JVC Troubles with Error Code Outputs, Error Code Error Details GY-DV500 Operation Remedy

Page 46

14. OTHERS

14-1 Troubleshooting (Cont'd)

In the case of troubles occurring during operation of the GY-DV500, it performs a self-test to identify the cause and displays the result in the form of an error code. The error code consists of the "main code" which indicates its contents and the "sub-code" which indicates the details. Depending on the status of the GY-DV500 at this time, indications may also appear on the LCD display, the WARNING indicator may activate and the alarm tone may be generated.

In the viewfinder, the "VTR WARNING (DEW)" indication appears when condensation is detected, and the "VTR WARNING (STOP)", "VTR WARNING (HARD)" or "VTR WARNING (REW)" indication appears depending on the contents of the error code when some of the other error codes are displayed.

WARNING indicator

TALLY lamp

For servicing

See the service manual page 1-22 “1.16 WARNING CODES”.

14. OTHERS

14-1 Troubleshooting (Cont'd)

TROUBLES WITH ERROR CODE OUTPUTS

Error Code

Error Details

GY-DV500 Operation

Remedy

 

 

 

 

3200

Tape loading impossible.

Operation stops. All operations

Switch the power OFF and then

 

 

are rejected.

switch it back ON. However, the tape

 

 

 

may be damaged depending on the

3300

Tape unloading impossible.

Operation stops. All operations

situation. Please consult the person

 

 

are rejected.

 

 

in charge of professional video

 

 

 

 

 

 

equipment at your nearest JVC-

4000

Irregular cassette intake

Operation stops. All operations

authorized service agent.

 

operation.

are rejected.

 

 

 

 

 

 

4100

Irregular eject operation.

Operation stops. All operations

 

VTR WARNING (HARD)

VTR WARNING (DEW)

FILTER

ALARM

MONITOR

NG POWER

TALLY lamp

EARPHONE

ALARM

tone

 

 

are rejected.

 

 

 

 

 

4200

Cassette housing abnormality.

Operation stops. All operations

 

 

 

are rejected.

 

 

 

 

 

5605

Tape is cut.

Operation stops. All operations

Open the cassette cover by using the

 

 

are rejected.

EJECT switch and then switch the

 

 

 

power ON again.

 

 

 

 

5606 to 5607

Tape is slack.

Operation stops. All operations

Switch the power OFF and then

 

 

are rejected.

switch it back ON. However, the tape

 

 

 

may be damaged depending on the

 

 

 

Auto-OFF indicator:

Lights depending on the error code. When this indicator lights, the GY-DV500 will automatically stop operation or eject the cassette. The GY-DV500 does not accept any operation.

Dew condensation indicator

AUTO OFF DEW

Main code

Sub-code

5702

Tape end sensor error.

Operation stops. All operations

situation. Please consult the person

 

 

are rejected.

 

 

in charge of professional video

 

 

 

5802

Tape beginning sensor error.

Operation stops. All operations

equipment at your nearest JVC-

authorized service agent.

 

 

are rejected.

 

 

 

 

 

 

 

7001

Drum rotation stopped.

Operation stops. All operations

Switch the power OFF and then

 

 

are rejected.

switch it back ON. However, the tape

 

 

 

may be damaged depending on the

7101

Capstan rotation stopped.

Operation stops. All operations

situation. Please consult the person

 

 

are rejected.

 

 

in charge of professional video

 

 

 

7202 to 7203

Supply reel rotation error.

Operation stops. All operations

equipment at your nearest JVC-

authorized service agent.

 

 

are rejected.

 

 

 

WARNING indicator

Alarm Tone

Display

 

GY-DV500 Operation

 

 

 

 

Red. blinking

Continuous

"Error code"

• Automatically ejects the cassette. It can be inserted again.

 

 

 

 

 

 

"Error code"

• Automatically stops operation or ejects the cassette.

 

 

plus

(Auto OFF) * The GY-DV500 does not accept any operation.

 

 

"AUTO OFF"

 

 

 

 

 

 

Red, blinking

Intermittent

"DEW "

• Dew condensation inside the unit.

 

 

 

The GY-DV500 does not accept any operation until the DEW indicator

 

 

 

disappears from the display.

 

 

 

 

 

* In the Auto OFF status, it is impossible to operate the GY-

 

DV500. This condition can be cancelled by switching the

The GY-DV500 is a microcomputer-controlled piece of

POWER switch OFF and then switching it ON again. If the

equipment, which may malfunction due to external noise

same problem occurs again after the power is turned ON,

or interference. In this case, set the POWER switch to OFF,

there may be something wrong with the GY-DV500. Please

remove the lithium backup battery, and then set the

consult the person in charge of professional video equipment

POWER switch to ON again after a few minutes.

at your nearest JVC-authorized service agent.

 

 

7302 to 7303

Take up reel rotation error.

Operation stops. All operations

 

 

are rejected.

 

 

 

7305

Irregular tape winding when

Operation stops. All operations

 

unloading.

are rejected.

8990

Image 46
Contents Precautions for Use of Head Cleaning Tape Precautions when writing S.S.F. dataFor Customer Use Varning InformationRemarque VaroitusMain Features 10. S.S.F. Super Scene Finder FunctionPrecautions for Proper Use Main Unit ConfigurationIntroduction Characteristic CCD Phenomena Routine and Periodical MaintenanceBattery Pack to be Used CondensationFront Section Front Section Cont’dCamera Setting Section Time Code Generator setting switches Audio Setting SectionVCR Setup Block Right Side Section ContdVCR Display Section Left Side Section Top SectionRear Section Rear Section ContdCounter Display Contents S14 x 7.3B12 Lens optional1.5-Inch Viewfinder optional VF-P115BIndications in Viewfinder Contd  Warning LED Indicators Inside the ViewfinderIndications in Viewfinder  Viewfinder Screen Display Alarm Message Display Indication Indication ContentsBasic System  Safety Zone Setting the Screen Display  Auto White Balance DisplayAttaching the Microphone optional Attaching the Zoom Lens optionalAttaching the Microphone provided Attaching the Viewfinder How to Install the Lithium Battery Inserting and Replacing Backup Lithium BatteriesLithium battery CR2032  How to Remove Lithium BatteriesBattery Pack Operation Power SupplyBattery Pack Operation Contd Attaching a Flat Shape Type Battery PackPrecautions for the Battery Pack Remaining Battery Power DisplayAttaching and Detaching an Anton-Bauer Battery Pack Using an Anton-Bauer Battery PackCassette Loading and Unloading Turning the Power onPreparations Loading the CassettePower on Setting the Date and TimeCamera Settings FilterBack Focus Adjustment Viewfinder AdjustmentExternal Monitor Adjustment Switch Settings of the VCR Section White Balance AdjustmentWhite Balance Adjustment Audio Input Signal Selection Recording Level AdjustmentMonitoring Audio during Recording Shooting OperationBasic Recording Operation Recording from the Save mode VCR Save ModeIf Unit is Left in Record-Pause Standby Mode About the Quick REC ModePlayback Procedure Playback ModeOperation Fast-Forward, Rewind Presetting and Recording of Time CodeTime Code Operation Displaying Time CodeTime Code Presetting Procedure for E-ver Time Code Presetting Procedure for U-verPresetting Users BIT Data SettingExplanation of the S.S.F. Function  Mark ModeReproducing Time Codes CUECUE Mode How to Use the S.S.F. FunctionResetting S.S.F. Data Mark ModeWriting S.S.F. Data to Tape Using External ComponentsConnecting a Video Component with DV Connector Outputting S.S.F. DataVCR Setup Menu Setup MenuConnecting a PC VCR Setup Menu ConfigurationDisplaying and Setting VCR Setup Menus VCR Setup Menu ContdVCR Setup Menu Contents Camera Menu Screen Flow Setting Factory Group Value ContentsCamera Menu Screen Flow Time CodeHow to Select from the Camera Menu VF Display ScreenOperation Screen Process ScreenFile Manage Screen Skin Color Adjust ScreenAdvanced Process Screen Storage OperationResetting of Camera Menu Setting Values Setup ScreenReset Operation Adjustment of Lens Iris Features of the Camera SectionIris Brightness Adjustment Zebra Pattern Display During Manual AdjustmentShooting the Screen Image on a Computer Monitor Gain Sensitivity AdjustmentGain Switching  OutlineSwitch Functions Switch Setup According to Illumination and SubjectHow to Use Skin Detail Full Auto Shooting FAS FunctionAlarm Indications How to Use Skin Detail Cont’dTroubleshooting  Using the Skin Detail FunctionTroubleshooting Contd Alarm Indications ContdDew condensation indicator Troubles with Error Code OutputsError Code Error Details GY-DV500 Operation Remedy Alarm Tone Display GY-DV500 OperationSymptoms Remedy Troubles Without Error Code OutputsHour Meter Display Specifications Contd SpecificationsExternal Dimensions unit mm