Axis Communications Q6044 Multi-Connector Cable sold separately, Function Pin Specifications

Page 58

AXIS Q6044 PTZ Dome Network Camera

Multi-Connector Cable (sold separately)

Multi-Connector Cable (sold separately)

When connecting external equipment to the Axis product, a multi-connector cable (available from Axis) is required in order to maintain the product’s IP rating. The multi-connector cable can be purchased from your Axis reseller.

Connect the multi-connector cable to the product’s multi-connector. To locate the multi-connector, see Hardware Overview on page

6 . The cable provides the following connectors:

Power connector - 3-pin terminal block used for power input. See image below. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a rated output power limited to 100 W or a rated output current limited to 5 A.

Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).

Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier . A stereo connector must be used for the audio out.

I/O terminal connector - Use with external devices in combination with, for example, tampering alarms, motion detection, event triggering, time lapse recording and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:

Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under System Options > Port & Devices > Port Status) if the alarm device is activated.

Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under System Options > Port & Devices > Port Status).

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1

 

 

 

 

 

 

DC output

2

Can be used to power auxiliary equipment.

3.3 V DC

 

 

Note: This pin can only be used as power out.

Max load = 250 mA

 

 

 

 

Configurable (Input

3–6

Digital input – Connect to pin 1 to activate, or leave

0 to max 40 V DC

or Output)

 

floating (unconnected) to deactivate.

 

 

 

 

 

Digital output – Connected to pin 1 when activated, floating (unconnected) when deactivated. If used with an inductive load, e.g. a relay, a diode must be connected

0 to max 40 V DC, open drain, 100 mA

58

Image 58
Contents Axis Q6044 PTZ Dome Network Camera Liability About this DocumentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q6044 PTZ Dome Network CameraReset to Factory Default Settings Connectors Performance ConsiderationsFor technical specifications, see Connectors and ButtonsNetwork Connector Hardware OverviewPower Button LED IndicatorsMulti-connector SD Card SlotMidspan LED Indicators Green Steady when AC power input connectedAccess from the Internet Access the ProductAccess from a Browser Set the Root PasswordControls on the Live View Live ViewClick Use Https Manual Trigger Go to Setup EventsAxis Media Control viewer toolbar To show the manual trigger buttons in the Live ViewPTZ Controls Speaker button Click to turn the speakers on or offAxis Q6044 PTZ Dome Network Camera Media Streams How to Stream H.264Axis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccess Audio Streams Java applet supports simplex audio with G.711 encodingSet Up the Product Basic SetupPixel Counter Video and AudioVideo Stream ImageStream Profiles 264Image Appearance Camera SettingsExposure Settings White BalanceOverlay Image Image SettingsOverlay Go to Video & Audio Video Stream and select the Image tabGo to Video & Audio Overlay Image Use Overlay Text in an Action RuleGo to Events Action Rules Privacy Mask Audio SettingsAudio Modes Audio Input Audio ClipsAudio Output Axis Q6044 PTZ Dome Network Camera Viewer Settings Configure the Live ViewDefault Viewer for Browsers Browser Viewer DescriptionUser Defined Links Go to Setup Live View ConfigOutput Buttons PTZ Pan Tilt Zoom Preset PositionsGo to PTZ Preset Positions GatekeeperExclude Areas ConfigurationAutotracking Max LimitsTo add a guard tour Guard TourTour Recording To add a recorded tourLimits Osdi ZonesAdvanced ControlsOperator Same as administrator but with lower priority Control QueueShock Detection Set Up Motion Detection WindowsDetectors Motion DetectionAudio Detection Applications Install ApplicationGo to Setup Applications Application LicensesAxis Q6044 PTZ Dome Network Camera Convert Event Types to Action Rules Set Up Action RulesEvents Go to Events Action Rules and click AddTriggers Actions Add RecipientsRecipient Types Set Up Email Recipients Recipient Use with actionTo create a new schedule Set Up RecurrencesCreate Schedules Go to Events Schedules and click AddContinuous Recording RecordingsRecording List Go to Recordings ListClick Save to save and start the recording Languages Users System OptionsSecurity IP Address FilterCertificates IeeeGo to System Options Security Ieee Click Install certificate and upload the certificate To install a self-signed certificateGo to Setup System Options Security Certificates Date & TimeBasic TCP/IP Settings NetworkAxis Internet Dynamic DNS Service requires IPv4 Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service DNS ConfigurationLink-Local IPv4 Address NTP ConfigurationHost Name Configuration NAT traversal port mapping for IPv4QoS Quality of Service FTPUPnPTM UPnPTM can be disabled under System Options Network UPnPTMSmtp email RTP/H.264SD Card StorageBonjour Mount and Unmount SD CardPorts Ports & DevicesNetwork Share Port StatusSupport Overview MaintenanceSupport System OverviewScripting Reset to Factory Default SettingsPlain Config File UploadAxis Q6044 PTZ Dome Network Camera Function Pin Specifications Multi-Connector Cable sold separatelyCable provides the following connectors To max 40 V DC, open drain, 100 mAConnector Emergency Recovery Procedure TroubleshootingUpgrade the Firmware Check the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallySetup Video & Audio Camera Settings Problems with streaming H.264Video and image problems, general Key framesNo audio SettingsStorage and disk management problems Poor audio qualityTechnical Specifications Maintenance Function/group Specifications Network SecurityInstallation aid PowerConnectors Performance ConsiderationsAxis Q6044 PTZ Dome Network Camera M4.2