JVC GY-DV500 instruction manual Connecting a PC, VCR Setup Menu Configuration, Connections

Page 34

11. USING EXTERNAL COMPONENTS

11-2 Connecting a PC

12. SETUP MENU

12-1 VCR Setup Menu

PUSH

DV CAMCORDER

GY-DV500

The setup menus for the VCR section can be set while observing the menu in the viewfinder and on the unit's counter display. The set contents are stored in the memory and retained even after the power is switched OFF.

VCR SETUP MENU CONFIGURATION

The VCR Setup Menu is a two-layer construction.

The VCR Setup Menu consists of seven group menus divided according to functions. When a Group menu is selected, the menu's Item menu opens. Each Item menu contains one or several items, and the various items can be set individually as required.

DV connector

Y/C OUT MONITOR OUT

LINE OUT

CH-1 CH-2

 

 

VTR

REMOTE

SYNC IN

TEST OUT

MIC IN

LENS

VTR REMOTE connector

TTLRS-232C converter cable

RS-232C

PC

RS-232C

VCR Setup Menu

Group Name

000 SERVO/SYSTEM

Item Menu Contents

Selection of remote control to control the unit Selection of BACK TALLY lamp lighting pattern

MONITOR

AUDIO OUT

OUT

 

connector

 

(Optional VC-P893)

AUDIO IN

VIDEO IN

Non-linear editing controller

100VIDEO (U-ver. only)

200AUDIO

300 SYSTEM

Selection of video input

Selection of low cut for audio input signals

Selection of sampling frequency for audio input signals Selection of front section audio volume control

Selection of long pause/still duration

Selection of battery type

DV connector

Connections

Connect the GY-DV500's VTR REMOTE connector to the RS-232C connector on the PC or the non-linear editing controller using the TTL RS-232C converter cable.

400TIME CODE (U-ver. only)

500ON SCREEN HM HOUR METER

Selection of S.S.F. (Super Scene Finder) mode

Selection of time code framing mode

Selection of counter display method (Time code/Date/Time)

Display of hour meter (accumulated running time of head drum)

Or connect the GY-DV500’s DV connector and the DV connector of the non-linear editing controller using a DV cable. For compatible non-linear editing controller, consult with your JVC dealer.

Settings

To remote control the PC or non-linear editing controller by means of RS-232C, set the VCR Setup Menu item No. 050 REMOTE SELECT to "RS232C". See page 68.

To remote control the GY-DV500’s VCR using the DV connector’s IEEE1394 option, set the VCR Setup Menu item No. 050 REMOTE SELECT to “IEEE1394”. See page 68.

Note:

When a cable is connected to the VTR REMOTE connector, the VTR Setup Menu is not displayed in the viewfinder. Make settings on the VTR Setup Menu while the cable is not connected.

When a cable is connected to the VTR REMOTE connector, the VCR operation mode will not be displayed correctly on the Status1 screen in the viewfinder.

The S.S.F. data stored in the unit's memory is output from the VTR REMOTE connector.

U-ver.

 

 

Item Menu

Viewfinder display

 

Group Menu

 

(example: AUDIO)

 

 

 

MENU button

0 0 0

: SERVO / SYSTEM

2 4 4 : LOW CUT

OF F

1 0 0

: V I DEO

SELECT button

 

2 0 0

: AUD I O

2 4 5 : SAMP L E

RATE

Normal screen

3 0 0

: SYSTEM

 

4 8 K

4 0 0

: T I ME CODE

2 4 6 : FRONT VOLUME

MENU button

5 0 0

: ON SCREEN

MENU button

ENAB L E

HM

: HOUR METER

 

 

 

DATA SET button

 

 

Counter display

 

 

 

 

E-ver.

 

 

 

 

Viewfinder display

 

Group Menu

 

 

 

 

 

 

Item Menu

 

 

 

 

 

 

(example: AUDIO)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 0 0

: SERVO / SYSTEM

 

 

 

 

 

2 4 4

: LOW CUT

 

MENU button

1 0 0

: V I DEO

SELECT button

 

OF F

 

2 0 0

: AUD I O

2 4 5

: SAMP L E RATE

 

 

 

 

 

 

 

 

 

 

 

Normal screen

 

 

 

 

 

3 0 0

: SYSTEM

 

 

 

 

 

 

4 8 K

 

 

 

 

 

4 0 0

: T I ME CODE

 

 

 

 

 

2 4 6

: FRONT VOLUME

 

MENU button

5 0 0

: ON SCREEN

MENU button

 

ENAB L E

 

HM

: HOUR METER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA SET button

Counter display

6566

Image 34
Contents Precautions for Use of Head Cleaning Tape Precautions when writing S.S.F. dataFor Customer Use Varning InformationRemarque VaroitusMain Features 10. S.S.F. Super Scene Finder FunctionPrecautions for Proper Use Main Unit ConfigurationIntroduction Characteristic CCD Phenomena Routine and Periodical MaintenanceBattery Pack to be Used CondensationFront Section Front Section Cont’dCamera Setting Section Time Code Generator setting switches Audio Setting SectionVCR Setup Block Right Side Section ContdVCR Display Section Left Side Section Top SectionRear Section Rear Section ContdCounter Display Contents S14 x 7.3B12 Lens optional1.5-Inch Viewfinder optional VF-P115BIndications in Viewfinder Contd  Warning LED Indicators Inside the ViewfinderIndications in Viewfinder  Viewfinder Screen Display Alarm Message Display Indication Indication ContentsBasic System  Safety Zone Setting the Screen Display  Auto White Balance DisplayAttaching the Microphone optional Attaching the Zoom Lens optionalAttaching the Microphone provided Attaching the Viewfinder How to Install the Lithium Battery Inserting and Replacing Backup Lithium BatteriesLithium battery CR2032  How to Remove Lithium BatteriesBattery Pack Operation Power SupplyBattery Pack Operation Contd Attaching a Flat Shape Type Battery PackPrecautions for the Battery Pack Remaining Battery Power DisplayAttaching and Detaching an Anton-Bauer Battery Pack Using an Anton-Bauer Battery PackCassette Loading and Unloading Turning the Power onPreparations Loading the CassettePower on Setting the Date and TimeCamera Settings FilterBack Focus Adjustment Viewfinder AdjustmentExternal Monitor Adjustment Switch Settings of the VCR Section White Balance AdjustmentWhite Balance Adjustment Audio Input Signal Selection Recording Level AdjustmentMonitoring Audio during Recording Shooting OperationBasic Recording Operation Recording from the Save mode VCR Save ModeIf Unit is Left in Record-Pause Standby Mode About the Quick REC ModePlayback Procedure Playback ModeOperation Fast-Forward, Rewind Presetting and Recording of Time CodeTime Code Operation Displaying Time CodeTime Code Presetting Procedure for E-ver Time Code Presetting Procedure for U-verPresetting Users BIT Data SettingExplanation of the S.S.F. Function  Mark ModeReproducing Time Codes CUECUE Mode How to Use the S.S.F. FunctionResetting S.S.F. Data Mark ModeWriting S.S.F. Data to Tape Using External ComponentsConnecting a Video Component with DV Connector Outputting S.S.F. DataVCR Setup Menu Setup MenuConnecting a PC VCR Setup Menu ConfigurationDisplaying and Setting VCR Setup Menus VCR Setup Menu ContdVCR Setup Menu Contents Camera Menu Screen Flow Setting Factory Group Value ContentsCamera Menu Screen Flow Time CodeHow to Select from the Camera Menu VF Display ScreenOperation Screen Process ScreenFile Manage Screen Skin Color Adjust ScreenAdvanced Process Screen Storage OperationResetting of Camera Menu Setting Values Setup ScreenReset Operation Adjustment of Lens Iris Features of the Camera SectionIris Brightness Adjustment Zebra Pattern Display During Manual AdjustmentShooting the Screen Image on a Computer Monitor Gain Sensitivity AdjustmentGain Switching  OutlineSwitch Functions Switch Setup According to Illumination and SubjectHow to Use Skin Detail Full Auto Shooting FAS FunctionAlarm Indications How to Use Skin Detail Cont’dTroubleshooting  Using the Skin Detail FunctionTroubleshooting Contd Alarm Indications ContdDew condensation indicator Troubles with Error Code OutputsError Code Error Details GY-DV500 Operation Remedy Alarm Tone Display GY-DV500 OperationSymptoms Remedy Troubles Without Error Code OutputsHour Meter Display Specifications Contd SpecificationsExternal Dimensions unit mm