B&K CT602 user manual Specifications, CT610/602 CT600 CT310 CT300

Page 88

Specifications

Multi-Zone Receivers

Specifications

 

CT610/602

CT600

CT310

CT300

 

 

 

 

 

 

Number of Zones

 

6 Stereo

6 Stereo

3 Stereo

3 Stereo

 

12 Mono

12 Mono

6 Mono

6 Mono

 

 

 

 

 

 

 

 

Internal AM / FM Tuner

 

2

1

2

1

Power Rating @ 8

 

All Zones

All Zones

Zone A =150 Watts

All Zones

(4stable all Ch driven)

 

55 Watts / Ch

55 Watts / Ch

Zones B-C = 55 Watts

55 Watts / Ch

 

 

 

 

 

 

Signal To Noise Ratio

 

89 dB

89 dB

89 dB

89 dB

Audio Frequency Response

 

20 Hz - 20 kHz

20 Hz - 20 kHz

20 Hz - 20 kHz

20 Hz - 20 kHz

Audio Source Inputs

 

9 (RCA)

9 (RCA)

9 (RCA)

9 (RCA)

Audio Loop Outputs (Buffered)

9 (RCA)

9 (RCA)

9 (RCA)

9 (RCA)

Audio Buffered Output Impedance

220

220

220

220

Video Freq. Response - Composite

20 Hz - 10 MHz

20 Hz - 10 MHz

20 Hz - 10 MHz

20 Hz - 10 MHz

Video Source Input Impedance

75

75

75

75

Video Source Inputs

 

9 Composite

9 Composite

9 Composite

9 Composite

Video Loop Outputs (Buffered)

9 Composite

9 Composite

9 Composite

9 Composite

Video Output Impedance (Buffered)

75

75

75

75

Dedicated Zone AV Inputs

 

6 (RCA)

6 (RCA)

3 (RCA)

3 (RCA

Zone Line AV Outputs

 

6 (RCA)

6 (RCA)

3 (RCA)

3 (RCA)

IR Source Control Flasher Outputs

9

9

9

9

(3.5mm mono)

(3.5mm mono)

(3.5mm mono)

(3.5mm mono)

 

 

 

 

 

 

 

 

IR Flasher Voltage

 

5V with 475

5V with 475

5V with 475

5V with 475

 

in-series

in-series

in-series

in-series

 

 

 

 

 

 

 

 

Headphone Output

 

Yes

No

Yes

No

Front Panel Control

 

Yes

IR only

Yes

IR only

 

(CT602: No)

 

 

 

 

 

Front Display Type

 

VFD Alphanumeric

LED Power

VFD

LED Power

 

(CT602: No)

Indicator

Alphanumeric

Indicator

 

 

 

 

Yes

Yes

Yes

Yes

RS-232 Device Control

 

Triggerable

Triggerable

Triggerable

Triggerable

 

 

by IR

by IR

by IR

by IR

IR Zone Data Inputs

 

6

6

3

3

12 Volt Control / Status Outputs

6

6

3

3

Common Control Inputs

 

2

2

1

1

Common Control Outputs

 

2

2

1

1

Whole House Presets

 

100

100

100

100

Overall Dimensions

Height

7.50” (7.62”)

7.50” (7.62”)

7.50” (7.62”)

7.50” (7.62”)

(Cutout Dimensions)

Width

17.00” (17.12”)

17.00” (17.12”)

17.00” (17.12”)

17.00” (17.12”)

 

Depth

15.50” (16.62”)

15.50” (16.62”)

15.50” (16.62”)

15.50” (16.62”)

Shipping Weight

 

55 lbs.

55 lbs.

55 lbs.

55 lbs.

 

 

 

 

 

 

CT Receiver_Manual_0905.pdf

Image 88
Contents 13226 Accessories Included Parts and Accessories Guide Installation and System DiagramsSetup Using a PC and BKcSuite BKcSuite Setup and OverviewSpecifications On Screen Main MenuFinesse and Power To Please a Household Introduction / OverviewCT Receiver Features and Benefits CK1.2 Keypad Features and Benefits Point Any Remote Control at the KeypadCK1.2 Keypad Features and Benefits Status Feedback to KeypadsParts and Accessories Guide CT Receiver Front Panel CT602/600/300CT Receiver Back Panel S ECK1.2 Front Panel / Back Panel Programming Jack Behind the FaceplateMZ-128 Remote Control CT-1 System Integrator P/N RJ-45 to 5 position Phoenix Adapter P/NDB-9 to RJ-45 Adapter P/N13290 BK Toolbox CD-ROM P/NInstallation and System Diagrams Installation and System DiagramsBasic System Hookup Placement and Ventilation Default OperationInstallation Considerations Connection StrategyAC Power and Line Fuse Accommodate up to 12-gauge wireSpeaker Connections for CT Receiver Speaker Connections CT310Example CT Receiver Six Zone Speaker Connections CT Receiver Speaker ConnectionsKeypad Connections Example connection of a CK1.2 KeypadCommon Ground CK1.2 Keypad ConnectionsCT Receiver cannot receive RS-232 via this terminal Adding Additional Keypads in the Same Zone Left Control CardShared Source Connections CT Receiver ConnectionBuffered Outputs IR Flasher Emitter OutputIR Emitter Outputs Zone Line Outputs Zone Line OutputsDedicated Source Inputs Local Changing Line Level Outputs From Fixed to VariableFixed Output / Variable Output Local IR Source Control Local Source IR ControlCT Receiver Common Control Connection and Trigger Common Control TriggersCommon Control Triggers Factory Reset RF RemoteAM Loop Antenna FM AntennaSystem Expansion System ExpansionConnecting Two CT Receivers Coupling Two CT Receivers Maximum 12 Stereo ZonesSwap Cable Between Two CT Receivers Should not be connected between RJ- 45 jacksAdding a 7th Zone Using The AVR507/505/50 Second Zone Seventh Zone Connection Diagram No identicalAdding a 7th Zone SourcesSwap Cable Construction CT-1 IR Routing System IntegratorCAT5 T568B Swap Cable RS-232 Swap CableBasic Expanded System Using a CT-1 CT610 #3 CT610 #2CT-1 Power Connection 12VDC Source Control Using a CT-1CT-1 Expansion Adding a Home Theater RS-232 ConnectionUsing a Swap Cable to Control a Theater Setup Using a PC and BKcSuite Setup Using a PC and BKcSuiteConnection to a PC CT Receiver ConnectionComputer Connection USB to Serial AdapterBKcSuite Setup and Overview BKcSuite Setup and OverviewBKcSuite Task Bar Explained BKcSuite Task Bar ExplainedBasic Setup Menu Basic Setup MenuAdvanced Full Setup Menu Advanced Setup MenuHardware Zone Settings Tab Fixed or Variable Levels for Stereo Zones Maximum Level Limits the Output whether Fixed or VariableLeft and Right Level Calibration Fixed or Variable Levels for Mono ZonesSplitting a Zone To Mono Sub-ZoningCode-Set Description and Overview Code-Set Description and OverviewGroups / Code Sets / Zones Tab M P LY B E T T E R Input Settings To Compensate Levels Input Settings TabShared Source Input Names Dedicated Source Input NamesPower On Titles Tab Select Power On Setting Power On PreferencePower-On Preferences Tab Select Code SetInput Mode Selection ModeInput Configuration Tab Release TimeActivated By Action/ Event Tab Level EventIndividual Zone Display Front Panel BrightnessDisplay Tab Zone Control Zone Control OutHeadphone 12V Control TabZone Rear Data In Setting IR Flasher Settings TabFlasher Outputs Front Panel IR to Flasher OutputsSetup Menu Visible Front Panel ButtonsFront Panel IR Memory LockedRS-232 Port Enable RS-232 Echo EnabledBaud Rate RS-232 Receive & Transmit IDV2.0 Enabled RS-232 Feedback Selection Continuous ReplyConvert IR to BKC-DIP Messages Transmit BKC-DIP to ZonesRecall Volume In Preset Favorite Preset RecallPreset Operation Tab Auto NamingKeypad Feedback Tab Opening the Preset Editor Preset Editor Features and BenefitsPreset Editor Preset Editor Window Editing PresetsRS-232 Serial Macro Editor RS-232 Serial Macro EditorCK1.2 Keypad CK1.2 KeypadSetup Using the On Screen Display Setup Using the On Screen DisplayOn Screen Menu Tree Diagram CT Receiver On Screen Display Menu Structure OSDUsing The Remote Control and On-Screen Menus Using a Remote ControlOn Screen Menu Operation with the MZ-128 CT602 / CT300 No front panel operation CT610 / CT310Front Panel Buttons Main Menu On Screen Main MenuZone Favorite Presets Menu Zone OperationAudio/Video System Setup Inputs Sub-MenuNaming an Input Main Menu Sub-menu’sMenu Items for a Dedicated Input Zone Menu when set to MonoAudio / Video Submenu Zone Power On Settings Page/Event SetupControl Menu Setup Display SetupZone Code-Sets/Names and Group Titles Control System MenuZone Code-Sets/Groups and Group Titles Code SetCommon Control I/O Flasher OutIR Routing for Identical Components Flasher OutputIR to Flasher Out Presets Setup Power On TitlesPreset Volume Preset NamesSecurity Options Control System SetupRS-232 Options Memory Backup Setup RS-232 Slave ControlMain Menu Setup System Status# of Volume Controls Zone Planning WorksheetsCable Calculation Source Distance for Home Run Total CT Receiver Input PlanningInput Planning Worksheet Power On Preferences and Presets CT Receiver Preferences and PresetsProject Manager Date Troubleshooting Guide for CT Receivers Troubleshooting Guide For BKcSuiteProblem Possible Solution Limited Warranty Returning EquipmentSpecifications CT610/602 CT600 CT310 CT300