8. INPUT OUTPUT SIGNAL SPECIFICATOINS

( 1 ) HD Input Specifications

( 2 ) VD Input Specifications

2.0s 5.0s

5H 21H

( 3 ) Trigger Pulse Specifications

More than 2 s

(Positive polarity mode)

More than 2 s

(Negative polarity mode)

( 4 ) External HD/VD Input Phase Specifications

External HD rising edge

100

External HD

100

Unit : Clock

1 clk=40.74nsec

Center

The phase relationship of the external HD and VD should correspond to the center phase (i.e., the external HD falling edge) as illustrated in the above diagram.

External VD falling edge:

Please input within about 100 clock cycles of the standard center phase.

Note that V sync of the video is output with a delay of about 2H from the external VD at the time of reset-restart and the external trigger mode.

In the normal mode:

Continuously with the HD period of 31.78 µs and VD period of 16.68 ms (partial scanning 90fps: 11.06 ms, 115fps:

8.64 ms, 120fps: 8.33 ms, 160fps: 6.26 ms, 180fps: 5.56 ms, 240fps: 4.16 ms).

Phase timing is as illustrated in the above diagram (with only the falling edge applicable).

In the reset-restart/external trigger mode:

Continuously with the HD period of 31.78 µs. VD (reset) is at an arbitrary timing with the phase of HD being within the standard of the above diagram.

32

Image 32
Contents IK-TF5U Following information is only for EU-member statesSafety Precautions Disclaimer Avoid placing in humid, smoky, vaporized or dusty placesTable of Contents Components Names and Functions Standard Connection Connector Pin AssignmentsConnection White Balance OperationAutomatic Black Balance Result displayed Meaning Temp LOWOFF GainShading Correction Items Controlled by the Screen Display Available selectionsDisp Mode Setting by the Screen DisplayUsing the Menus Menus Shutter Electronic shutterManual Flicker may be largeChanging the setting in Manu mode Mode = ManualPartial scanning setting Menu UP, Down Data UP, DownChanging the shutter speed setting Changing the setting in SS synchro. scan modeMode = SS Changing the setting in E.TRG mode Changing the setting in 1P SNR modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingChanging 1P SR exposure time setting Changing the setting in 1P SR modeMode = E.TRG E.TRG = 1P SR Changing the setting in PW SNR mode Mode = E.TRG E.TRG = PW SNRMode = E.TRG E.TRG = RR Changing the setting in PW SR modeMode = E.TRG E.TRG = PW SR Gain Video gain Changing the setting in GainChanging the gain in Manu mode WHT BAL White balance MANU/OFF Changing gamma correctionChanging master pedestal Changing R pedestalSync OptionSetting by the frame Returning to factory settingsSetting by 1H Synchro. Scan Operation1P SNR 1 Pulse Trigger Sync Non Reset 1 Pulse Trigger SYNC-NON Reset Picture Output TimingE. TRG External trigger Fval Lval Dval1P SR 1 Pulse Trigger Sync Reset 1 Pulse Trigger SYNC-RESET Picture Output TimingPW SNR Pulse width trigger SYNC-NON Reset Pulse Width Trigger SYNC-NON Reset Picture Output TimingPW SR Pulse width trigger SYNC-RESET 1 Pulse Width Trigger SYNC-RESET Picture Output TimingLong Term Exposure RR Reset restartInput Timing Chart Example When Partial Scanning Mode is on Partial ReadPartial Scanning OFF All pixels scanning Partial Scanning onExternal sync signal polarity Using the unit with external sync signalExternal Sync External sync frequency rangeInput Output Signal Specificatoins Vertical Output Waveform Timing Chart CCD Output Waveform Timing ChartHorizontal Output Waveform Timing Chart Specifications RGB, 3CCDSymptom Items to be checked External Appearance DiagramBefore Making a Service Call Limited Warranty Toshiba CCD Camera One 1 Year Limited Warranty of Labor and PartsHow to Obtain Warranty Service Step-By-Step Procedures Your Responsibilities