3.4Power connection

The camera can accept power from both the DC12V power input and the Ethernet input at the same time. You can remove either one of the power sources without interrupting camera operation.

3.4.1DC power connection

5 mm

(0.2 in)

22AWG

12 VDC

Figure 3.2 DC power connection

Connect power from a 12 VDC class 2 power supply as follows:

1.Use AWG22 wire; cut back 5 mm (0.2 in) of insulation.

2.Remove the 2-pole connector from the camera cable tree.

3.Loosen the screws and insert the wires.

4.Tighten the screws and reconnect the 2-pole connector to the power connector of the camera cable tree.

Bosch Security Systems

Installation Manual

AM18-Q0616 v1 2012.02

Image 15
Contents IP Camera 200 Series Page Table of Contents Technical Data MaintenanceSafety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceMore information UL certificationBosch notices DisclaimerCopyrights Introduction FeaturesCD ROM Unpacking Disassembly InstallationMicroSDHC card RJ45 Ethernet PoE Network and power connectorDC power connection Power connectionFunction Wire Color I/O connectorAudio connectors Audio connectorsMounting the camera MountingCamera set-up Camera positioning IP Camera 200 Series Installation en Focal length and focus Resetting the camera System requirements Browser connectionPassword protection in camera Establishing the connectionProtected network Malfunction Possible causes Solution TroubleshootingResolving problems Customer serviceMaintenance RepairsTransfer and disposal Specifications Technical DataIP Camera 200 SeriesTechnical Data en Accessories Page Bosch Security Systems