1 Pulse Width Trigger SYNC-RESET Picture Output TimingInput Timing Chart Example RR Reset restartLong Term Exposure Partial Scanning OFF All pixels scanning When Partial Scanning Mode is onPartial Read Partial Scanning onExternal Sync External sync signal polarityUsing the unit with external sync signal External sync frequency rangeInput Output Signal Specificatoins Horizontal Output Waveform Timing Chart CCD Output Waveform Timing ChartVertical Output Waveform Timing Chart Specifications RGB, 3CCDBefore Making a Service Call External Appearance DiagramSymptom Items to be checked How to Obtain Warranty Service Step-By-Step Procedures Limited Warranty Toshiba CCD CameraOne 1 Year Limited Warranty of Labor and Parts Your Responsibilities