IP Camera 200 Series

Advanced Mode en 119

 

 

6.9Service

Service

>Maintenance

>System Overview

6.9.1Maintenance

CAUTION!

Before starting a firmware update, make sure to select the correct upload file. Uploading the wrong files can result in the device no longer being addressable, requiring it to be replaced. Do not interrupt the firmware installation. Even changing to another page or closing the browser window leads to interruption. Interruption may lead to faulty coding of the Flash memory. This can result in the device no longer being addressable, requiring it to be replaced.

Firmware

The camera functions and parameters can be updated by uploading new firmware. To do this, the latest firmware package is transferred to the device via the network. The firmware is installed there automatically. Thus, a camera can be serviced and updated remotely without requiring a technician to make changes to the device on site. The latest firmware can be obtained from your customer service center or from the Bosch Security Systems download area.

To update the firmware:

1.First, store the firmware file on your hard disk.

2.Enter the full path for the firmware file in the field or click Browse to locate and select the file.

3.Click Upload to begin transferring the file to the device. The progress bar allows monitoring of the transfer.

The new firmware is unpacked and the Flash memory is reprogrammed. The time remaining is shown by the message going to reset Reconnecting in ... seconds. When the upload is completed successfully, the device reboots automatically.

Bosch Security Systems

Installation and Operation Manual AR18-10-B012 v1.54 2011.08

Image 83
Contents HD 720p IP Wireless Camera Page Table of Contents Advanced Mode Basic ModeOperation via the browser 132 Troubleshooting 140Technical Data 143 Maintenance 142Safety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceDisclaimer UL certificationFCC RF Radiation Exposure Statement More information CE certificationBosch notices Copyrights Introduction FeaturesCD ROM UnpackingWireless antenna InstallationSD card SD cardMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraSystem requirements Browser connectionProtected network Password protection in cameraEstablishing the connection Recordings SettingsConnection established LivepageEn Browser connection IP Camera 200 Series Saving changes Basic ModeBasic Mode menu tree Camera name Device AccessPassword PasswordDevice date, time and zone Confirm passwordDate/Time Subnet mask Click Set and RebootNetwork IP addressSystem Overview EncoderAudio RecordingAdvanced Mode menu tree Advanced ModeIdentification GeneralPassword Device time zone Date/TimeDate format Device date / Device timeCamera name stamping Display StampingTime server IP address Time server typeDisplay milliseconds Alarm mode stampingAlarm message Time stampingAppearance Web InterfaceLivepage Functions Logging Camera Installer MenuPicture Settings Default Encoder Streams Audio Recording ISCSI Media Storage ManagementDevice manager Recording mediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaStandard recording Stream profile settingsRecording Profiles Recording includesAlarm recording Retention Time Holidays Recording SchedulerWeekdays Recording status Recording StatusProfile names Activate recordingAlarm Connections AlarmRemote port Select 10 in the Number of destination IP address list boxVideo transmission StreamAuto-connect DecoderSSL encryption Video Content Analyses VCA Aggregation time s VCA configuration- ProfilesSensitivity Analysis typeMotion detector Tamper detection Minimum object sizeDebounce time 1 s Selecting the areaScene too bright Trigger delay sGlobal change slider Global changeReference check Scene too darkScene too noisy Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Trigger active VCA configuration Event triggeredDelay s TriggerName Audio AlarmAudio alarm Signal RangesAlarm E-Mail Test e-mail Destination addressSender name Relay Alarm inputInterfaces Trigger relay Relay followsRelay name Automatic IP assignment Network AccessHttps browser port DNS server addressDetails Video transmission Http browser portTelnet support Interface mode ETHEnable DynDNS RCP+ portStatus Host nameUser name Force registration nowSnmp traps AuthenticationAdvanced Snmp host address / 2. Snmp host addressTCP metadata input WlanRtsp port UPnPMulticast Address EnableMulticast FTP Posting Path on FTP server FTP server loginFTP server password FTP server IP addressFirmware ServiceMaintenance ServiceSSL certificate ConfigurationSystem Overview Maintenance logProcessor load Operation via the browserLivepage Image selection System Log / Event Log Digital I/OAudio communication Saving snapshotsRecording video sequences Running recording programEn Operation via the browser IP Camera 200 Series Export to FTP RecordingsControlling playback Selecting RecordingsBookmarks Slide controlCustomer service TroubleshootingLED indicators Resolving problemsIP Camera 200 Series Troubleshooting en Transfer and disposal MaintenanceRepairs Specifications Technical DataWPA-PSKTKIP, WPA2-PSKAES Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems