Axis Communications Q6044 user manual Triggers

Page 38

AXIS Q6044 PTZ Dome Network Camera

Events

For more information, see the online help .

Triggers

Available action rule triggers and conditions include:

Applications – Use installed applications to trigger the rule. See Applications on page 35.

Detectors

-Audio Detection – Trigger the rule when audio is detected. See Audio Detection on page 34.

-Live Stream Accessed – Trigger the rule when any stream is accessed and during edge storage playback. This can for example be used to send notifications.

-Motion Detection – Trigger the rule when motion is detected. See Motion Detection on page 33.

-Shock Detected – Trigger the rule when the Axis product detects it has been tilted or hit. See Shock Detection on page 33.

Hardware

-Fan – Trigger the rule if the fan is malfunctioning. This can for example be used to send maintenance notifications.

-Network – Trigger the rule if network connection is lost or restored. This can for example be used to start recording to the SD card.

-Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. This can for example be used to send maintenance notifications.

Input Signal

-Digital Input Port – Trigger the rule when an I/O port receives a signal from a connected device. See I/O Ports on page 54.

-Manual Trigger – Trigger the rule using the Manual Trigger button in the Live View page. See Controls on the Live View Page on page 10. This can for example be used to validate actions during product installation and configuration.

-Virtual Inputs – can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for example, be connected to buttons in the VMS user interface.

PTZ

-Autotracking – Trigger the rule when autotracking starts or stops. See Autotracking on page 29.

-Error – Trigger the rule if the PTZ functionality is not working correctly. This can for example be used to send maintenance notifications.

-Ready – Trigger the rule when the PTZ functionality is ready to be used. This can for example be used to steer the camera to a specific preset position when the product is started.

Storage

-Disruption – Trigger the rule if storage problems are detected, for example if the storage device is unavailable, removed, full, locked or if other read or write problems occur. This can for example be used to send maintenance notifications.

-Recording – Triggers the rule when the Axis product records to the storage device. The recording status trigger can be used to notify the operator, for example by flashing LED lights, if the product has started or stopped to record to the storage device. Note that, this trigger can be used only for edge storage recording status.

System

38

Image 38
Contents Axis Q6044 PTZ Dome Network Camera Liability About this DocumentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q6044 PTZ Dome Network CameraReset to Factory Default Settings Connectors Performance ConsiderationsFor technical specifications, see Connectors and ButtonsNetwork Connector Hardware OverviewPower Button LED IndicatorsMulti-connector SD Card SlotMidspan LED Indicators Green Steady when AC power input connectedAccess from the Internet Access the ProductAccess from a Browser Set the Root PasswordClick Use Https Live ViewControls on the Live View Manual Trigger Go to Setup EventsAxis Media Control viewer toolbar To show the manual trigger buttons in the Live ViewPTZ Controls Speaker button Click to turn the speakers on or offAxis Q6044 PTZ Dome Network Camera Axis Media Control AMC How to Stream H.264Media Streams Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccess Audio Streams Java applet supports simplex audio with G.711 encodingSet Up the Product Basic SetupPixel Counter Video and AudioVideo Stream ImageStream Profiles 264Image Appearance Camera SettingsExposure Settings White BalanceOverlay Image Image SettingsOverlay Go to Video & Audio Video Stream and select the Image tabGo to Events Action Rules Use Overlay Text in an Action RuleGo to Video & Audio Overlay Image Audio Modes Audio SettingsPrivacy Mask Audio Output Audio ClipsAudio Input Axis Q6044 PTZ Dome Network Camera Viewer Settings Configure the Live ViewDefault Viewer for Browsers Browser Viewer DescriptionOutput Buttons Go to Setup Live View ConfigUser Defined Links PTZ Pan Tilt Zoom Preset PositionsGo to PTZ Preset Positions GatekeeperExclude Areas ConfigurationAutotracking Max LimitsTo add a guard tour Guard TourTour Recording To add a recorded tourLimits Osdi ZonesAdvanced ControlsOperator Same as administrator but with lower priority Control QueueShock Detection Set Up Motion Detection WindowsDetectors Motion DetectionAudio Detection Applications Install ApplicationGo to Setup Applications Application LicensesAxis Q6044 PTZ Dome Network Camera Convert Event Types to Action Rules Set Up Action RulesEvents Go to Events Action Rules and click AddTriggers Recipient Types Add RecipientsActions Set Up Email Recipients Recipient Use with actionTo create a new schedule Set Up RecurrencesCreate Schedules Go to Events Schedules and click AddContinuous Recording RecordingsRecording List Go to Recordings ListClick Save to save and start the recording Languages Users System OptionsSecurity IP Address FilterGo to System Options Security Ieee IeeeCertificates Click Install certificate and upload the certificate To install a self-signed certificateGo to Setup System Options Security Certificates Date & TimeBasic TCP/IP Settings NetworkAxis Internet Dynamic DNS Service requires IPv4 Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service DNS ConfigurationLink-Local IPv4 Address NTP ConfigurationHost Name Configuration NAT traversal port mapping for IPv4QoS Quality of Service FTPUPnPTM UPnPTM can be disabled under System Options Network UPnPTMSmtp email RTP/H.264SD Card StorageBonjour Mount and Unmount SD CardPorts Ports & DevicesNetwork Share Port StatusSupport Overview MaintenanceSupport System OverviewScripting Reset to Factory Default SettingsPlain Config File UploadAxis Q6044 PTZ Dome Network Camera Function Pin Specifications Multi-Connector Cable sold separatelyCable provides the following connectors To max 40 V DC, open drain, 100 mAConnector Emergency Recovery Procedure TroubleshootingUpgrade the Firmware Check the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallySetup Video & Audio Camera Settings Problems with streaming H.264Video and image problems, general Key framesNo audio SettingsStorage and disk management problems Poor audio qualityTechnical Specifications Maintenance Function/group Specifications Network SecurityInstallation aid PowerConnectors Performance ConsiderationsAxis Q6044 PTZ Dome Network Camera M4.2