| 73 |
Control System Menu |
Common Control I/O
COMMON CONTROL
1 | Control | 1 | Any | Zone | On |
2 | Control 2 | Any | Zone | On | |
3 | Flasher Out Selected Input | ||||
4 | IR to flasher out | Off | |||
| control out 1 will be on | ||||
| when any zone is on |
| |||
| ↑↓ next item |
| adjust | ←→ |
MENU setup control
The CT610/602 is equipped with two 12VDC 200mA common control voltages. They are programmed at the factory to turn on when any Zone is powered on. Note, CT310/300 has one 12VDC 200mA common control.
1.Use the Up/Down keys to select the Control Out you wish to program. This will assign operation to the “CTRL OUT” located in the common control section on the bottom of the control cards.
2.Use the Left/Right keys to pick from the available options.
3.Use the Menu button to exit to the previous menu.
Specifications for the common control settings can be found on page 48.
| COMMON CONTROL |
|
| |
1 | Control 1 | Any | Zone | On |
2 | Control 2 | Any | Zone | On |
3 Flasher Out Selected Input | ||||
4 | IR to flasher out | Off | ||
| control out 1 will be on | |||
| when any zone is on |
| ||
| ↑↓ next item |
| adjust | ←→ |
MENU setup control
Flasher Out
(IR Routing for Identical Components)
Flasher Output
Below are the three possible choices for the 9 IR outputs:
Off - All flashers are off for troubleshooting purposes. No IR data will transmit out the 9 IR outputs.
Selected Input - IR commands are routed from each Zone to the selected source of that zone. This allows identical source components to be used independently in the system.
For example, if someone in Zone A is listening to a Brand X CD player connected to Input 5, all IR commands from Zone A are routed ONLY to Input 5. At the same time, in Zone B, someone is listening to a second iden- tical Brand X CD player connected to Input 6. All IR commands from Zone B are routed ONLY to Input 6. IR routing follows the zone(s) audio input only.
All Inputs - All flash / simultaneous flash. IR commands from any zone are routed to all flashers regardless of what input the zone(s) is on.
B & K