JVC GY-DV500 Indications in Viewfinder Contd,  Warning LED Indicators Inside the Viewfinder

Page 14

2. CONTROLS, INDICATORS AND CONNECTORS

2-9 Indications in Viewfinder

2. CONTROLS, INDICATORS AND CONNECTORS

2-9 Indications in Viewfinder (Cont'd)

WARNING LED INDICATORS INSIDE THE VIEWFINDER

ACCU - FOCUS

G

F

1

 

ACCU - FOCUS

2

G

 

3

F

1

2

3

SCENE

F I L E

A

 

WH I TE

BA L

A

 

F I L TER

 

3

. 2 K

SHUT TER

1

/ 1 0 0 0

GA I N

 

6 d B

BATT

REC

ALARM

The viewfinder has two LED indicators below the screen. These LEDs light or blink to indicate the present status of the camera or the VCR.

[BATT] battery lamp

This lights red when the battery voltage becomes too low for

operating the camera.

REC/ALARM lamp

I

SD

B

7

4

57 SDI

6

 

 

B

 

CH1

- - - - + - -

 

F 5 . 6

CH2

- - - - + - -

M 09 9

STBY

 

< 6 0

1 2 . 4V

9 B 0 8 A

4

5

6 C

I R I S

L EVE L

NORMA L

I R I S DETECT

NORMA L

FUL L

AUTO

OF F

REC

T I ME

< 6 0

BATTREC/ALARM

LampLamp

This lights or blinks green under the following circumstances.

Steady green : During recording.

Blinks green : • While the GY-DV500 switches from record- pause to recording.

Immediately before the tape is running out or when it has run out.

When an error occurs in the GY-DV500.

 

Status 0

 

Status 1

Status 2

Status 0

 

 

 

 

 

 

 

 

 

Display Position

Display

Function

 

 

 

 

 

 

1

ACCU-FOCUS

Blinks during the ACCU-FOCUS operation.

 

VIEWFINDER SCREEN DISPLAY

The following indications are displayed on the viewfinder screen. (However, this information is not displayed while the VCR section is playing back a tape.)

Status screens (screens for use in checking the current camera settings)

Alarm message display

Safety zone display

Setting screen (screen for use in the camera and VCR setup)

Auto white balance display

Shutter speed display

 

SKIN AREA

Blinks while the skin tone detail color area is displayed.

 

S

Displayed when the SHUTTER or V-SCAN is ON.

 

FAS

Displayed when the Full Auto Shooting is ON.

 

ALC

Displayed when the ALC alone is ON.

 

 

 

2

G

Displayed in other modes than 0 dB, LOLUX and ALC.

 

L

Displayed during LOLUX operation.

3

F

Displayed when FAW alone is ON.

4

I

Displayed when IRIS BACK LIGHT or IRIS SPOT LIGHT is selected.

5

SD

Displayed while the Skin Detail function is in operation.

6

B

Displayed when BLACK STRETCH or BLACK COMPRESSION is selected.

Status Screens

STATUS button

FILTER

1

3200k

 

 

ALARM

2

5600k

 

 

 

3

5600k+ND

 

 

SHUTTER

STATUS

 

MONITOR

MENU

 

 

 

 

 

FULL AUTO BLACK

 

 

 

 

OUTPUT

L

VTR

GAIN

WHT.BA

 

 

 

 

NG

POWER

 

 

 

ON

OFF

Press the STATUS button during normal screen display to show one of the status screens in the viewfinder. One of the three status screens will be displayed every time the button is pressed.

 

OPERATE/WARNING

 

LIGHT

RESET

ON

 

OFF

MONITOR

COUNTER

SELECT

 

CTL

 

TC

 

UB

CH-1 AUDIO CH-2

LEVEL

7

Event display See the table below.

7Event display

Event is displayed in the viewfinder for only about 2 seconds when any of the following switches is operated.

Switch

 

Event Display Contents

ZEBRA

ZEBRA

ON, OFF

BLACK

BLACK

STRETCH, NORMAL, COMPRESS

GAIN

GAIN

–3 dB, 0 dB, 6 dB, 9 dB, 12 dB, 18 dB, ALC

 

 

 

WHT. BAL

WHITE BAL

A, B, PRESET, FAW

FULL AUTO

FULL AUTO

ON, OFF

AUTO IRIS

IRIS

BACK.L, NORMAL, SPOT.L

LOLUX

LOLUX

ON, OFF

FILTER knob

FILTER

3.2K, 5.6K, 5.6K+ND

 

 

 

VTR

VTR

STBY, SAVE

AUTO KNEE

AUTO KNEE

ON, OFF

ACCU - FOCUS

G

F

I

SD

B

ACCU - FOCUS

 

 

 

G

 

 

 

F

 

 

 

I

 

 

 

SD

 

 

 

B

 

CH1 -

- - - + - -

 

F 5 . 6

CH2 -

- - - + - -

M 09 9

STBY

 

< 6 0

1 2 . 4V

SCENE

F I L E

A

 

WH I TE

BA L

A

 

F I L TER

3 .

2 K

SHUT TER

1 /

1 0 0 0

GA I N

 

6 d B

I R I S

L EVE L

NORMA L

I R I S DETECT

NORMA L

FUL L

AUTO

OF F

REC T I ME

< 6

0

Status 0

Status 1

Status 2

25

26

27

Image 14
Contents For Customer Use Precautions when writing S.S.F. dataPrecautions for Use of Head Cleaning Tape Varning InformationRemarque VaroitusMain Features 10. S.S.F. Super Scene Finder FunctionIntroduction Main Unit ConfigurationPrecautions for Proper Use Characteristic CCD Phenomena Routine and Periodical MaintenanceBattery Pack to be Used CondensationFront Section Front Section Cont’dCamera Setting Section Time Code Generator setting switches Audio Setting SectionVCR Setup Block Right Side Section ContdVCR Display Section Left Side Section Top SectionRear Section Rear Section ContdCounter Display Contents S14 x 7.3B12 Lens optional1.5-Inch Viewfinder optional VF-P115BIndications in Viewfinder Contd  Warning LED Indicators Inside the ViewfinderIndications in Viewfinder  Viewfinder Screen Display Alarm Message Display Indication Indication ContentsBasic System  Safety Zone Setting the Screen Display  Auto White Balance DisplayAttaching the Microphone optional Attaching the Zoom Lens optionalAttaching the Microphone provided Attaching the Viewfinder How to Install the Lithium Battery Inserting and Replacing Backup Lithium BatteriesLithium battery CR2032  How to Remove Lithium BatteriesBattery Pack Operation Power SupplyBattery Pack Operation Contd Attaching a Flat Shape Type Battery PackPrecautions for the Battery Pack Remaining Battery Power DisplayAttaching and Detaching an Anton-Bauer Battery Pack Using an Anton-Bauer Battery PackCassette Loading and Unloading Turning the Power onPreparations Loading the CassettePower on Setting the Date and TimeCamera Settings FilterExternal Monitor Adjustment Viewfinder AdjustmentBack Focus Adjustment White Balance Adjustment White Balance AdjustmentSwitch Settings of the VCR Section Audio Input Signal Selection Recording Level AdjustmentBasic Recording Operation Shooting OperationMonitoring Audio during Recording Recording from the Save mode VCR Save ModeIf Unit is Left in Record-Pause Standby Mode About the Quick REC ModeOperation Playback ModePlayback Procedure Fast-Forward, Rewind Presetting and Recording of Time CodeTime Code Operation Displaying Time CodeTime Code Presetting Procedure for E-ver Time Code Presetting Procedure for U-verPresetting Users BIT Data SettingExplanation of the S.S.F. Function  Mark ModeReproducing Time Codes CUECUE Mode How to Use the S.S.F. FunctionResetting S.S.F. Data Mark ModeWriting S.S.F. Data to Tape Using External ComponentsConnecting a Video Component with DV Connector Outputting S.S.F. DataVCR Setup Menu Setup MenuConnecting a PC VCR Setup Menu ConfigurationVCR Setup Menu Contents VCR Setup Menu ContdDisplaying and Setting VCR Setup Menus Camera Menu Screen Flow Setting Factory Group Value ContentsCamera Menu Screen Flow Time CodeHow to Select from the Camera Menu VF Display ScreenOperation Screen Process ScreenFile Manage Screen Skin Color Adjust ScreenAdvanced Process Screen Storage OperationReset Operation Setup ScreenResetting of Camera Menu Setting Values Adjustment of Lens Iris Features of the Camera SectionIris Brightness Adjustment Zebra Pattern Display During Manual AdjustmentShooting the Screen Image on a Computer Monitor Gain Sensitivity AdjustmentGain Switching  OutlineSwitch Functions Switch Setup According to Illumination and SubjectHow to Use Skin Detail Full Auto Shooting FAS FunctionAlarm Indications How to Use Skin Detail Cont’dTroubleshooting  Using the Skin Detail FunctionTroubleshooting Contd Alarm Indications ContdDew condensation indicator Troubles with Error Code OutputsError Code Error Details GY-DV500 Operation Remedy Alarm Tone Display GY-DV500 OperationHour Meter Display Troubles Without Error Code OutputsSymptoms Remedy External Dimensions unit mm SpecificationsSpecifications Contd