Panasonic WV-BP550 manual Video Output Connector Video OUT, Power Cord Socket

Page 8

!3 Video Output Connector (VIDEO OUT)

This connector is used to connect with the VIDEO IN connector of the monitor.

!4 Power Cord Socket

This socket is used to connect the power cord (supplied as a standard accessory).

!5 Alarm Output Terminal (ALARM OUT/GND)

This terminal is used to connect to the ALARM INPUT connector (terminal) of an external equip- ment. When this camera detects motion, the alarm output signal is supplied to the connected external equipment.

(Open collector output: 16V DC 100mA max.)

!6 AC/DC Compatible Input Terminal (DC 12V IN/AC 24V IN)

This terminal is for connecting the 12 V DC or 24 V AC power supply cord.

Cautions:

1.Connect to 12V DC (10.5V-16V) or 24V AC (19.5V-28V) class 2 power supply only. Make sure to connect the grounding lead to the GND terminal when the power is supplied from a 24V AC power source.

2.To prevent fire or electric shock hazard, use a UL listed wire VW-1, style 1007 cable for the Input Terminal.

-6-

Image 8
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Features PrefacePrecautions Clean the CCD faceplate with careDo not attempt to disassemble the camera Handle the camera with careMajor Operating Controls and Their Functions WV-BP554Auto Iris Lens Connector Flange-back Adjusting RingGen-lock Termination Switch Hi-Z, G/L 75Ω Power indicatorVideo Output Connector Video OUT Power Cord SocketAlarm Output Terminal Alarm OUT/GND AC/DC Compatible Input Terminal DC 12V IN/AC 24VDC Power Supply ConnectionsWV-BP550 120V AC 60Hz WV-BP554 12V DC/24V ACAC Power Supply Recommended wire gauge sizes for 24V AC lineRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the top Installation of CameraMounting from the bottom SET UP Camera Setup MenuMotion Detector Setup Operation All Reset OperationImportant Notice Opening the Setup MenuEditing the CAM SET UP Menu Editing the Special menu Setting Procedures Camera Identification Camera ID SettingTo edit the Camera ID To enter a blank space in the Camera IDLight Control Setting ALC/ELC To return to the CAM SET UP menuTo erase all characters in the editing area To determine the display position of the Camera IDALC Mode with SUPER-D on Super Dynamic Function SUPER-DALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFF Electronic Sensitivity Enhancement Sens UPSynchronization Setting Sync Important NoticesVS Gen-lock Mode Extvs EntLine-lock Sync Mode LL Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveAperture Gain Setting AP Gain Pedestal Level Setting PedestalSpecial Menu Special Camera Picture Upside Down PositioningPrevention of Blooming and Smear Specifications Standard Accessories Optional AccessoriesVideo Imaging Systems Company Regional Offices