4. Basic operations

Recording images to the main unit memory

The main unit is capable of storing 5 images in the VGA mode and 4 images in the SXGA mode to the main unit memory.

Exceeding the maximum number of images stored will replace the oldest image with the latest.

 

 

 

 

MODE

 

@

SCSI

@ @ @ @ @

REC LED

 

 

 

 

REC

 

 

 

 

SEND AW/SEL MODE

 

 

 

MENU

UP

DOWN SET

 

 

 

 

 

PLAY

 

 

 

 

 

FREEZE

FREEZE

 

 

 

 

 

MONITOR LENS

REMOTE

DC IN

ON 1 2 3 4

POWER

SEE INSTRUCTION MANUAL

FREE ZE

FREEZE display

1. Press the MODE button to enter the REC mode. The REC LED will light.

MEMO

The unit will automatically enter the REC mode when the power is turned on.

2. Press the FREEZE button.

Images outputted through the MONITOR terminal will become a still image and stored in the main unit memory. In addition, the REC LED will flash.

At this time, FREEZE will appear in the screen. To dis- able the message from appearing, set FRZ DISPLAY to OFF ( page 57).

MEMO

The character display contents of the monitor screen can be changed by selecting ON SCREEN in the SYSTEM SETTING screen. ( Page 57)

3. Cancel FREEZE

Press the FREEZE button once more to cancel the still image.

MEMO

It is possible to set the unit so that the still image is automati- cally cancelled after 5 seconds. Set CANCEL in the FREEZE screen to AUTO. ( Page 53)

4. Output the image to an MO drive or printer, as neces- sary.

( Pages 36 and 37)

CAUTION

Images stored in memory will be deleted when the power is turned off.

E34

Image 34
Contents Illustration with optional lens attachment This instruction book is made from 100% recycled paperSafety Precautions Varning Table of Contents Characters and symbols used in this instruction book MemoAccessories and attachments FeaturesIntroduction Line and patterns may appear distorted when recorded Phenomena unique to CCDPart names and their functions Front and bottomRear Mode E10Ventilation hole E11 This lamp lights when the power of the main unit is onUsed to connect the lens cable Mounting the lens Remoter terminal Metal 10-pin, female Explanation of terminalsE12 E13 Basic system For the power supply, always use the AA-P700 AC adapterBefore recording E14MO disk drive Model name E15AC adapter AdapterE16 InstallScrews E17 Female Lens remote controlMounting the lens Camera head Male Thread section Mount clamp ring LensE18 Connecting the powerClamp filter Attached power supply cable AC adapterE19 Connecting a monitorMonitor terminal Scsi Connecting an MO drive unitE20 Do not set the ID of the MO drive side to other thanE21 Connecting a printerDip switches Scsi Set the ID of the printer side to other thanChanging the camera mounting bracket position Mounting the cameraMounting method E22Fall prevention Fall prevention wire chain 6mm Camera headE23 Set to OFF E24Minal on the rear of the main unit Set to onLens settings Menu settingsVGA mode settings VGA mode and lens settings are made from the menu screenE26 Time and date settingsTime Adjust screen Play menu screenE27 OK display screenSet using the main unit dip switches Monitor settings Monitor adjustmentTurn the main unit power on Adjust the video monitor E28E29 Focus adjustmentPress the Menu button to return to the normal screen REC Menu screen Menu item Set value White balance adjustmentE30 White Balance screenAuto white in operation E31Auto white operation completed E32 White shading adjustmentREC Menu screen E33 E34 Basic operationsRecording images to the main unit memory Freeze displayPlaying back images from the memory Returning to the REC modePress the Mode button to enter the Play mode E35Saving images from the memory to an MO disk E36Use a printer with an Scsi input terminal Set to either the Freeze or Play modeOutputting images from the memory to a printer E37E38 Clearing images from the memoryVideo Memory Clear E39 Memory clearedRecording a PC monitor Various recording methodsE40 Outputting negative images System Setting screenE41 E42 Timing chart Sxga modeSynchronizing flash and Freeze High speed shutter onlyAbout ALC and EEI operations E43Menu screen flow Menu screen settingsE44 Freeze screen E45Exposure screen Process screenE46 Setting procedureREC normal menu screen REC normal menu screen Menu item Set valueREC quick menu screen About the submenu screens of the normal REC menuPlay menu screen E47Exposure screen E48E49 E50 White Balance screen E51Shading Mode OFFE52 Level GProcess 1/3 screen Freeze screenE53 Gamma @ADJUST set when changing the gamma curveE54 Used to set whether the gamma curve to determineFlare R Process 2/3 screenE55 Flare BMatrix E56Color Standard valueSystem Setting screen E57E58 Send Prioryty Menu screen of the Play modeE59 Video ME.MORYMenu item REC mode quick menu screenE60 TorSensitivity can be changed when the sensitivity mode Sensitivity can be changed using the Level Submenu itemE61 Resetting Resetting settingsMenu Reset screen SET button E62E63 Press the Menu once more to return to the normal screenCompatible systems Connecting to a PCCamera remote control software E64E65 Printer Flash Freeze switchAC adapter Analog RGB, WEN, Hs, Vs, RS-232C Others SpecificationsE66 E67 External dimensions unit mmInch screw SL96172