Panasonic WV-BP550 manual Synchronization Setting Sync, Important Notices

Page 27

When ON is selected for SUPER-D, the SENS UP SELECT function for the WV-CU254 or WV-CU300 system controller does not work.

Use the buttons on the side of the camera for setup.

While the SENS UP function is selected, noise or spots may appear in the picture when the sensitivi- ty of the camera is increased. This is a normal phenomenon.

6.Synchronization Setting (SYNC)

You can select internal sync mode (INT) or line-lock mode (LL). Additionally, this model accepts VS signal (B/W composite video or composite sync signal). The VD2 signal (multiplexed vertical drive signal) with the composite video output signal from external equipment such as a Matrix Switcher is also acceptable.

Whenever the VD2 signal is supplied to this camera, the camera automatically switches to the VD2 sync mode.

1.Move the cursor to the SYNC parameter and select line-lock(LL) or internal(INT).

2.Press .

If LL is selected, the SYNC menu appears. (If INT is selected, the synchronization mode is automati- cally set to internal sync pulse, and the menu is not displayed.)

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

ALC

SHUTTER

---

 

AGC

 

ON

 

SENS

UP

OFF

 

SYNC

 

INT

 

MOTION DET

OFF

LENS

DRIVE

DC

 

END

SET UP ENABLE

Important Notices:

1.The priority for the sync modes is as follows.

1.Multiplexed Vertical Drive (VD2) (Highest pri- ority)

2.Line-lock (LL)

3.B/W Composite Video or Composite Sync Signal (VS)

4.Internal Sync (INT) (Lowest priority)

2.When the internal sync mode is to be used, select INT. No gen-lock input signal should be supplied to the Gen-lock Input Connector on the rear panel.

3.Whenever the multiplexed vertical drive pulse (VD2) is supplied to the camera from an external equipment such as a Matrix Switcher, the camera sync mode is automatically switched to the VD2 mode.

4.When the VS gen-lock mode is to be used select INT from this menu and supply the gen-lock input signal to the Gen-lock Input Connector on the rear panel.

-25-

Image 27
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Preface FeaturesHandle the camera with care PrecautionsClean the CCD faceplate with care Do not attempt to disassemble the cameraWV-BP554 Major Operating Controls and Their FunctionsPower indicator Auto Iris Lens ConnectorFlange-back Adjusting Ring Gen-lock Termination Switch Hi-Z, G/L 75ΩAC/DC Compatible Input Terminal DC 12V IN/AC 24V Video Output Connector Video OUTPower Cord Socket Alarm Output Terminal Alarm OUT/GNDWV-BP554 12V DC/24V AC DC Power SupplyConnections WV-BP550 120V AC 60HzRecommended wire gauge sizes for 24V AC line AC Power SupplyRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Installation of Camera Mounting from the bottomMounting from the top Camera Setup Menu SET UPMotion Detector All Reset Operation Setup OperationOpening the Setup Menu Editing the CAM SET UP MenuImportant Notice Editing the Special menu To enter a blank space in the Camera ID Setting ProceduresCamera Identification Camera ID Setting To edit the Camera IDTo determine the display position of the Camera ID Light Control Setting ALC/ELCTo return to the CAM SET UP menu To erase all characters in the editing areaSuper Dynamic Function SUPER-D ALC Mode with SUPER-D onALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Electronic Sensitivity Enhancement Sens UP Gain Control Setting AGC ON/OFFImportant Notices Synchronization Setting SyncEnt VS Gen-lock Mode ExtvsLine-lock Sync Mode LL Motion Detector Setting Motion DET Drive Lens Drive Signal Selection LensCamera Picture Upside Down Positioning Aperture Gain Setting AP GainPedestal Level Setting Pedestal Special Menu SpecialPrevention of Blooming and Smear Specifications Optional Accessories Standard AccessoriesRegional Offices Video Imaging Systems Company