Axis Communications Q6044 Recording List, Continuous Recording, Go to Recordings List

Page 42

AXIS Q6044 PTZ Dome Network Camera

Recordings

Recordings

The Axis product can be configured to record video continuously or according to an action rule:

To start a continuous recording, see page 42.

To set up action rules, see page 37.

To access recordings, see Recording List on page 42.

To configure camera controlled storage, see Storage on page 53.

Recording List

Recorded videos are listed on the Recordings > List page. The list shows each recording’s start date and time, duration and the event that triggered the recording.

To play or download a recording, follow these steps:

1.Go to Recordings > List.

2.Use the filter to narrow the list of recordings. Enter the desired filter criteria and click Filter. Some filters may take a long time to complete.

3.Select the recording.

4.Click Play to play the recording, or click Download to download the recording.

Multiple recordings can be downloaded at the same time. Select the recordings and click Download. The downloaded file is a zip file containing a minimum of three files, of which the Matroska (mkv) files are the actual recordings. The recordings are time-stamped with the date and time they were downloaded (that is, not the date the recordings were made).

Note

To play recordings in Windows Media Player, AXIS Matroska File Splitter must be installed. AXIS Matroska File Splitter can be downloaded from www.axis.com/techsup/software

For detailed recording and video information, select a recording and click Properties.

To remove a recording, select the recording and click Remove.

Continuous Recording

The Axis product can be configured to continuously save video to a storage device. For information about storage devices, see Storage on page 53. To prevent the disk from becoming full, it is recommended to configure the disk to automatically remove old recordings.

If a new stream profile is selected while a recording is ongoing, the recording will be stopped and saved in the recording list and a new recording with the new stream profile will start. All previous continuous recordings will remain in the recording list until they are removed manually or through automatic removal of old recordings.

To start a continuous recording, follow these steps:

1.Go to Recordings > Continuous.

2.Select Enabled.

3.Select the type of storage device from the Storage list.

4.Select a Stream profile to use for continuous recordings. To include audio in the recording, use AAC audio encoding and make sure that audio is enabled in the selected stream profile.

42

Image 42
Contents Axis Q6044 PTZ Dome Network Camera Liability About this DocumentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q6044 PTZ Dome Network CameraReset to Factory Default Settings Connectors Performance ConsiderationsFor technical specifications, see Connectors and ButtonsNetwork Connector Hardware OverviewPower Button LED IndicatorsMulti-connector SD Card SlotMidspan LED Indicators Green Steady when AC power input connectedAccess from the Internet Access the ProductAccess from a Browser Set the Root PasswordLive View Controls on the Live ViewClick Use Https Manual Trigger Go to Setup EventsAxis Media Control viewer toolbar To show the manual trigger buttons in the Live ViewPTZ Controls Speaker button Click to turn the speakers on or offAxis Q6044 PTZ Dome Network Camera How to Stream H.264 Media StreamsAxis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccess Audio Streams Java applet supports simplex audio with G.711 encodingSet Up the Product Basic SetupPixel Counter Video and AudioVideo Stream ImageStream Profiles 264Image Appearance Camera SettingsExposure Settings White BalanceOverlay Image Image SettingsOverlay Go to Video & Audio Video Stream and select the Image tabUse Overlay Text in an Action Rule Go to Video & Audio Overlay ImageGo to Events Action Rules Audio Settings Privacy MaskAudio Modes Audio Clips Audio InputAudio Output Axis Q6044 PTZ Dome Network Camera Viewer Settings Configure the Live ViewDefault Viewer for Browsers Browser Viewer DescriptionGo to Setup Live View Config User Defined LinksOutput Buttons PTZ Pan Tilt Zoom Preset PositionsGo to PTZ Preset Positions GatekeeperExclude Areas ConfigurationAutotracking Max LimitsTo add a guard tour Guard TourTour Recording To add a recorded tourLimits Osdi ZonesAdvanced ControlsOperator Same as administrator but with lower priority Control QueueShock Detection Set Up Motion Detection WindowsDetectors Motion DetectionAudio Detection Applications Install ApplicationGo to Setup Applications Application LicensesAxis Q6044 PTZ Dome Network Camera Convert Event Types to Action Rules Set Up Action RulesEvents Go to Events Action Rules and click AddTriggers Add Recipients ActionsRecipient Types Set Up Email Recipients Recipient Use with actionTo create a new schedule Set Up RecurrencesCreate Schedules Go to Events Schedules and click AddContinuous Recording RecordingsRecording List Go to Recordings ListClick Save to save and start the recording Languages Users System OptionsSecurity IP Address FilterIeee CertificatesGo to System Options Security Ieee Click Install certificate and upload the certificate To install a self-signed certificateGo to Setup System Options Security Certificates Date & TimeBasic TCP/IP Settings NetworkAxis Internet Dynamic DNS Service requires IPv4 Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service DNS ConfigurationLink-Local IPv4 Address NTP ConfigurationHost Name Configuration NAT traversal port mapping for IPv4QoS Quality of Service FTPUPnPTM UPnPTM can be disabled under System Options Network UPnPTMSmtp email RTP/H.264SD Card StorageBonjour Mount and Unmount SD CardPorts Ports & DevicesNetwork Share Port StatusSupport Overview MaintenanceSupport System OverviewScripting Reset to Factory Default SettingsPlain Config File UploadAxis Q6044 PTZ Dome Network Camera Function Pin Specifications Multi-Connector Cable sold separatelyCable provides the following connectors To max 40 V DC, open drain, 100 mAConnector Emergency Recovery Procedure TroubleshootingUpgrade the Firmware Check the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallySetup Video & Audio Camera Settings Problems with streaming H.264Video and image problems, general Key framesNo audio SettingsStorage and disk management problems Poor audio qualityTechnical Specifications Maintenance Function/group Specifications Network SecurityInstallation aid PowerConnectors Performance ConsiderationsAxis Q6044 PTZ Dome Network Camera M4.2