EXPOSURE screen (continued)
| Menu item |
| Function/variable range |
| Default value | ||
SHUTTER | Used to set the shutter mode. |
|
|
| STEP | ||
|
| STEP: | the shutter speed can be changed using the |
| |||
|
|
| SPEED submenu item. |
|
|
| |
|
| V.SCAN: used to clear the horizontal line noise when re- |
| ||||
|
|
| cording a PC monitor by adjusting to the scan |
| |||
|
|
| speed of the monitor. |
|
|
|
|
|
|
| The shutter can be changed in detail using the |
| |||
|
|
| LEVEL submenu item. ( ☞ Page 42 Recording |
| |||
|
|
| a PC monitor) |
|
|
|
|
|
| EEI: | Used to automatically change the shutter speed |
| |||
|
|
| depending on the object brightness. |
|
| ||
|
|
| (max: 1/1920) |
|
|
|
|
|
| OFF: | • 1/30 when VGA is set to the DRAFT mode |
| |||
|
|
| • 1/7.5 when VGA is set to the FINE mode |
| |||
|
|
| • 1/7.5 when in the SXGA mode |
|
| ||
|
|
|
| ||||
| SPEED | The shutter sped can be changed when the shutter is set | STEP: 1/8 | ||||
|
| to STEP or V.SCAN. |
|
|
| V.SCAN: | |
|
| [STEP variable range: 1/1, 1/2, 1/4, 1/8, 1/15, 1/30, 1/60, | 1/30 | ||||
|
|
| 1/125, | 1/250, | 1/500, | 1/1000, |
|
|
|
| 1/2000] |
|
|
|
|
|
| [V.SCAN variable range: 1/30, ~ 1/5906. 8] |
|
|
MEMO
•In areas which the power supply frequency is 50Hz, set- ting the unit to 1/100 can reduce flickering when record- ing under florescent lighting.
•There may be shortage of light when increasing the shut- ter speed. In this case, adjust the iris or sensitivity. Spe- cial attention is required for the picture quality when rais- ing the sensitivity since images may become distorted.