Bosch Appliances NBC-265-W operation manual Device Access, Camera name, Password, Live

Page 29

IP Camera 200 Series

Basic Mode en 65

 

 

5.2Device Access

5.2.1Camera name

The camera can be assigned a name to assist in identifying it. The name simplifies the management of multiple devices in more extensive systems.

The camera name is used for remote identification, for example, in the event of an alarm. Enter a name that makes it as easy as possible to identify the location unambiguously.

5.2.2Password

A password prevents unauthorized access to the device. The device recognizes three authorization levels: service, user, and

live.

service is the highest authorization level. Entering the correct password gives access to all the functions of the camera and allows all configuration settings to be changed.

user is the middle authorization level. This user can operate the device, play back recordings, and also control a camera but cannot change the configuration.

live is the lowest authorization level. It can only be used to view the live video image and switch between the different live image displays.

Use the various authorization levels to limit access. Proper password protection is only guaranteed if all higher authorization levels are also protected with a password. For example, if a live password is assigned, a service and a user password should also be set. When assigning passwords, always start from the highest authorization level, service, and use different passwords.

Password

Define and change a separate password for each level while logged in as service or if the device is not protected by a password. Enter the password (19 characters maximum) for the selected level.

Bosch Security Systems

Installation and Operation Manual AR18-10-B012 v1.54 2011.08

Image 29
Contents HD 720p IP Wireless Camera Page Table of Contents Advanced Mode Basic ModeOperation via the browser 132 Troubleshooting 140Technical Data 143 Maintenance 142Safety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceDisclaimer UL certificationFCC RF Radiation Exposure Statement More information CE certificationBosch notices Copyrights Introduction FeaturesCD ROM UnpackingWireless antenna InstallationSD card SD cardMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraSystem requirements Browser connectionProtected network Password protection in cameraEstablishing the connection Connection established SettingsLivepage RecordingsEn Browser connection IP Camera 200 Series Saving changes Basic ModeBasic Mode menu tree Password Device AccessPassword Camera nameDevice date, time and zone Confirm passwordDate/Time Network Click Set and RebootIP address Subnet maskAudio EncoderRecording System OverviewAdvanced Mode menu tree Advanced ModeIdentification GeneralPassword Date format Date/TimeDevice date / Device time Device time zoneTime server IP address Display StampingTime server type Camera name stampingAlarm message Alarm mode stampingTime stamping Display millisecondsAppearance Web InterfaceLivepage Functions Logging Camera Installer MenuPicture Settings Default Encoder Streams Audio Recording Device manager Storage ManagementRecording media ISCSI MediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaRecording Profiles Stream profile settingsRecording includes Standard recordingAlarm recording Retention Time Holidays Recording SchedulerWeekdays Profile names Recording StatusActivate recording Recording statusAlarm Connections AlarmVideo transmission Select 10 in the Number of destination IP address list boxStream Remote portAuto-connect DecoderSSL encryption Video Content Analyses VCA Aggregation time s VCA configuration- ProfilesSensitivity Analysis typeMotion detector Debounce time 1 s Minimum object sizeSelecting the area Tamper detectionGlobal change slider Trigger delay sGlobal change Scene too brightReference check Scene too darkScene too noisy Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Delay s VCA configuration Event triggeredTrigger Trigger activeAudio alarm Audio AlarmSignal Ranges NameAlarm E-Mail Test e-mail Destination addressSender name Relay Alarm inputInterfaces Trigger relay Relay followsRelay name Automatic IP assignment Network AccessDetails Video transmission DNS server addressHttp browser port Https browser portEnable DynDNS Interface mode ETHRCP+ port Telnet supportUser name Host nameForce registration now StatusAdvanced AuthenticationSnmp host address / 2. Snmp host address Snmp trapsRtsp port WlanUPnP TCP metadata inputMulticast Address EnableMulticast FTP Posting FTP server password FTP server loginFTP server IP address Path on FTP serverMaintenance ServiceService FirmwareSSL certificate ConfigurationSystem Overview Maintenance logProcessor load Operation via the browserLivepage Image selection System Log / Event Log Digital I/ORecording video sequences Saving snapshotsRunning recording program Audio communicationEn Operation via the browser IP Camera 200 Series Controlling playback RecordingsSelecting Recordings Export to FTPBookmarks Slide controlLED indicators TroubleshootingResolving problems Customer serviceIP Camera 200 Series Troubleshooting en Transfer and disposal MaintenanceRepairs Specifications Technical DataWPA-PSKTKIP, WPA2-PSKAES Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems