7. 6 External Sync

When using the unit with an external sync signal, input HD and VD to CC3 and CC4 of the DIGITAL terminal. When the external sync signal is input, the camera automatically switches its sync from the internal sync to the external sync.

The operation is as shown below, depending on the unit's status and how external sync signals are input.

Shutter mode

HD input

VD input

Note

At time of SYNC-NON

N

N

Internal sync mode

RESET mode

Y

Y

External sync mode

 

N

Y

Only V reset is applied due to VD input. Normally not used.

 

Y

N

HD is synchronized to external, but video is not output

 

 

 

because there is no VD input. Normally not used.

At time of SYNC-RESET

N

*

Internal sync mode. The presence of VD is ignored, and after

mode

 

a specified time after a trigger input, V reset is applied.

 

Y

*

HD is synchronized to external. The presence of VD is

 

 

ignored, and after a specified time after a trigger input, V

 

 

 

reset is applied.

At time of reset restart

Y

Y

HD is synchronized to external. Video is output due to VD

 

 

 

input.

 

N

Y

HD is synchronized to the inside of the camera. Video is

 

 

 

output due to VD input.

 

*

N

Video is not output because there is no VD input. Normally

 

 

not used.

At time of manual

N

N

Internal sync mode

shutter

Y

Y

External sync mode

 

Y

N

HD is synchronized to external. Normally not used.

 

N

Y

Disabled

*Either Y or N is permitted.

( 1 ) External sync signal polarity

HD: 2 to 5V(p-p)

Negative

VD: 2 to 5V(p-p)

Negative

( 2 ) External sync frequency range

(External sync with HD, VD)

Within ±1% (at horizontal sync frequency of 31.469 kHz)

( 3 ) Using the unit with external sync signal

When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase".

(3. 1) H (horizontal) phase adjustment

Observe the external sync signal and the LVAL signal output waveform of the unit with a dual trace oscilloscope, and ad- just H phase so that the H phases match.

External

Sync. signal Match

the phase.

LVAL signal output

31

Image 31
Contents Following information is only for EU-member states IK-TF5USafety Precautions Avoid placing in humid, smoky, vaporized or dusty places DisclaimerTable of Contents Components Names and Functions Connection Connector Pin AssignmentsStandard Connection Automatic Black Balance OperationWhite Balance Temp LOW Result displayed MeaningShading Correction GainOFF Available selections Items Controlled by the Screen DisplayUsing the Menus Mode Setting by the Screen DisplayDisp Flicker may be large MenusShutter Electronic shutter ManualMenu UP, Down Data UP, Down Changing the setting in Manu modeMode = Manual Partial scanning settingMode = SS Changing the setting in SS synchro. scan modeChanging the shutter speed setting Changing 1P SNR exposure time setting Changing the setting in E.TRG modeChanging the setting in 1P SNR mode Changing the polarity of inputting trigger pulse settingMode = E.TRG E.TRG = 1P SR Changing the setting in 1P SR modeChanging 1P SR exposure time setting Mode = E.TRG E.TRG = PW SNR Changing the setting in PW SNR modeMode = E.TRG E.TRG = PW SR Changing the setting in PW SR modeMode = E.TRG E.TRG = RR Changing the gain in Manu mode Changing the setting in GainGain Video gain WHT BAL White balance Changing R pedestal MANU/OFFChanging gamma correction Changing master pedestalOption SyncSynchro. Scan Operation Setting by the frameReturning to factory settings Setting by 1HFval Lval Dval 1P SNR 1 Pulse Trigger Sync Non Reset1 Pulse Trigger SYNC-NON Reset Picture Output Timing E. TRG External trigger1 Pulse Trigger SYNC-RESET Picture Output Timing 1P SR 1 Pulse Trigger Sync ResetPulse Width Trigger SYNC-NON Reset Picture Output Timing PW SNR Pulse width trigger SYNC-NON Reset1 Pulse Width Trigger SYNC-RESET Picture Output Timing PW SR Pulse width trigger SYNC-RESETInput Timing Chart Example RR Reset restartLong Term Exposure Partial Scanning on When Partial Scanning Mode is onPartial Read Partial Scanning OFF All pixels scanningExternal sync frequency range External sync signal polarityUsing the unit with external sync signal External SyncInput Output Signal Specificatoins Horizontal Output Waveform Timing Chart CCD Output Waveform Timing ChartVertical Output Waveform Timing Chart RGB, 3CCD SpecificationsBefore Making a Service Call External Appearance DiagramSymptom Items to be checked Your Responsibilities Limited Warranty Toshiba CCD CameraOne 1 Year Limited Warranty of Labor and Parts How to Obtain Warranty Service Step-By-Step Procedures