Axis Communications Q1614-E Reset to Factory Default Settings, File Upload, Plain Config

Page 60

AXIS Q1614-E Network Camera

System Options

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 60.

For more information, see www.axis.com/developer

File Upload

Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

Note

The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup

To reset the product to the factory default settings:

1.Disconnect power from the product.

2.Press and hold the control button and reconnect power. See Hardware Overview on page 6 .

3.Keep the control button pressed for about 15–30 seconds until the status LED indicator flashes amber.

4.Release the control button. The process is complete when the status LED indicator turns green. The product has been reset to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90

5.Using the installation and management software tools, assign an IP address, set the password, and access the video stream.

6.Refocus the product.

It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

60

Image 60
Contents Axis Q1614-E Network Camera About this Document Legal ConsiderationsLiability Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q1614-E Network CameraConnectors Performance Considerations Hardware Overview Axis Q1614-E Network Camera Connectors and Buttons Network ConnectorConnector For technical specifications, seeLED Indicators Buzzer Signal for Focus Assistant Status LED Behavior for Focus AssistantColor BuzzerReplace the Lens Color Buzzer Camera positionAccess the Product Access from a BrowserAccess from the Internet Set the Root PasswordPTZ Mode Configure Capture ModeSet Power Line Frequency Live ViewGo to Setup Events Controls on the Live ViewManual Trigger To show the manual trigger buttons in the Live ViewAxis Media Control viewer toolbar PTZ ControlsAMC Audio Controls Axis Q1614-E Network Camera How to Stream H.264 Media StreamsAxis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccess Audio Streams Java applet supports simplex audio with G.711 encodingSet Up the Product Basic SetupFocus Adjustment Video and Audio Video StreamPixel Counter ImageClick Save to apply the new settings Stream Profiles264 Camera Settings Capture ModeGo to Setup Video & Audio Camera Settings Lightfinder Mode Exposure SettingsImage Appearance White BalanceIris configuration Iris adjustmentSet Shutter to Day/NightTo configure the view area View AreaOverlay Go to Video & Audio Video Stream and select the Image tabOverlay Image Use Overlay Text in an Action RuleGo to Video & Audio Overlay Image Privacy Mask FocusGo to Events Action Rules BasicAudio Settings Audio ModesAudio Input Audio Clips Audio OutputConfigure the Live View Default Viewer for BrowsersViewer Settings Browser Viewer DescriptionGo to Setup Live View Config User Defined LinksOutput Buttons For more information about I/O ports, see I/O Ports onPreset Positions Go to PTZ Preset PositionsPTZ Pan Tilt Zoom Guard TourInstall PTZ Driver Device SettingsAdvanced Control QueueOperator Same as administrator but with lower priority Detectors Camera TamperingMotion Detection Shock DetectionSet Up Motion Detection Windows Motion Detection ParametersGo to Detectors Motion Detection Parameter Object Size History Sensitivity DescriptionAudio Detection Install Application Go to Setup ApplicationsApplications Application LicensesAxis Q1614-E Network Camera Set Up Action Rules EventsTriggers Go to Events Action Rules and click AddActions Set Up Email Recipients Add RecipientsPTZ Control Go to Events Recipients and click AddSet Up Recurrences Create SchedulesTo create a new schedule Go to Events Schedules and click AddRecordings Find RecordingsPlay Recording Go to Recordings ListExport Video Clip Continuous RecordingTo play a recording, follow these steps Go to Recordings ContinuousLanguages System Options SecurityUsers IP Address FilterIeee CertificatesGo to System Options Security Ieee To install a self-signed certificate Go to Setup System Options Security CertificatesClick Install certificate and upload the certificate Date & TimeBasic TCP/IP Settings NetworkAdvanced TCP/IP Settings Axis Internet Dynamic DNS ServiceAxis Internet Dynamic DNS Service requires IPv4 DNS ConfigurationNTP Configuration Host Name ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4QoS Quality of Service FTPUPnPTM can be disabled under System Options Network UPnPTM UPnPTMRTP/H.264 Storage BonjourSD Card Mount and Unmount SD CardUnder General Settings, select Autoformat to Network ShareTo add a network share Go to System Options Storage Click Network ShareMaintenance Ports & DevicesSupport Support OverviewSystem Overview Logs & ReportsReset to Factory Default Settings Plain ConfigFile Upload Troubleshooting Upgrade the FirmwareEmergency Recovery Procedure Check the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externallyProblems with streaming H.264 Status and Network indicator LEDs are flashing red rapidlyVideo and image problems, general Setup Video & Audio Camera SettingsSettings Storage and disk management problemsNo audio Poor audio qualityTechnical Specifications Function/group Specifications Audio Audio streaming Audio inputAudio output Network SecurityFunction/group Specifications PowerConnectors DimensionsConnectors RS485/422 Connector Performance ConsiderationsOutput Function PinAxis Q1614-E Network Camera M5.5