JVC TK-C676 manual Controls, Connectors and Indicators, Ceiling Mount

Page 8

Connections & Installation

Controls, Connectors and Indicators

Ceiling Mount

0

Cover

98 7 6

1

2

5

 

 

3 4

(Connector side)

9Pin(CN24)1 of alarm output terminal

8Pin 1 of CONTROL terminal (CN22)

7Pin 1 of ALARM I/O terminal (CN23)

6Pin 1 of alarm input terminal (CN26)

(Terminal Pin Layout)

1[VIDEO OUT] Coaxial Cable Connectors

Output connector of a composite video signal (1 V(p-p)) with an output impedance of 75 , to be connected to a switcher, etc.

2[AC ` 24V INPUT] Connector

Connect to a 24 V AC power supply.

3Cover Position Alignment Mark

When attaching the cover, use this mark to align its final position correctly.

4Locking Screw

Tighten this screw to fasten the camera clamping bracket

*.

5Safety Wire Hole

To prepare for possible dropping of the camera, pass the wire from the ceiling slab or channel through this hole.

6Alarm Input Terminals (CN26)

Input terminals for Alarm 2, Alarm 3 and Alarm 4.

Connect the provided cables to these terminals. P. 17

Pin No.

Signal Name

Color of Cable

1

Alarm input 2

Brown

2

GND

Red

3

Alarm input 3

Orange

4

GND

Yellow

5

Alarm input 4

Violet

6

GND

Gray

 

 

 

7[ALARM I/O] Input/Output Terminals (CN23)

Terminals for Alarm input 1 and Alarm output 1. P. 17

Pin No.

Signal Name

1Alarm output 1 (N.OPEN)

2Alarm output 1 (COM)

3Alarm output 1 (N.CLOSE)

4Alarm input 1

5

GND

8[CONTROL] Terminals (CN22)

Connect to a RM-P2580 remote control unit.

Pin No.

Signal Name

Mark

1

TX +

A

 

 

2

TX –

B

 

 

3

RX +

C

 

 

4

RX –

D

 

 

9Alarm Output Terminals (CN24)

Output terminals for Alarm 2 and Alarm 3.

Connect the provided cables to these terminals. P. 17

Pin No.

Signal Name

Color of Cable

1

Alarm output 2 +

Red

2

Alarm output 2 –

White

3

Alarm output 3 +

Orange

4

Alarm output 3 –

Gray

 

 

 

8

Image 8 Contents
TK-C655 TK-C676 LWT0200-001A-HImportant Safeguards Contents Features Provided Accessories4P Alarm cable 6P Alarm cable Screws M 4 x 12 mm Instructions Ceiling mountPower the unit with the rated power voltage Safety PrecautionsInstall the unit on a strong and stable surface Precautions for Correct Operation  Note on auto focusing  Preset positionsCamera setups with which auto focusing may be diffi- cult  Note on consumable partsControls, Connectors and Indicators Ceiling MountCamera Connector Female $ Machine ID SwitchSetting Switches Connector MaleSwitch settings P Observe the following points when connecting compoMulti-Drop Communication System Cable connections PMemo Terminal side of the Ceiling Mount Switch 7 Invalid Set to OFF Switch 8 onPoint-to-Point Communication System Four wires must be connected Two wires must be connectedDuplex For example connection with an RM-P2580Switch Settings  Setting switchesCamera ID check procedure Machine IDBers on the RM-P2580 ExampleCable Connections Make a 90 mm diameter hole in the ceilingConnect the cables Remove the cover from the Ceiling MountAttach the cover Attaching a safety wire Attach the drop prevention wireAttaching the Ceiling Mount Attaching the CameraEnsure that the lock screw is loose Fit the cameraRotate the camera Tighten the lock screwSetup Procedure Setting the camera menus from an RM-P2580Press and hold the Menu button for 3 seconds Press the SET buttonMenu screen Menu Screen FlowNormal screen Function & Setting Initial Value Camera FUNCTION1 ScreenThis screen sets up the functions of the camera itself TK-C676 only1min Function & SettingCamera FUNCTION2 Screen Camera TITLE/ALARM Screen Alarm Input Polarity AlarmAlarm Output Alarm OUT1Camera Video Adjustment Screen Camera ALC screenSense UP MotionColour ModeColour Mode Alarm DisplayHome Motion Detect Screen Area EditAuto PAN/PATROL/TRACE Screen Iris Mode Position Function SET ScreenPosition Title Average PeakFactory Settings screen Private Mask Setup Camera Title Setup Title from the character areaPress the Tele button Repeat steps 5 and 6 for each title characterArea Title Setup Display the Setup menu on the cameraMove the cursor to Area Title Edit and press the SET button Press the FAR buttonAlarm Title Setup Repeat steps 5 to 7 for each alarm titleTITLE/ALARM screen is displayed TITLE/ALARM menuHome Motion Detect Setup Move the cursor to Area Edit and press the SET buttonHome Motion Detect menu Area Edit screenAdjust the viewing angle of the start position Auto PAN SetupSet the auto pan mode and speed Auto Patrol Setup Auto Trace Setup Move the cursor to Auto Trace SET and press the SET buttonSet the patrol start position Auto Trace SET screen is displayedPosition Title Setup SetupRepeat steps 5 to 7 for each title character Position Function SET screenAuto Return Setup Display the Setup menu on the camera. P.20, steps 1 toSet the return status using Auto Return function Display the Camera FUNCTION2 screenCeiling plate Attaching a Ceiling Flush Mount Bracket Optional WB-S575Clamp the Ceiling Flush Mount Bracket Attach the Ceiling Mount to the Ceiling Flush Mount Bracket Attach the camera to the Ceiling MountAttach the ceiling panel Connection CablesRemoving a Ceiling Flush Mount Bracket Optional WB-S575 Remove the ceiling panelRemove the camera Check the release labels thoroughly before removalTroubleshooting Symptom Cause Information RemedyPower cannot be Turned onSpecifications CameraPan/Tilt Mechanism GeneralExternal dimensions Unit mm Dimensions in combination with the WB-S575Ceiling mount hole WB-S575 Ceiling flush mount bracket + Ceiling panelTK-C655/TK-C676 Dome Type Camera