Bosch Appliances NBC-265-W Recording Profiles, Stream profile settings, Recording includes

Page 51

IP Camera 200 Series

Advanced Mode en 87

 

 

6.5.2Recording Profiles

Define up to ten different recording profiles here, then assign these to individual days or times of day on the Recording Scheduler page. Modify the names of the recording profiles on the tabs in the Recording Scheduler page.

1.Click a tab to edit the corresponding profile.

2.If necessary, click Default to return all settings to their defaults.

3.Click Copy Settings to copy the currently visible settings to other profiles. A window opens to select the target profiles for the copied settings.

4.For each profile, click Set to save.

Stream profile settings

Select the profile setting that is to be used for each data stream when recording. This selection is independent of the selection for live data stream transmission. (The properties of the profiles are defined on the Encoder Profile page.)

Recording includes

Specify whether, in addition to video data, audio or metadata (for example alarms or VCA data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity. Without metadata, it is not possible to include video content analysis in recordings.

Standard recording

Select the mode for standard recordings:

Continuous: the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten.

Pre-alarm: recording takes place in the pre-alarm time, during the alarm and during the post-alarm time only.

Off: no automatic recording takes place.

In the Stream list box, select Stream 1, Stream 2 or I-frames only for standard recordings.

Bosch Security Systems

Installation and Operation Manual AR18-10-B012 v1.54 2011.08

Image 51
Contents HD 720p IP Wireless Camera Page Table of Contents Advanced Mode Basic ModeOperation via the browser 132 Troubleshooting 140Technical Data 143 Maintenance 142Safety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceUL certification FCC RF Radiation Exposure StatementDisclaimer CE certification Bosch noticesMore information Copyrights Introduction FeaturesCD ROM UnpackingWireless antenna InstallationSD card SD cardMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraSystem requirements Browser connectionPassword protection in camera Establishing the connectionProtected network Recordings SettingsConnection established LivepageEn Browser connection IP Camera 200 Series Basic Mode Basic Mode menu treeSaving changes Camera name Device AccessPassword PasswordConfirm password Date/TimeDevice date, time and zone Subnet mask Click Set and RebootNetwork IP addressSystem Overview EncoderAudio RecordingAdvanced Mode menu tree Advanced ModeIdentification GeneralPassword Device time zone Date/TimeDate format Device date / Device timeCamera name stamping Display StampingTime server IP address Time server typeDisplay milliseconds Alarm mode stampingAlarm message Time stampingAppearance Web InterfaceLivepage Functions Logging Camera Installer MenuPicture Settings Default Encoder Streams Audio Recording ISCSI Media Storage ManagementDevice manager Recording mediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaStandard recording Stream profile settingsRecording Profiles Recording includesAlarm recording Retention Time Recording Scheduler WeekdaysHolidays Recording status Recording StatusProfile names Activate recordingAlarm Connections AlarmRemote port Select 10 in the Number of destination IP address list boxVideo transmission StreamDecoder SSL encryptionAuto-connect Video Content Analyses VCA Aggregation time s VCA configuration- ProfilesAnalysis type Motion detectorSensitivity Tamper detection Minimum object sizeDebounce time 1 s Selecting the areaScene too bright Trigger delay sGlobal change slider Global changeScene too dark Scene too noisyReference check Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Trigger active VCA configuration Event triggeredDelay s TriggerName Audio AlarmAudio alarm Signal RangesAlarm E-Mail Destination address Sender nameTest e-mail Alarm input InterfacesRelay Relay follows Relay nameTrigger relay Automatic IP assignment Network AccessHttps browser port DNS server addressDetails Video transmission Http browser portTelnet support Interface mode ETHEnable DynDNS RCP+ portStatus Host nameUser name Force registration nowSnmp traps AuthenticationAdvanced Snmp host address / 2. Snmp host addressTCP metadata input WlanRtsp port UPnPEnable MulticastMulticast Address FTP Posting Path on FTP server FTP server loginFTP server password FTP server IP addressFirmware ServiceMaintenance ServiceSSL certificate ConfigurationSystem Overview Maintenance logOperation via the browser LivepageProcessor load Image selection System Log / Event Log Digital I/OAudio communication Saving snapshotsRecording video sequences Running recording programEn Operation via the browser IP Camera 200 Series Export to FTP RecordingsControlling playback Selecting RecordingsBookmarks Slide controlCustomer service TroubleshootingLED indicators Resolving problemsIP Camera 200 Series Troubleshooting en Maintenance RepairsTransfer and disposal Specifications Technical DataWPA-PSKTKIP, WPA2-PSKAES Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems