JVC KY-F70 manual Connecting an MO drive unit, E20, Scsi terminal

Page 20

2. Before recording (continued)

Connecting an MO drive unit

It is possible to output image data stored in the main unit memory to an MO drive unit. ( Page 36 Saving images from the memory to an MO disk)

Dip switches

SCSI

REC

 

 

SEND AW/SEL MODE

MENU

UP DOWN SET

@ @ @ @ @ @

FREEZE

 

PLAY

MONITOR

LENS

 

REMOTE

DC IN

ON 1 2 3 4

POWER

SEE INSTRUCTION MANUAL

SCSI terminal

To directly connect the MO drive to the main unit, set the dip switches on the rear of the main unit as shown below.

ON 1 2 3 4

(SCSI : 7)

MEMO

Do not set the ID of the MO drive side to other than 7.

The image data outputted to an MO drive will be 1360 × 1024 pixels, regardless whether the monitor in use is VGA or SXGA, or whether the VGA mode is set to FINE or DRAFT.

The maximum allowed length of the SCSI cable is 3m.

When connecting an MO drive to a PC, separate setting of the SCSI ID is required. ( Page 64 7. Connecting to a PC)

It is not possible to simultaneously output the image data to a printer and MO drive.

E20

Image 20
Contents Illustration with optional lens attachment This instruction book is made from 100% recycled paperSafety Precautions Varning Table of Contents Characters and symbols used in this instruction book MemoIntroduction FeaturesAccessories and attachments Line and patterns may appear distorted when recorded Phenomena unique to CCDPart names and their functions Front and bottomRear Ventilation hole E10Mode Used to connect the lens cable Mounting the lens This lamp lights when the power of the main unit is onE11 E12 Explanation of terminalsRemoter terminal Metal 10-pin, female E13 For the power supply, always use the AA-P700 AC adapter Before recordingBasic system E14E15 AC adapterMO disk drive Model name AdapterScrews InstallE16 Female Lens remote control Mounting the lensE17 Camera head Male Thread section Mount clamp ring LensConnecting the power Clamp filter Attached power supply cableE18 AC adapterMonitor terminal Connecting a monitorE19 Connecting an MO drive unit E20Scsi Do not set the ID of the MO drive side to other thanConnecting a printer Dip switchesE21 Scsi Set the ID of the printer side to other thanMounting the camera Mounting methodChanging the camera mounting bracket position E22E23 Fall prevention wire chain 6mm Camera headFall prevention E24 Minal on the rear of the main unitSet to OFF Set to onMenu settings VGA mode settingsLens settings VGA mode and lens settings are made from the menu screenTime and date settings Time Adjust screenE26 Play menu screenE27 OK display screenMonitor adjustment Turn the main unit power on Adjust the video monitorSet using the main unit dip switches Monitor settings E28Press the Menu button to return to the normal screen Focus adjustmentE29 White balance adjustment E30REC Menu screen Menu item Set value White Balance screenAuto white operation completed E31Auto white in operation REC Menu screen White shading adjustmentE32 E33 Basic operations Recording images to the main unit memoryE34 Freeze displayReturning to the REC mode Press the Mode button to enter the Play modePlaying back images from the memory E35Saving images from the memory to an MO disk E36Set to either the Freeze or Play mode Outputting images from the memory to a printerUse a printer with an Scsi input terminal E37Video Memory Clear Clearing images from the memoryE38 E39 Memory clearedE40 Various recording methodsRecording a PC monitor E41 System Setting screenOutputting negative images Timing chart Sxga mode Synchronizing flash and FreezeE42 High speed shutter onlyAbout ALC and EEI operations E43E44 Menu screen settingsMenu screen flow E45 Exposure screenFreeze screen Process screenSetting procedure REC normal menu screenE46 REC normal menu screen Menu item Set valueAbout the submenu screens of the normal REC menu Play menu screenREC quick menu screen E47Exposure screen E48E49 E50 White Balance screen E51Mode OFF E52Shading Level GE53 Freeze screenProcess 1/3 screen @ADJUST set when changing the gamma curve E54Gamma Used to set whether the gamma curve to determineProcess 2/3 screen E55Flare R Flare BE56 ColorMatrix Standard valueSystem Setting screen E57E58 Menu screen of the Play mode E59Send Prioryty Video ME.MORYREC mode quick menu screen E60Menu item TorE61 Sensitivity can be changed using the Level Submenu itemSensitivity can be changed when the sensitivity mode Resetting settings Menu Reset screen SET buttonResetting E62E63 Press the Menu once more to return to the normal screenConnecting to a PC Camera remote control softwareCompatible systems E64AC adapter Analog RGB, WEN, Hs, Vs, RS-232C Printer Flash Freeze switchE65 E66 SpecificationsOthers Inch screw External dimensions unit mmE67 SL96172