Bosch Appliances NBC-265-W Advanced, Snmp host address / 2. Snmp host address, Snmp traps

Page 78

114 en Advanced Mode

IP Camera 200 Series

 

 

6.8.2Advanced

The settings on this page are used to set advanced settings the network. Some changes only take effect after a reboot. In this case Set changes to Set and Reboot.

1.Make the desired changes.

2.Click Set and Reboot.

The device is rebooted and the changed settings are activated.

SNMP

The camera supports the SNMP V2 (Simple Network Management Protocol) for managing and monitoring network components, and can send SNMP messages (traps) to IP addresses. It supports SNMP MIB II in the unified code.

If On is selected for the SNMP parameter and a SNMP host address is not entered, the device does not send the traps automatically and will only reply to SNMP requests. If one or two SNMP host addresses are entered, SNMP traps are sent automatically. Select Off to deactivate the SNMP function.

1. SNMP host address / 2. SNMP host address

To send SNMP traps automatically, enter the IP addresses of one or two target devices here.

SNMP traps

To choose which traps are sent:

1.Click Select. A dialog box appears.

2.Click the check boxes of the appropriate traps.

3.Click Set to close the window and send all of the checked traps.

Authentication (802.1x)

To configure Radius server authentication, connect the camera directly to a computer using a network cable. If a Radius server controls access rights over the network, select On to activate authentication to communicate with the device.

1.Enter the user name that the Radius server uses for the camera in the Identity field.

2.Enter the Password that the Radius server expects from the camera.

AR18-10-B012 v1.54 2011.08 Installation and Operation Manual

Bosch Security Systems

Image 78
Contents HD 720p IP Wireless Camera Page Table of Contents Basic Mode Advanced ModeTroubleshooting 140 Operation via the browser 132Maintenance 142 Technical Data 143Safety Safety precautionsImportant safety instructions FCC & Ices compliance FCC & Ices InformationUL certification FCC RF Radiation Exposure StatementDisclaimer CE certification Bosch noticesMore information Copyrights Features IntroductionUnpacking CD ROMInstallation Wireless antennaSD card SD cardMounting the camera Mounting a cameraIP Camera 200 Series Installation en Network connector Network connectionPower connection DC power connectionI/O connector Function Pin SocketAudio connectors Audio connectorsResetting the camera Reset buttonBrowser connection System requirementsPassword protection in camera Establishing the connectionProtected network Livepage SettingsConnection established RecordingsEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Password Device AccessPassword Camera nameConfirm password Date/TimeDevice date, time and zone IP address Click Set and RebootNetwork Subnet maskRecording EncoderAudio System OverviewAdvanced Mode Advanced Mode menu treeGeneral IdentificationPassword Device date / Device time Date/TimeDate format Device time zoneTime server type Display StampingTime server IP address Camera name stampingTime stamping Alarm mode stampingAlarm message Display millisecondsWeb Interface AppearanceLivepage Functions Logging Installer Menu CameraPicture Settings Default Encoder Streams Audio Recording Recording media Storage ManagementDevice manager ISCSI MediaActivating and Configuring Storage Media Formatting Storage Media Deactivating Storage MediaRecording includes Stream profile settingsRecording Profiles Standard recordingAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Activate recording Recording StatusProfile names Recording statusAlarm Alarm ConnectionsStream Select 10 in the Number of destination IP address list boxVideo transmission Remote portDecoder SSL encryptionAuto-connect Video Content Analyses VCA VCA configuration- Profiles Aggregation time sAnalysis type Motion detectorSensitivity Selecting the area Minimum object sizeDebounce time 1 s Tamper detectionGlobal change Trigger delay sGlobal change slider Scene too brightScene too dark Scene too noisyReference check Appearing edges VCA configuration Scheduled Deleting HolidaysIP Camera 200 Series Advanced Mode en Trigger VCA configuration Event triggeredDelay s Trigger activeSignal Ranges Audio AlarmAudio alarm NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Network Access Automatic IP assignmentHttp browser port DNS server addressDetails Video transmission Https browser portRCP+ port Interface mode ETHEnable DynDNS Telnet supportForce registration now Host nameUser name StatusSnmp host address / 2. Snmp host address AuthenticationAdvanced Snmp trapsUPnP WlanRtsp port TCP metadata inputEnable MulticastMulticast Address FTP Posting FTP server IP address FTP server loginFTP server password Path on FTP serverService ServiceMaintenance FirmwareConfiguration SSL certificateMaintenance log System OverviewOperation via the browser LivepageProcessor load Image selection Digital I/O System Log / Event LogRunning recording program Saving snapshotsRecording video sequences Audio communicationEn Operation via the browser IP Camera 200 Series Selecting Recordings RecordingsControlling playback Export to FTPSlide control BookmarksResolving problems TroubleshootingLED indicators Customer serviceIP Camera 200 Series Troubleshooting en Maintenance RepairsTransfer and disposal Technical Data SpecificationsWPA-PSKTKIP, WPA2-PSKAES Dimensions AccessoriesEn Technical Data IP Camera 200 Series Page Bosch Security Systems