B&K CT310, CT600, CT602, CT300 user manual Basic Expanded System Using a CT-1, CT610 #3 CT610 #2

Page 32

28

CT-1 Expansion

 

Basic Expanded System Using a CT-1

Up to 18 stereo zones can be added using a single CT-1. A basic expanded system consists of one, two or three CT Receivers, up to nine shared sources, one CT-1 and one Home Theater product. A basic system can require the use of one CT-1, it allows up to three CT Receivers (or 18 stereo zones) to communicate with one another while also sharing and communicating with common sources. The following diagrams depict how a basic system is connected. When connecting multiple CT Receivers to the CT-1, always connect all nine emitters to insure proper IR routing.

CT610 #3

Attach to front panel*

CT610 #2

Attach to front panel*

*Attach to front panel

Sources

CT610 #1

Each CT Receiver needs to be provided with an emitter attached to the front panel. This emitter allows IR to be sent back to any of the CT Receivers in this system, thus allowing keypads from any CT Receivers to con- trol any or all of these 18 zones.

CT610 #3

 

 

CT610 #2

B & K C o m p o n e n t s , L t d . C T 6 1 0

6 Z o n e R e c e i v e r

B & K C o m p o n e n t s , L t d . C T 6 1 0

6 Z o n e R e c e i v e r

Headphone

Sleep

Preset

Enter

Save

Down

Up

Source

Menu

Zone

Power

On/Off

Headphone

Sleep

Preset

Enter

Save

Down

Up

Source

Menu

Zone

Power

On/Off

CT IN MASTER

 

HOME THEATER

 

 

 

 

 

 

CT 3 IR FLASHER IN / [ CHAIN OUT ]

 

 

 

 

 

 

 

CT 2 FLASHER IN

 

 

 

 

+12V GND RCV

 

S E R I A L #

 

 

+12V

D IN

GND

IN

9

8

7

6

5

4

3

2

1

[ OUT ]

9

8

7

6

5

4

3

2

1

OUT

NC

NC

 

ROUTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232

 

SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XMIT

1

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

9

8

7

6

5

4

3

2

1

CHAIN

9

8

7

6

5

4

3

2

1

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

FLASHER OUT

 

 

 

IN

 

 

 

 

CT 1 FLASHER IN

 

 

 

 

Note: IR data from the CT-1 needs to be communi- cated using the front panel of the CT receiver. IR Data IN on the back panel should not be used.

CT610 #1

B & K C o m p o n e n t s , L t d . C T 6 1 0

6 Z o n e R e c e i v e r

Headphone

Sleep

Preset

Enter

Save

Down

Up

Source

Menu

Zone

Power

On/Off

B & K

S I M P LY B E T T E R !

Image 32
Contents 13226 Accessories Included Parts and Accessories Guide Installation and System DiagramsSetup Using a PC and BKcSuite BKcSuite Setup and OverviewSpecifications On Screen Main MenuFinesse and Power To Please a Household Introduction / OverviewCT Receiver Features and Benefits CK1.2 Keypad Features and Benefits Point Any Remote Control at the KeypadCK1.2 Keypad Features and Benefits Status Feedback to KeypadsParts and Accessories Guide CT Receiver Front Panel CT602/600/300CT Receiver Back Panel S ECK1.2 Front Panel / Back Panel Programming Jack Behind the FaceplateMZ-128 Remote Control CT-1 System Integrator P/N RJ-45 to 5 position Phoenix Adapter P/NDB-9 to RJ-45 Adapter P/N13290 BK Toolbox CD-ROM P/NInstallation and System Diagrams Installation and System DiagramsBasic System Hookup Placement and Ventilation Default OperationInstallation Considerations Connection StrategyAC Power and Line Fuse Accommodate up to 12-gauge wireSpeaker Connections for CT Receiver Speaker Connections CT310Example CT Receiver Six Zone Speaker Connections CT Receiver Speaker ConnectionsKeypad Connections Example connection of a CK1.2 KeypadCT Receiver cannot receive RS-232 via this terminal CK1.2 Keypad ConnectionsCommon Ground Adding Additional Keypads in the Same Zone Left Control CardShared Source Connections CT Receiver ConnectionIR Emitter Outputs IR Flasher Emitter OutputBuffered Outputs Zone Line Outputs Zone Line OutputsFixed Output / Variable Output Changing Line Level Outputs From Fixed to VariableDedicated Source Inputs Local Local IR Source Control Local Source IR ControlCommon Control Triggers Common Control TriggersCT Receiver Common Control Connection and Trigger Factory Reset RF RemoteAM Loop Antenna FM AntennaSystem Expansion System ExpansionConnecting Two CT Receivers Coupling Two CT Receivers Maximum 12 Stereo ZonesSwap Cable Between Two CT Receivers Should not be connected between RJ- 45 jacksAdding a 7th Zone Using The AVR507/505/50 Second Zone Seventh Zone Connection Diagram No identicalAdding a 7th Zone SourcesSwap Cable Construction CT-1 IR Routing System IntegratorCAT5 T568B Swap Cable RS-232 Swap CableBasic Expanded System Using a CT-1 CT610 #3 CT610 #2CT-1 Expansion Source Control Using a CT-1CT-1 Power Connection 12VDC Adding a Home Theater RS-232 ConnectionUsing a Swap Cable to Control a Theater Setup Using a PC and BKcSuite Setup Using a PC and BKcSuiteConnection to a PC CT Receiver ConnectionComputer Connection USB to Serial AdapterBKcSuite Setup and Overview BKcSuite Setup and OverviewBKcSuite Task Bar Explained BKcSuite Task Bar ExplainedBasic Setup Menu Basic Setup MenuAdvanced Full Setup Menu Advanced Setup MenuHardware Zone Settings Tab Fixed or Variable Levels for Stereo Zones Maximum Level Limits the Output whether Fixed or VariableLeft and Right Level Calibration Fixed or Variable Levels for Mono ZonesSplitting a Zone To Mono Sub-ZoningCode-Set Description and Overview Code-Set Description and OverviewGroups / Code Sets / Zones Tab M P LY B E T T E R Input Settings To Compensate Levels Input Settings TabShared Source Input Names Dedicated Source Input NamesPower On Titles Tab Select Power On Setting Power On PreferencePower-On Preferences Tab Select Code SetInput Mode Selection ModeInput Configuration Tab Release Time/ Event Tab ActionActivated By Level EventDisplay Tab Front Panel BrightnessIndividual Zone Display Zone Control Zone Control OutHeadphone 12V Control TabZone Rear Data In Setting IR Flasher Settings TabFlasher Outputs Front Panel IR to Flasher OutputsSetup Menu Visible Front Panel ButtonsFront Panel IR Memory LockedRS-232 Port Enable RS-232 Echo EnabledBaud Rate RS-232 Receive & Transmit IDV2.0 Enabled RS-232 Feedback Selection Continuous ReplyConvert IR to BKC-DIP Messages Transmit BKC-DIP to ZonesRecall Volume In Preset Favorite Preset RecallPreset Operation Tab Auto NamingKeypad Feedback Tab Preset Editor Preset Editor Features and BenefitsOpening the Preset Editor Preset Editor Window Editing PresetsRS-232 Serial Macro Editor RS-232 Serial Macro EditorCK1.2 Keypad CK1.2 KeypadSetup Using the On Screen Display Setup Using the On Screen DisplayOn Screen Menu Tree Diagram CT Receiver On Screen Display Menu Structure OSDOn Screen Menu Operation with the MZ-128 Using a Remote ControlUsing The Remote Control and On-Screen Menus Front Panel Buttons CT610 / CT310CT602 / CT300 No front panel operation Main Menu On Screen Main MenuZone Favorite Presets Menu Zone OperationAudio/Video System Setup Inputs Sub-MenuNaming an Input Main Menu Sub-menu’sAudio / Video Submenu Zone Menu when set to MonoMenu Items for a Dedicated Input Zone Power On Settings Page/Event SetupControl Menu Setup Display SetupZone Code-Sets/Names and Group Titles Control System MenuZone Code-Sets/Groups and Group Titles Code SetCommon Control I/O Flasher OutIR Routing for Identical Components Flasher OutputIR to Flasher Out Presets Setup Power On TitlesPreset Volume Preset NamesRS-232 Options Control System SetupSecurity Options Memory Backup Setup RS-232 Slave ControlMain Menu Setup System Status# of Volume Controls Zone Planning WorksheetsInput Planning Worksheet CT Receiver Input PlanningCable Calculation Source Distance for Home Run Total Project Manager Date CT Receiver Preferences and PresetsPower On Preferences and Presets Problem Possible Solution Troubleshooting Guide For BKcSuiteTroubleshooting Guide for CT Receivers Limited Warranty Returning EquipmentSpecifications CT610/602 CT600 CT310 CT300