JVC GY-DV500 Basic Recording Operation Contd, VCR Save Mode, Recording from the Save mode

Page 27

7. SHOOTING OPERATION

7-1 Basic Recording Operation (Cont'd)

7. SHOOTING OPERATION

7-2 VCR Save Mode

8. 9. 10.

VTR trigger button

8. TALLY lamp

OFF ZEBRA

8. Press the VTR trigger button on the GY-DV500 or lens to start recording.

Once recording has started, the BACK TALLY lamp on the rear section of the unit and the tally lamp on the viewfinder light red, and the REC indication in the viewfinder lights green.

Note:

* The lightning conditions of the BACK TALLY lamp on

the rear section of the unit can be changed by setting

the VCR Setup Menu item No. 082 BACK TALLY MODE.

* The lamp in the viewfinder and on the front section will

blink from when the button is pressed and until recording

actually starts. See page 68.

9. To stop recording, press the VTR trigger button again. The

TALLY lamp and REC indicator lamp go out and the unit

enters the record-pause mode.

When the VTR trigger button is pressed, the unit enters the

record-pause mode after rewinding the tape for about 2

 

 

L

CAM

ON

KNEE

B

VTR

 

A

STBY

H

BARS

 

AUTO

PRST

 

M

 

OFF

WHT.BAL

switch

SAVE

GAIN

OUTPUT

VTR

 

NG POWER

ONOFF

When a recordable videocassette is loaded, the GY-DV500 enters the record-pause mode. However, the record-pause operation condition differs depending on the setting of the VTR switch.

VTR switch setting

STBY : The GY-DV500 enters the record-pause mode, and the drum is rotating at this time. (Standby mode) The "STBY" indicator appears in the VCR operation status display in the viewfinder (in Status 1 mode).

In this condition, recording starts immediately when

the VTR trigger button is pressed.

SAVE : The GY-DV500 enters the record-pause mode but the drum is not rotating. (Save mode).

The tape is protected.

The "SAVE" indicator appears in the viewfinder (in Status 1 mode).

The OPERATE indicator lights orange. The display backlight turns off.

Note:

ON

SKIN

AUTO

AREA

WHITE

 

ACCU

FOCUS

VTR AUDIO TAKE

LEVEL CH-1

11.

seconds (back-spacing).

10.To restart recording:

Press the VTR trigger button on the GY-DV500 or lens.

11.Ending recording:

Enter record-pause mode and perform the following

Viewfinder

ACCU - FOCUS

G

F

When the VCR Setup Menu item No. 396 SSF MODE is set to the CUE MODE or MARK mode, the VCR save mode is not entered.

Recording from the Save mode

 

 

 

E

B

 

L

MA

NO EN

AT

Y

C

FKO

SR

BT

M

SR

FOTU

P

SE

H

AB

A

WHT.BAL

S

 

 

 

VA

 

OUTPUT

 

VTR

GAIN

 

 

 

 

 

NG POWER

ONOFF

12.

8. 9. 10.

VTR trigger button

operations as required.

 When it is required to unload the videocassette:

• Slide the EJECT switch.

 When it is required to put the unit in save mode:

• Set the VTR switch to SAVE.

Drum rotation stops and the GY-DV500 enters the tape

protection/power-saving mode.

12.When shooting is completely finished, eject the cassette

and set the POWER switch to “OFF”.

When the unit is not going to be used for a long period,

VCR operation status display

STBY

or

SAVE

 

 

 

I

 

 

 

SD

 

 

 

B

 

CH1

- - - - + - -

 

F 5 . 6

CH2

- - - - + - -

M 09 9

STBY

 

< 6 0

1 2 . 4V

(Status 1 mode)

In the save mode, pressing the VTR trigger button will start recording.

However, in this case, it takes several seconds before the GY-DV500 starts recording.

Pressing the VTR trigger button again interrupts the recording and the GY-DV500 enters the save mode again.

detach the battery pack.

7-3 If Unit is Left in Record-Pause (Standby) Mode

About the QUICK REC Mode

When the GY-DV500 has remained in record-pause (standby) mode for about 30 minutes, the unit enters the save mode, in which the drum rotation is stopped automatically and the tape

• The time until the unit enters the save mode after it is

placed in record-pause mode can be set to 3 minutes or

 

REC

8.

BATT ALARM

 

8. TALLY lamp

Note:

If the VTR trigger button is pressed immediately after the videocassette is inserted, the mode becomes the QUICK REC mode that enables quick start of recording.

However, when shooting starts in the middle of the tape, a blank space appears as the new scene will not be linked smoothly with the previous image.

Also, the time code does not continue. (Some overlap may also occur.)

tension is released. (Save mode)

To start recording from the save mode, press the VTR trigger button; the drum starts to rotate and recording starts in about 3 seconds.

To return to the record-pause mode from the save mode, press the VTR trigger button TWICE; the drum starts to rotate.

30 minutes with the VCR Setup Menu item No. 307 LONG

PAUSE TIME.

When used in a cold environment, the setting will be 3

minutes regardless of the setting on the VCR Setup

Menu.

See page 69.

The unit enters stop mode at tape-end automatically, and if kept longer than 3 or 30 minutes in this mode, SAVE mode is maintained. See “Menu No. 307: LONG PAUSE TIME” on page 69.

If the VTR trigger button is pushed very quickly and repeatedly, or the POWER switch is moved immediately after being pressed, the viewfinder REC indicator lamp may blink and the GY-DV500 may not enter the record mode. To remedy this condition set the POWER switch to OFF and wait for 5 seconds or more before turning the power on again.

A neat transition to the next recorded scene cannot be guaranteed if you end a recording by turning the POWER switch or DC power supply OFF, or by removing the battery pack.

Before recording a scene that is particularly important, perform test shooting to ensure that normal recording is possible.

The power consumption can be reduced by setting the LIGHT switch on the display and TALLY lamp to OFF.

The microphone may pick up the sound of the lens’ iris if the iris is changed abruptly or the iris is manually moved abruptly during recording. If you find the noise annoying, please purchase an optional microphone in order to move the microphone away from the lens or ensure that the iris is not changed abruptly during shooting.

 

For servicing

 

51

The QUICK REC mode of this unit is different from conventional models such as (GY-X1, GY-X2, and GY-

 

X2B). It is not a fully automatic mode operation. In this case it is a function that shortens the time to the

 

 

initiation of the start of the recording.

 

 

 

 

 

 

 

52

Image 27
Contents Precautions when writing S.S.F. data Precautions for Use of Head Cleaning TapeFor Customer Use Varoitus InformationRemarque Varning10. S.S.F. Super Scene Finder Function Main FeaturesMain Unit Configuration Precautions for Proper UseIntroduction Condensation Routine and Periodical MaintenanceBattery Pack to be Used Characteristic CCD PhenomenaFront Section Cont’d Front SectionCamera Setting Section Right Side Section Contd Audio Setting SectionVCR Setup Block Time Code Generator setting switchesVCR Display Section Top Section Left Side SectionRear Section Contd Rear SectionCounter Display Contents VF-P115B Lens optional1.5-Inch Viewfinder optional S14 x 7.3B12 Viewfinder Screen Display  Warning LED Indicators Inside the ViewfinderIndications in Viewfinder Indications in Viewfinder ContdIndication Indication Contents  Alarm Message Display Auto White Balance Display  Safety Zone Setting the Screen Display Basic SystemAttaching the Viewfinder Attaching the Zoom Lens optionalAttaching the Microphone provided Attaching the Microphone optional How to Remove Lithium Batteries Inserting and Replacing Backup Lithium BatteriesLithium battery CR2032  How to Install the Lithium BatteryAttaching a Flat Shape Type Battery Pack Power SupplyBattery Pack Operation Contd Battery Pack OperationUsing an Anton-Bauer Battery Pack Remaining Battery Power DisplayAttaching and Detaching an Anton-Bauer Battery Pack Precautions for the Battery PackLoading the Cassette Turning the Power onPreparations Cassette Loading and UnloadingFilter Setting the Date and TimeCamera Settings Power onViewfinder Adjustment Back Focus AdjustmentExternal Monitor Adjustment White Balance Adjustment Switch Settings of the VCR SectionWhite Balance Adjustment Recording Level Adjustment Audio Input Signal SelectionShooting Operation Monitoring Audio during RecordingBasic Recording Operation About the Quick REC Mode VCR Save ModeIf Unit is Left in Record-Pause Standby Mode Recording from the Save modePlayback Mode Playback ProcedureOperation Displaying Time Code Presetting and Recording of Time CodeTime Code Operation Fast-Forward, RewindSetting Time Code Presetting Procedure for U-verPresetting Users BIT Data Time Code Presetting Procedure for E-verCUE  Mark ModeReproducing Time Codes Explanation of the S.S.F. FunctionMark Mode How to Use the S.S.F. FunctionResetting S.S.F. Data CUE ModeOutputting S.S.F. Data Using External ComponentsConnecting a Video Component with DV Connector Writing S.S.F. Data to TapeVCR Setup Menu Configuration Setup MenuConnecting a PC VCR Setup MenuVCR Setup Menu Contd Displaying and Setting VCR Setup MenusVCR Setup Menu Contents Time Code Setting Factory Group Value ContentsCamera Menu Screen Flow Camera Menu Screen FlowVF Display Screen How to Select from the Camera MenuProcess Screen Operation ScreenStorage Operation Skin Color Adjust ScreenAdvanced Process Screen File Manage ScreenSetup Screen Resetting of Camera Menu Setting ValuesReset Operation Zebra Pattern Display During Manual Adjustment Features of the Camera SectionIris Brightness Adjustment Adjustment of Lens Iris Outline Gain Sensitivity AdjustmentGain Switching Shooting the Screen Image on a Computer MonitorFull Auto Shooting FAS Function Switch Setup According to Illumination and SubjectHow to Use Skin Detail Switch Functions Using the Skin Detail Function How to Use Skin Detail Cont’dTroubleshooting Alarm IndicationsAlarm Indications Contd Troubleshooting ContdAlarm Tone Display GY-DV500 Operation Troubles with Error Code OutputsError Code Error Details GY-DV500 Operation Remedy Dew condensation indicatorTroubles Without Error Code Outputs Symptoms RemedyHour Meter Display Specifications Specifications ContdExternal Dimensions unit mm