9. TIME CODE OPERATION
9. TIME CODE OPERATION
TIME CODE PRESETTING PROCEDURE (for U-ver.)
| 2. HOLD button |
|
| 4. | SHIFT button | 1. Display the time code on the counter display. | |
|
|
| Set the COUNTER switch to "TC". | ||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| • Time code up to 23 hrs. 59 min. 59 sec. 29 frames can be |
|
|
|
|
|
|
| preset. |
AUDIO |
| TC GENERATOR | 2. Place the time code generator in preset mode. | ||||
| LEVEL | REGEN | REC | ||||
|
|
| MANUAL | ||||
|
|
| AUTO | PRESET | FREE | Press the HOLD button. | |
|
| AUDIO SELECT |
|
|
| ||
|
| AUDIO INPUT | CONTINUE | MENU | • The "HOLD" indicator lights on the display to indicate | ||
|
| FRONT | |||||
|
|
| |||||
|
|
| REAR |
|
|
| the preset mode. The first digit of the counter display |
| LITHIUM BATT. |
| GROUP | ITEM | SELECT | DATA SET | |
|
|
| HOLD | SHIFT | ADVANCE | PRESET | blinks. |
|
|
|
|
|
| 6. | 3. Set the value of the blinking digit. |
|
| 3. ADVANCE |
| Press the ADVANCE button. | |||
|
|
| PRESET | • The value of the blinking digit changes. | |||
|
|
| button |
| |||
|
|
|
| button | 4. Change the blinking digit. | ||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
|
|
|
|
| HOLD |
| Press the SHIFT button. |
|
|
|
|
|
|
| • The blinking digit changes. |
|
| H | M | S | F |
|
PRESETTING USER'S BIT DATA
RESET button
OPERATE/WARNING
LIGHT
RESET | CH 1 |
|
| OVER | AUTO OFF DEW | ON | |||
| 40 30 20 | 10 | 0 dB | SERVO RF | L i | ||||
| CH 2 |
|
| OVER | OFF | ||||
| 32k | 48k |
| PB | NDF | HOLD |
| ||
MONITOR | AUD LOCK | SP |
|
|
|
|
|
| COUNTER |
SELECT | MENU |
| H | M |
| S |
| F | |
| REMAIN |
| REV FWD | E | BATT | F | CTL | ||
|
|
|
|
|
|
| TC | ||
|
| H | M |
|
|
|
|
| UB |
•Pressing the RESET button in the preset mode resets the time code or user's bit data to 00 00 00 00.
•If you press the HOLD button by mistake, press the HOLD button once more to return to the previous display.
Display user's bit data on the counter display and perform the same procedure as the time code presetting procedure.
•The user's bit can be specified using numerals or alphabetic letters from 0 to F for each digit.
Note:
Do not specify F in the user’s bit data.
Specification of F results in a special setting and reading of user’s bit data during playback may become impossible. If all user’s bit digits are set to F, the data cannot be read.
HOLD
H M S F
HOLD
H M S F
HOLD
H M S F
5. Set the desired value for all digits. Repeat steps 3. and 4. for each digit.
6. Preset the set data in the memory. Press the PRESET button.
•The set data is saved as the time code generator value. Following the above operation, the "HOLD" indicator disappears from the display, the counter stops blinking and the time code is preset.
•If the REC/FREE switch is set to FREE, the time code starts to run.
If you preset a wrong time code, perform steps 2. 3. 4. 5. and
6.again.
The
*However, approximately
TIME CODE PRESETTING PROCEDURE (for E-ver.)
| 2. HOLD button |
|
| 4. | SHIFT button | 1. Display the time code on the counter display. | |
|
|
| Set the COUNTER switch to "TC". | ||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| • Time code up to 23 hrs. 59 min. 59 sec. 24 frames can be |
|
|
|
|
|
|
| preset. |
AUDIO |
| TC GENERATOR | 2. Place the time code generator in preset mode. | ||||
| LEVEL | REGEN |
| REC | |||
|
|
| MANUAL |
| |||
|
|
| AUTO | PRESET | FREE | Press the HOLD button. | |
|
| AUDIO SELECT |
|
|
| ||
|
| AUDIO INPUT | CONTINUE | MENU | • The "HOLD" indicator lights on the display to indicate | ||
|
| FRONT | |||||
|
|
| |||||
|
|
| REAR |
|
|
| the preset mode. The first digit of the counter display |
| LITHIUM BATT. |
| GROUP | ITEM | SELECT | DATA SET | |
|
|
| HOLD | SHIFT | ADVANCE PRESET | blinks. | |
|
|
|
|
|
| 6. | 3. Set the value of the blinking digit. |
|
| 3. ADVANCE |
| Press the ADVANCE button. | |||
|
|
| PRESET | • The value of the blinking digit changes. | |||
|
|
| button |
| |||
|
|
|
| button | 4. Change the blinking digit. | ||
|
|
|
|
|
| ||
|
|
|
| HOLD |
| ||
|
|
|
|
|
|
| Press the SHIFT button. |
|
| H | M | S | F |
| • The blinking digit changes. |
|
|
|
| HOLD |
| 5. Set the desired value for all digits. | |
|
|
|
|
|
|
| Repeat steps 3. and 4. for each digit. |
|
| H | M | S | F |
|
|
|
| PRESET/REGEN switch | Setting | ||||
|
|
|
|
|
| ||
| TC GENERATOR | Set the VCR Setup Menu item No. 516 DISPLAY SELECT to | |||||
LEVEL |
|
|
| ||||
|
| AUTO | PRESET | FREE | |||
|
| MANUAL | REGEN |
| REC | “TC”. | |
| AUDIO SELECT |
|
|
| |||
| AUDIO INPUT | CONTINUE | MENU | ☞ See page 69. | |||
| |||||||
|
| FRONT |
|
|
|
|
|
|
| REAR |
|
|
| Set the counter display to show time codes or user's bit data. | |
LITHIUM BATT. |
| GROUP | ITEM | SELECT | DATA SET | ||
|
| HOLD | SHIFT | ADVANCE PRESET | Set the PRESET/REGEN switch to REGEN. | ||
|
|
|
|
|
| ||
|
|
|
|
|
| • | The time code run mode becomes unrelated to the REC/ |
|
|
|
|
|
|
| FREE switch settings. |
|
|
|
|
|
| • | The time code framing mode automatically becomes the |
|
|
|
|
|
|
| mode (drop frame or non drop frame) already recorded on |
|
|
|
|
|
|
| the tape. |
HOLD
H M S F
HOLD
H M S F
6. Preset the set data in the memory. Press the PRESET button.
•The set data is saved as the time code generator value. Following the above operation, the "HOLD" indicator disappears from the display, the counter stops blinking and the time code is preset.
•If the REC/FREE switch is set to FREE, the time code starts to run.
If you preset a wrong time code, perform steps 2. 3. 4. 5. and
6.again.
5758