Panasonic WV-BP550 manual Lens Drive Signal Selection Lens

Page 31

6.To raise detection sensitivity, press to return to the MOTION DETECT menu.

7.To obtain the optimum detection level, move the “I” cursor to adjust the level.

8.Repeat the procedures above to obtain a satisfac- tory setting.

9.Move the cursor to RET and press to return to the CAM SET UP menu.

Notes:

Masking or adjusting the detection level is needed to prevent malfunction under the following condi- tions:

When shooting an object under flickering fluores- cent light or shooting in ELC.

When leaves or curtains etc. are swayed by the wind.

When the object is lighted by lighting equipment that constantly turns on and off.

It takes about 0.2 seconds for the alarm signal to reach the alarm terminal of the VCR after the cam- era detects the object.

Because the alarm signal is multiplexed on the video signal, it may be mistakenly interpreted by other video equipment as a time code signal.

Therefore, when camera is not used in a Panasonic Intelligent CCTV System select OFF to prevent the above from occurring.

8.Lens Drive Signal Selection (LENS

DRIVE)

This item is used to select the type of auto iris lens drive signal to be supplied to the lens from the auto iris lens connector.

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

ALC

SHUTTER

---

 

AGC

 

ON

 

SENS

UP

OFF

 

SYNC

 

INT

 

MOTION DET

OFF

LENS

DRIVE

DC

 

END

SET UP ENABLE

1.Move the cursor to the LENS DRIVE parameter.

2.Select DC if you are using the auto iris lens that requires a DC drive signal.

Select VIDEO if you are using the auto iris lens that requires a video drive signal.

-29-

Image 31
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Preface FeaturesHandle the camera with care PrecautionsClean the CCD faceplate with care Do not attempt to disassemble the cameraWV-BP554 Major Operating Controls and Their FunctionsPower indicator Auto Iris Lens ConnectorFlange-back Adjusting Ring Gen-lock Termination Switch Hi-Z, G/L 75ΩAC/DC Compatible Input Terminal DC 12V IN/AC 24V Video Output Connector Video OUTPower Cord Socket Alarm Output Terminal Alarm OUT/GNDWV-BP554 12V DC/24V AC DC Power SupplyConnections WV-BP550 120V AC 60HzRecommended wire gauge sizes for 24V AC line AC Power SupplyRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the bottom Installation of CameraMounting from the top Camera Setup Menu SET UPMotion Detector All Reset Operation Setup OperationEditing the CAM SET UP Menu Opening the Setup MenuImportant Notice Editing the Special menu To enter a blank space in the Camera ID Setting ProceduresCamera Identification Camera ID Setting To edit the Camera IDTo determine the display position of the Camera ID Light Control Setting ALC/ELCTo return to the CAM SET UP menu To erase all characters in the editing areaSuper Dynamic Function SUPER-D ALC Mode with SUPER-D onALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Electronic Sensitivity Enhancement Sens UP Gain Control Setting AGC ON/OFFImportant Notices Synchronization Setting SyncEnt VS Gen-lock Mode ExtvsLine-lock Sync Mode LL Motion Detector Setting Motion DET Drive Lens Drive Signal Selection LensCamera Picture Upside Down Positioning Aperture Gain Setting AP GainPedestal Level Setting Pedestal Special Menu SpecialPrevention of Blooming and Smear Specifications Optional Accessories Standard AccessoriesRegional Offices Video Imaging Systems Company