JVC KY-F70 manual E54, Gamma, Used to set whether the gamma curve to determine, Master Black

Page 54

6. Menu screen settings (continued)

PROCESS (1/3) screen (continued)

 

Menu item

Function/variable range

Default value

 

 

 

 

GAMMA

Used to set whether the gamma curve to determine the

NORMAL

 

 

reproduction of black is to be set using the standard value

 

 

 

or available for change.

 

 

 

NORMAL: the gamma curve is set using the standard

 

 

 

value (0.45)

 

@ @ @ @ @

@ADJUST: set when changing the gamma curve

 

 

LEVEL

The gamma curve can be adjusted only when GAMMA is

0.45

 

 

set to ADJUST.

 

 

 

Increase the number: improves the reproduction of

 

 

 

black. However, the reproduction

 

 

 

quality of bright areas becomes

 

 

 

lower.

 

 

 

Decrease the number: improves the reproduction of

 

 

 

bright areas. However, the repro-

 

 

 

duction quality of black becomes

 

 

 

lower.

 

 

 

[Variable range: 0.35 ~ 1.00 (21 steps)]

 

 

 

 

 

MASTER BLACK

Used to adjust the pedestal level (master black), which is

0

 

 

the standard black during lens cap. To view black areas,

 

 

 

increase the pedestal level to brighten the entire screen.

 

 

 

Increase the pedestal level: increase the number

 

 

 

Decrease the pedestal level: decrease the number

 

 

 

[Variable range: –99 ~ 99]

 

 

 

 

 

E54

Image 54
Contents Illustration with optional lens attachment This instruction book is made from 100% recycled paperSafety Precautions Varning Table of Contents Characters and symbols used in this instruction book MemoFeatures Accessories and attachmentsIntroduction Line and patterns may appear distorted when recorded Phenomena unique to CCDPart names and their functions Front and bottomRear E10 ModeVentilation hole This lamp lights when the power of the main unit is on E11Used to connect the lens cable Mounting the lens Explanation of terminals Remoter terminal Metal 10-pin, femaleE12 E13 Basic system For the power supply, always use the AA-P700 AC adapterBefore recording E14MO disk drive Model name E15AC adapter AdapterInstall E16Screws E17 Female Lens remote controlMounting the lens Camera head Male Thread section Mount clamp ring LensE18 Connecting the powerClamp filter Attached power supply cable AC adapterConnecting a monitor E19Monitor terminal Scsi Connecting an MO drive unitE20 Do not set the ID of the MO drive side to other thanE21 Connecting a printerDip switches Scsi Set the ID of the printer side to other thanChanging the camera mounting bracket position Mounting the cameraMounting method E22Fall prevention wire chain 6mm Camera head Fall preventionE23 Set to OFF E24Minal on the rear of the main unit Set to onLens settings Menu settingsVGA mode settings VGA mode and lens settings are made from the menu screenE26 Time and date settingsTime Adjust screen Play menu screenE27 OK display screenSet using the main unit dip switches Monitor settings Monitor adjustmentTurn the main unit power on Adjust the video monitor E28Focus adjustment E29Press the Menu button to return to the normal screen REC Menu screen Menu item Set value White balance adjustmentE30 White Balance screenE31 Auto white in operationAuto white operation completed White shading adjustment E32REC Menu screen E33 E34 Basic operationsRecording images to the main unit memory Freeze displayPlaying back images from the memory Returning to the REC modePress the Mode button to enter the Play mode E35Saving images from the memory to an MO disk E36Use a printer with an Scsi input terminal Set to either the Freeze or Play modeOutputting images from the memory to a printer E37Clearing images from the memory E38Video Memory Clear E39 Memory clearedVarious recording methods Recording a PC monitorE40 System Setting screen Outputting negative imagesE41 E42 Timing chart Sxga modeSynchronizing flash and Freeze High speed shutter onlyAbout ALC and EEI operations E43Menu screen settings Menu screen flowE44 Freeze screen E45Exposure screen Process screenE46 Setting procedureREC normal menu screen REC normal menu screen Menu item Set valueREC quick menu screen About the submenu screens of the normal REC menuPlay menu screen E47Exposure screen E48E49 E50 White Balance screen E51Shading Mode OFFE52 Level GFreeze screen Process 1/3 screenE53 Gamma @ADJUST set when changing the gamma curveE54 Used to set whether the gamma curve to determineFlare R Process 2/3 screenE55 Flare BMatrix E56Color Standard valueSystem Setting screen E57E58 Send Prioryty Menu screen of the Play modeE59 Video ME.MORYMenu item REC mode quick menu screenE60 TorSensitivity can be changed using the Level Submenu item Sensitivity can be changed when the sensitivity modeE61 Resetting Resetting settingsMenu Reset screen SET button E62E63 Press the Menu once more to return to the normal screenCompatible systems Connecting to a PCCamera remote control software E64Printer Flash Freeze switch E65AC adapter Analog RGB, WEN, Hs, Vs, RS-232C Specifications OthersE66 External dimensions unit mm E67Inch screw SL96172