Axis Communications P5522 Multi-Connector Cable sold separately, Function Pin Specifications

Page 47

AXIS P5522 PTZ Dome Network Camera

Multi-Connector Cable (sold separately)

Multi-Connector Cable (sold separately)

When connecting external equipment to the Axis product, a multi-connector cable (available from Axis) is required in order to maintain the product’s IP rating. The multi-connector cable can be purchased from your Axis reseller.

Connect the multi-connector cable to the product’s multi-connector (see page 4 ). The cable provides the following connectors:

Note

See page 53 for technical specifications.

Power connector - 3-pin terminal block used for power input. See image below.

Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).

Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio out.

I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:

Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Event Type. The output will show as active (shown under Events > Port Status) if the alarm device is activated.

Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Events > Port Status).

Function

Pin

Notes

Specifications

 

 

 

 

GND

1

Ground

 

 

 

 

 

3.3 V DC Power

2

Can be used to power auxiliary equipment.

Max load = 250 mA

 

 

Note: This pin can only be used as power out.

 

 

 

 

 

Configurable

3–6

Digital input — Connect to GND to activate, or leave floating

0 to +40 V DC

(Input or Output)

 

(unconnected) to deactivate.

 

 

 

Digital output — Internal connection to ground when

Max load =100 mA

 

 

activated, floating (unconnected) when deactivated. If used

Max voltage = +40 V DC

 

 

with an external relay, a diode must be connected in parallel

 

 

 

with the load, for protection against voltage transients.

 

 

 

 

 

47

Image 47
Contents Axis P5522 PTZ Dome Network Camera Equipment Modifications About this documentLiability Intellectual Property RightsAxis P5522 PTZ Dome Network Camera Table of contentsHardware overview ConnectorsHardware overview Color Indication LED indicatorsStart a browser Internet Explorer, Firefox, Safari Accessing the productAccessing the product Access from a browserClick Create self-signed certificate Access from the InternetSet the root password Network TCP/IP AdvancedAxis Media Control viewer toolbar Live ViewControls on the Live View AMC Audio controls PTZ ControlsAxis P5522 PTZ Dome Network Camera Axis Media Control AMC How to stream H.264Media streams Media streamsQuickTimeTM. The following paths can be used Alternative methods of accessing the video streamJava applet supports simplex audio with G.711 encoding Accessing audio streamsBasic Setup Setting up the productSetting up the product Image Video and AudioVideo and Audio Video StreamImage Appearance Camera SettingsStream Profiles 264Wide Dynamic Range Exposure SettingsImage settings White balanceOverlay image Audio SettingsOverlay Privacy MaskAudio Output Audio InputAudio Clips Live View Config Default viewer for browsersLive View Config Browser Viewer Description Viewer SettingsUser Defined Links Output ButtonsAxis P5522 PTZ Dome Network Camera Guard Tour Preset positionsPTZ Pan Tilt Zoom PTZ Pan Tilt ZoomGo to PTZ Guard Tour and click Add Osdi ZonesAdvanced LimitsSee the online help for more information Operator Same as administrator but with lower priorityControl Queue ControlsApplications ApplicationsServer type Purpose Information required EventsEvents Event ServersGo to Events Event Types and click Add triggered Set up a triggered eventEvent Types Go to Events Event Types and click Add scheduled Set up a scheduled eventSave stream Go to Events Motion Detection Set up motion detectionGatekeeper Motion detectionMotion detection parameters Go to Events Audio Detection Audio detectionPort Status Event recordings RecordingsRecordings Go to Recordings Continuous Continuous recordingAxis P5522 PTZ Dome Network Camera Security System OptionsSystem Options Audio Support Date & TimeNetwork Basic TCP/IP SettingsNTP Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service DNS ConfigurationNAT traversal port mapping for IPv4 Link-Local IPv4 AddressSmtp email QoS Quality of ServiceBonjour StorageUPnPTM RTP/H.264Support MaintenancePorts & Devices File Upload ScriptingPlain Config Reset to factory default settingsFunction Pin Specifications Multi-Connector Cable sold separatelyMulti-Connector Cable sold separately Connector DC power input Connection diagramChecking the firmware TroubleshootingTroubleshooting Emergency recovery procedureProduct is accessible locally but not externally Symptoms, possible causes and remedial actionsProblems setting the IP address Camera cannot be accessed from a browserKey frames Problems with the H.264 formatVideo and image problems, general Video & Audio Camera SettingsOverlay image is not displayed Problems uploading filesSettings Storage and disk management problemsTechnical Specifications Technical SpecificationsMaintenance General Casing Alarm triggersAlarm events InstallationPerformance considerations M2.4