Toshiba IK-TF5U Synchro. Scan Operation, Setting by the frame, Returning to factory settings

Page 24

( 7 ) Returning to factory settings

All the settings can be returned to the factory default status (preset status).

(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.

(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.

(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.

7. 3 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1H/525H ~ 524H/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 s). When operating Partial Scannig, the number’s listed below can be used for setting.

Partial scanning OFF

1H/525H ~ 524H/525H

90fps, E90fps

1H/348H ~ 347H/348H

115fps, E115fps

1H/272H ~ 271H/272H

120fps, E120fps

1H/262H ~ 261H/262H

160fps, E160fps

1H/197H ~ 196H/197H

180fps, E180fps

1H/175H ~ 174H/175H

240fps, E240fps

1H/131H ~ 130H/131H

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DAVL

n

n+1

(4FRM setting)

24

Image 24
Contents IK-TF5U Following information is only for EU-member statesSafety Precautions Disclaimer Avoid placing in humid, smoky, vaporized or dusty placesTable of Contents Components Names and Functions Connector Pin Assignments ConnectionStandard Connection Operation Automatic Black BalanceWhite Balance Result displayed Meaning Temp LOWGain Shading CorrectionOFF Items Controlled by the Screen Display Available selectionsMode Setting by the Screen Display Using the MenusDisp Menus Shutter Electronic shutterManual Flicker may be largeChanging the setting in Manu mode Mode = ManualPartial scanning setting Menu UP, Down Data UP, DownChanging the setting in SS synchro. scan mode Mode = SSChanging the shutter speed setting Changing the setting in E.TRG mode Changing the setting in 1P SNR modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingChanging the setting in 1P SR mode Mode = E.TRG E.TRG = 1P SRChanging 1P SR exposure time setting Changing the setting in PW SNR mode Mode = E.TRG E.TRG = PW SNRChanging the setting in PW SR mode Mode = E.TRG E.TRG = PW SRMode = E.TRG E.TRG = RR Changing the setting in Gain Changing the gain in Manu modeGain Video gain WHT BAL White balance MANU/OFF Changing gamma correctionChanging master pedestal Changing R pedestalSync OptionSetting by the frame Returning to factory settingsSetting by 1H Synchro. Scan Operation1P SNR 1 Pulse Trigger Sync Non Reset 1 Pulse Trigger SYNC-NON Reset Picture Output TimingE. TRG External trigger Fval Lval Dval1P SR 1 Pulse Trigger Sync Reset 1 Pulse Trigger SYNC-RESET Picture Output TimingPW SNR Pulse width trigger SYNC-NON Reset Pulse Width Trigger SYNC-NON Reset Picture Output TimingPW SR Pulse width trigger SYNC-RESET 1 Pulse Width Trigger SYNC-RESET Picture Output TimingRR Reset restart Input Timing Chart ExampleLong Term Exposure When Partial Scanning Mode is on Partial ReadPartial Scanning OFF All pixels scanning Partial Scanning onExternal sync signal polarity Using the unit with external sync signalExternal Sync External sync frequency rangeInput Output Signal Specificatoins CCD Output Waveform Timing Chart Horizontal Output Waveform Timing ChartVertical Output Waveform Timing Chart Specifications RGB, 3CCDExternal Appearance Diagram Before Making a Service CallSymptom Items to be checked Limited Warranty Toshiba CCD Camera One 1 Year Limited Warranty of Labor and PartsHow to Obtain Warranty Service Step-By-Step Procedures Your Responsibilities