Bosch Appliances NBC-265-W operation manual Activating and Configuring Storage Media

Page 49

IP Camera 200 Series

Advanced Mode en 85

 

 

Note:

If a device had primary and secondary recording running on the SD card and is then added to a VRM system, the blocks used for primary recording will not be re-used, reducing the available recording space for ANR recording. This can be solved by re- formatting the SD card.

Throughput limit for simultaneous recording and local replay at

100% playback speed is:

maximum total recording bit rate of 7 Mbps for external iSCSI recording.

maximum total recording bit rate of 10 Mbps for SD card recording, depending on SD card performance.

Activating and Configuring Storage Media

The storage overview displays the available storage media. Select individual media or iSCSI drives and transfer these to the Managed storage media list. Activate the storage media in this list and configure them for storage.

Note:

Each storage medium can only be associated with one user. If a storage medium is already being used by another user, decouple the user and connect the drive to the camera. Before decoupling, make absolutely sure that the previous user no longer needs the storage medium.

1.In the Recording media section, click the iSCSI Media or Local Media tab to display the applicable storage media in the overview.

2.In the Storage overview section, double-click the required storage medium, a SD card, an iSCSI LUN or one of the other available drives. The medium is then added to the Managed storage media list. Newly added media is indicated in the Status column by the status Not active.

3.Click Set to activate all media in the Managed storage media list. These are indicated in the Status column by the status Online.

Bosch Security Systems

Installation and Operation Manual AR18-10-B012 v1.54 2011.08

Image 49
Contents HD 720p IP Wireless Camera Page Table of Contents Advanced Mode Basic ModeOperation via the browser 132 Troubleshooting 140Technical Data 143 Maintenance 142Safety precautions SafetyImportant safety instructions FCC & Ices Information FCC & Ices complianceFCC RF Radiation Exposure Statement UL certificationDisclaimer Bosch notices CE certificationMore information Copyrights Introduction FeaturesCD ROM UnpackingWireless antenna InstallationSD card SD cardMounting a camera Mounting the cameraIP Camera 200 Series Installation en Network connection Network connectorDC power connection Power connectionFunction Pin Socket I/O connectorAudio connectors Audio connectorsReset button Resetting the cameraSystem requirements Browser connectionEstablishing the connection Password protection in cameraProtected network Connection established SettingsLivepage RecordingsEn Browser connection IP Camera 200 Series Basic Mode menu tree Basic ModeSaving changes Password Device AccessPassword Camera nameDate/Time Confirm passwordDevice date, time and zone Network Click Set and RebootIP address Subnet maskAudio EncoderRecording System OverviewAdvanced Mode menu tree Advanced ModeIdentification GeneralPassword Date format Date/TimeDevice date / Device time Device time zoneTime server IP address Display StampingTime server type Camera name stampingAlarm message Alarm mode stampingTime stamping Display millisecondsAppearance Web InterfaceLivepage Functions Logging Camera Installer MenuPicture Settings Default Encoder Streams Audio Recording Device manager Storage ManagementRecording media ISCSI MediaActivating and Configuring Storage Media Deactivating Storage Media Formatting Storage MediaRecording Profiles Stream profile settingsRecording includes Standard recordingAlarm recording Retention Time Weekdays Recording SchedulerHolidays Profile names Recording StatusActivate recording Recording statusAlarm Connections AlarmVideo transmission Select 10 in the Number of destination IP address list boxStream Remote portSSL encryption DecoderAuto-connect Video Content Analyses VCA Aggregation time s VCA configuration- ProfilesMotion detector Analysis typeSensitivity Debounce time 1 s Minimum object sizeSelecting the area Tamper detectionGlobal change slider Trigger delay sGlobal change Scene too brightScene too noisy Scene too darkReference check Appearing edges Deleting Holidays VCA configuration ScheduledIP Camera 200 Series Advanced Mode en Delay s VCA configuration Event triggeredTrigger Trigger activeAudio alarm Audio AlarmSignal Ranges NameAlarm E-Mail Sender name Destination addressTest e-mail Interfaces Alarm inputRelay Relay name Relay followsTrigger relay Automatic IP assignment Network AccessDetails Video transmission DNS server addressHttp browser port Https browser portEnable DynDNS Interface mode ETHRCP+ port Telnet supportUser name Host nameForce registration now StatusAdvanced AuthenticationSnmp host address / 2. Snmp host address Snmp trapsRtsp port WlanUPnP TCP metadata inputMulticast EnableMulticast Address FTP Posting FTP server password FTP server loginFTP server IP address Path on FTP serverMaintenance ServiceService FirmwareSSL certificate ConfigurationSystem Overview Maintenance logLivepage Operation via the browserProcessor load Image selection System Log / Event Log Digital I/ORecording video sequences Saving snapshotsRunning recording program Audio communicationEn Operation via the browser IP Camera 200 Series Controlling playback RecordingsSelecting Recordings Export to FTPBookmarks Slide controlLED indicators TroubleshootingResolving problems Customer serviceIP Camera 200 Series Troubleshooting en Repairs MaintenanceTransfer and disposal Specifications Technical DataWPA-PSKTKIP, WPA2-PSKAES Accessories DimensionsEn Technical Data IP Camera 200 Series Page Bosch Security Systems