( 7 ) Returning to factory settings
All the settings can be returned to the factory default status (preset status).
(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.
7. 3 Synchro. Scan Operation
The shutter speed can be set by the horizontal scanning period (1H) or by the frame.
( 1 ) Setting by 1H
1H/525H ~ 524H/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 ∝s). When operating Partial Scannig, the number’s listed below can be used for setting.
Partial scanning OFF | 1H/525H ~ 524H/525H |
90fps, E90fps | 1H/348H ~ 347H/348H |
115fps, E115fps | 1H/272H ~ 271H/272H |
120fps, E120fps | 1H/262H ~ 261H/262H |
160fps, E160fps | 1H/197H ~ 196H/197H |
180fps, E180fps | 1H/175H ~ 174H/175H |
240fps, E240fps | 1H/131H ~ 130H/131H |
( 2 ) Setting by the frame
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.
(Internal VD)
RGB data (video interval image)
FVAL
LVAL,
DAVL
n
n+1
(4FRM setting)