JVC TK-C676 Attach the Ceiling Mount to the Ceiling Flush Mount Bracket, Attach the ceiling panel

Page 43

Anchor bolt mount holes

 

Lock

Ceiling flush mount

screw

 

bracket attached to the

 

ceiling

 

Ceiling mount

4.P. 16, “Connection Cables”

5.Attaching a safety wire to the ceiling mount.Connect cables to the Ceiling Mount.

Attach a safety wire to the ceiling mount and to the ceiling slab or channel to prevent the unit from dropping. First attach the safety wire to the ceiling mount by passing the wire through the safety wire hole.

P. 18, step 1. “Attaching a safety wire”.

6.Attach the Ceiling Mount to the Ceiling Flush Mount Bracket.

Attach the Ceiling Mount to the Ceiling Flush Mount Bracket, tak- ing care not to catch the connection cables.

Please use the four screws provided (M4 x 12 mm). If the screws that have been removed in step 2. above are used, the camera may not be installed properly and may fall.

Attach so that the lock screw of the Ceiling Mount is positioned be- low the anchor bolt mount hole of the Ceiling Flush Mount Bracket.

Hook

MEMO

7. Attach the camera to the Ceiling Mount.

P. 18, “Attaching the Camera”

Ceiling panel

8. Attach the ceiling panel.

Attach the ceiling panel, provided with the Ceiling Flush Mount Brack- et, by attaching the two hooks one by one.

Both the ceiling flush mount bracket and the drop prevention attachment should be insulated from the ceiling structure.

If the ceiling structure is made of a metallic material, an improper insulation with the camera may produce noise in the video.

43

Image 43 Contents
LWT0200-001A-H TK-C655 TK-C676Important Safeguards Contents Instructions Ceiling mount FeaturesProvided Accessories 4P Alarm cable 6P Alarm cable Screws M 4 x 12 mmInstall the unit on a strong and stable surface Safety PrecautionsPower the unit with the rated power voltage Precautions for Correct Operation  Note on consumable parts  Note on auto focusing Preset positions Camera setups with which auto focusing may be diffi- cultCeiling Mount Controls, Connectors and IndicatorsConnector Male Camera Connector Female$ Machine ID Switch Setting SwitchesCable connections P Switch settings PObserve the following points when connecting compo Multi-Drop Communication SystemMemo Point-to-Point Communication System Switch 7 Invalid Set to OFF Switch 8 onTerminal side of the Ceiling Mount For example connection with an RM-P2580 Four wires must be connectedTwo wires must be connected Duplex Setting switches Switch SettingsExample Camera ID check procedureMachine ID Bers on the RM-P2580Remove the cover from the Ceiling Mount Cable ConnectionsMake a 90 mm diameter hole in the ceiling Connect the cablesAttach the cover Attaching the Camera Attaching a safety wireAttach the drop prevention wire Attaching the Ceiling MountTighten the lock screw Ensure that the lock screw is looseFit the camera Rotate the cameraPress the SET button Setup ProcedureSetting the camera menus from an RM-P2580 Press and hold the Menu button for 3 secondsNormal screen Menu Screen FlowMenu screen TK-C676 only Function & Setting Initial ValueCamera FUNCTION1 Screen This screen sets up the functions of the camera itselfCamera FUNCTION2 Screen Function & Setting1min Camera TITLE/ALARM Screen Alarm OUT1 Alarm Input PolarityAlarm Alarm OutputCamera ALC screen Camera Video Adjustment ScreenMode Sense UPMotion ColourArea Edit Colour ModeAlarm Display Home Motion Detect ScreenAuto PAN/PATROL/TRACE Screen Average Peak Iris ModePosition Function SET Screen Position TitleFactory Settings screen Private Mask Setup Repeat steps 5 and 6 for each title character Camera Title SetupTitle from the character area Press the Tele buttonPress the FAR button Area Title SetupDisplay the Setup menu on the camera Move the cursor to Area Title Edit and press the SET buttonTITLE/ALARM menu Alarm Title SetupRepeat steps 5 to 7 for each alarm title TITLE/ALARM screen is displayedArea Edit screen Home Motion Detect SetupMove the cursor to Area Edit and press the SET button Home Motion Detect menuSet the auto pan mode and speed Auto PAN SetupAdjust the viewing angle of the start position Auto Patrol Setup Auto Trace SET screen is displayed Auto Trace SetupMove the cursor to Auto Trace SET and press the SET button Set the patrol start positionPosition Function SET screen Position Title SetupSetup Repeat steps 5 to 7 for each title characterDisplay the Camera FUNCTION2 screen Auto Return SetupDisplay the Setup menu on the camera. P.20, steps 1 to Set the return status using Auto Return functionClamp the Ceiling Flush Mount Bracket Attaching a Ceiling Flush Mount Bracket Optional WB-S575Ceiling plate Connection Cables Attach the Ceiling Mount to the Ceiling Flush Mount BracketAttach the camera to the Ceiling Mount Attach the ceiling panelCheck the release labels thoroughly before removal Removing a Ceiling Flush Mount Bracket Optional WB-S575Remove the ceiling panel Remove the cameraTurned on TroubleshootingSymptom Cause Information Remedy Power cannot beGeneral SpecificationsCamera Pan/Tilt MechanismWB-S575 Ceiling flush mount bracket + Ceiling panel External dimensions Unit mmDimensions in combination with the WB-S575 Ceiling mount holeTK-C655/TK-C676 Dome Type Camera