5. The VS gen-lock mode has its own menu for hori-

zontal phase adjustments. When the cable length

of the video output or the gen-lock input is

changed, the horizontal phase must be re-adjust-

ed.

6. The line-lock mode has its own menu for line-lock

vertical phase adjustment. If the camera installa-

tion is relocated, check the vertical phase adjust-

ment again since the AC line phase may be differ-

ent.

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

ALC

SHUTTER

---

 

AGC

 

ON

 

SENS

UP

OFF

 

SYNC

 

INT

 

MOTION DET

OFF

LENS

DRIVE

DC

 

END

SET UP ENABLE

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

ALC

SHUTTER

---

 

AGC

 

ON

 

SENS

UP

OFF

 

SYNC

 

EXT

(VS)

MOTION DET

OFF

LENS

DRIVE

DC

 

END

SET UP ENABLE

6-1. VS Gen-lock Mode (EXT(VS))

1.Move the cursor to the SYNC parameter and select INT.

2.Connect the coaxial cable for the composite sync or composite B/W video signal to the gen-lock input connector.

3.Confirm that the parameter INT changed to EXT (VS) on the menu.

Caution: The gen-lock input signal should meet with EIA RS-170 specifications and should not contain jitter, such as a VCR playback signal , as it could disturb synchronization.

4.After confirming the cursor is on EXT (VS), press

. The phase adjustment menu appears on the monitor.

** SYNC **

 

H PHASE

 

........I

 

-

+

RET END

5.Move the cursor to H PHASE. The cursor starts blinking.

6.Supply the video output signal of the camera to be adjusted and the reference gen-lock input signal to a dual-trace oscilloscope.

-26-

Image 28
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Features PrefacePrecautions Clean the CCD faceplate with careDo not attempt to disassemble the camera Handle the camera with careMajor Operating Controls and Their Functions WV-BP554Auto Iris Lens Connector Flange-back Adjusting RingGen-lock Termination Switch Hi-Z, G/L 75Ω Power indicatorVideo Output Connector Video OUT Power Cord SocketAlarm Output Terminal Alarm OUT/GND AC/DC Compatible Input Terminal DC 12V IN/AC 24VDC Power Supply ConnectionsWV-BP550 120V AC 60Hz WV-BP554 12V DC/24V ACAC Power Supply Recommended wire gauge sizes for 24V AC lineRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the bottom Installation of CameraMounting from the top SET UP Camera Setup MenuMotion Detector Setup Operation All Reset OperationEditing the CAM SET UP Menu Opening the Setup MenuImportant Notice Editing the Special menu Setting Procedures Camera Identification Camera ID SettingTo edit the Camera ID To enter a blank space in the Camera IDLight Control Setting ALC/ELC To return to the CAM SET UP menuTo erase all characters in the editing area To determine the display position of the Camera IDALC Mode with SUPER-D on Super Dynamic Function SUPER-DALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFF Electronic Sensitivity Enhancement Sens UPSynchronization Setting Sync Important NoticesVS Gen-lock Mode Extvs EntLine-lock Sync Mode LL Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveAperture Gain Setting AP Gain Pedestal Level Setting PedestalSpecial Menu Special Camera Picture Upside Down PositioningPrevention of Blooming and Smear Specifications Standard Accessories Optional AccessoriesVideo Imaging Systems Company Regional Offices