Bosch Appliances NBC-265-W operation manual FTP Posting

Page 81

IP Camera 200 Series

Advanced Mode en 117

 

 

Duplication of data places a heavy demand on the CPU and can lead to impairment of the image quality under certain circumstances.

Port

Enter the port address for the stream here.

Streaming

Click the checkbox to activate multicast streaming mode. An activated stream is marked with a check. (Streaming is typically not required for standard multicast operation.)

Multicast packet TTL

A value can be entered to specify how long the multicast data packets are active on the network. If multicast is to be run via a router, the value must be greater than 1.

6.8.5FTP Posting

Save individual JPEG images on an FTP server at specific intervals. If required, retrieve these images at a later date to reconstruct alarm events. JPEG resolution corresponds to the highest setting from the two data streams.

File name

Select how file names are created for the individual images that are transmitted.

Overwrite: The same file name is always used and any existing file will be overwritten by the current file.

Increment: A number from 000 to 255 is added to the file name and automatically incremented by 1. When it reaches 255, it starts again from 000.

Date/time suffix: The date and time are automatically added to the file name. When setting this parameter, ensure that the date and time of the device are always set correctly . For eample, the file snap011005_114530.jpg was stored on October 1, 2005 at 11.45 and 30 seconds.

Posting interval

Enter the interval in seconds at which the images are sent to an FTP server. Enter zero for no images to be sent.

Bosch Security Systems

Installation and Operation Manual AR18-10-B012 v1.54 2011.08

Image 81
Contents HD 720p IP Wireless Camera Page Table of Contents Advanced Mode Basic ModeOperation via the browser 132 Troubleshooting 140Technical Data 143 Maintenance 142Safety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceUL certification FCC RF Radiation Exposure StatementDisclaimer CE certification Bosch noticesMore information Copyrights Introduction FeaturesCD ROM UnpackingWireless antenna InstallationSD card SD cardMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraSystem requirements Browser connectionPassword protection in camera Establishing the connectionProtected network Connection established SettingsLivepage RecordingsEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Password Device AccessPassword Camera nameConfirm password Date/TimeDevice date, time and zone Network Click Set and RebootIP address Subnet maskAudio EncoderRecording System OverviewAdvanced Mode menu tree Advanced ModeIdentification GeneralPassword Date format Date/TimeDevice date / Device time Device time zoneTime server IP address Display StampingTime server type Camera name stampingAlarm message Alarm mode stampingTime stamping Display millisecondsAppearance Web InterfaceLivepage Functions Logging Camera Installer MenuPicture Settings Default Encoder Streams Audio Recording Device manager Storage ManagementRecording media ISCSI MediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaRecording Profiles Stream profile settingsRecording includes Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Profile names Recording StatusActivate recording Recording statusAlarm Connections AlarmVideo transmission Select 10 in the Number of destination IP address list boxStream Remote portDecoder SSL encryptionAuto-connect Video Content Analyses VCA Aggregation time s VCA configuration- ProfilesAnalysis type Motion detectorSensitivity Debounce time 1 s Minimum object sizeSelecting the area Tamper detectionGlobal change slider Trigger delay sGlobal change Scene too brightScene too dark Scene too noisyReference check Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Delay s VCA configuration Event triggeredTrigger Trigger activeAudio alarm Audio AlarmSignal Ranges NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Automatic IP assignment Network AccessDetails Video transmission DNS server addressHttp browser port Https browser portEnable DynDNS Interface mode ETHRCP+ port Telnet supportUser name Host nameForce registration now StatusAdvanced AuthenticationSnmp host address / 2. Snmp host address Snmp trapsRtsp port WlanUPnP TCP metadata inputEnable MulticastMulticast Address FTP Posting FTP server password FTP server loginFTP server IP address Path on FTP serverMaintenance ServiceService FirmwareSSL certificate ConfigurationSystem Overview Maintenance logOperation via the browser LivepageProcessor load Image selection System Log / Event Log Digital I/ORecording video sequences Saving snapshotsRunning recording program Audio communicationEn Operation via the browser IP Camera 200 Series Controlling playback RecordingsSelecting Recordings Export to FTPBookmarks Slide controlLED indicators TroubleshootingResolving problems Customer serviceIP Camera 200 Series Troubleshooting en Maintenance RepairsTransfer and disposal Specifications Technical DataWPA-PSKTKIP, WPA2-PSKAES Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems