Axis Communications M3014 Reset to factory default settings, Scripting, File Upload, Plain Config

Page 40

AXIS M3014 Network Camera

System Options

Parameter List - Shows the product's parameters and their current settings. This may prove useful when troubleshooting or when contacting Axis Support.

Connection List - Lists all clients that are currently accessing media streams.

Crash Report - Generates an archive with debugging information. The report takes several minutes to generate.

The log levels for the System Log and the Access Log are set under System Options > Support > Logs & Reports > Configuration. The Access Log can be configured to list all connections to the product (select Critical, Warnings & Info). If required, a different log level can be used when sending emails.

Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

Caution

Improper use may cause unexpected behavior and loss of contact with the Axis product.

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. It is recommended to create a backup file before customizing the scripts. If a script causes problems, reset the product to its factory default settings, see page 40.

For more information, see www.axis.com/developer

File Upload

Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page. Help is available from the standard help pages.

To open Plain Config, go to System Options > Advanced > Plain Config.

Reset to factory default settings

This will reset all parameters, including the IP address, to the factory default settings:

1.Disconnect power from the product.

2.Press and hold the Control button and reconnect power (see Hardware overview, on page 4 ).

3.Keep the Control button pressed for about 15 seconds until the Status indicator flashes amber.

4.Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The product has been reset to the factory default settings. The default IP address is 192.168.0.90

5.Re-assign the IP address.

It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

40

Image 40
Contents Axis M3014 Network Camera About this document LiabilityIntellectual Property Rights Equipment ModificationsTable of Contents Axis M3014 Network CameraHardware overview Hardware overviewConnectors LED indicatorsMaintenance Color IndicationAccessing the product Accessing the productAccess from a browser Access from the Internet Set the root passwordNetwork TCP/IP Advanced Click Create self-signed certificateLive View Set Power Line FrequencyControls on the Live View Axis Media Control viewer toolbar PTZ ControlsHow to stream H.264 Media streamsMedia streams Axis Media Control AMCAlternative methods of accessing the video stream Axis M3014 Network Camera Setting up the product Setting up the productBasic Setup Video VideoVideo Stream Pixel CounterImage Stream Profiles264 Camera Settings Exposure SettingsView Area Image AppearancePrivacy Mask OverlayOverlay image Live View Config Default viewer for browsersLive View Config User Defined Links Viewer SettingsBrowser Viewer Description Preset Positions PTZ Pan Tilt ZoomPTZ Pan Tilt Zoom Guard TourAdvanced ControlsDetectors DetectorsCamera Tampering Motion DetectionSet up motion detection Motion detection parametersLow level 0% Default valuesRecommended values Applications ApplicationsEvents EventsConvert Event Types to Action Rules Setting Up an Action RuleGo to Events Action Rules and click Add Schedules RecipientsRecurrences Axis M3014 Network Camera Recordings RecordingsRecording List Continuous recordingAxis M3014 Network Camera System Options System OptionsSecurity UsersDate & Time IeeeBasic TCP/IP Settings NetworkAdvanced TCP/IP Settings Http NAT traversal port mapping for IPv4QoS Quality of Service Smtp emailStorage UPnPTMRTP/H.264 BonjourMaintenance SupportSupport Overview System OverviewReset to factory default settings ScriptingFile Upload Plain ConfigTroubleshooting TroubleshootingEmergency recovery procedure Checking the firmwareProblems setting the IP address Symptoms, possible causes and remedial actionsProduct cannot be accessed from a browser Problems with the H.264 format Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Video and image problems, general Video Camera SettingsProblems uploading files No images displayed on webMotion Detection triggers unexpectedly Changes in luminanceTechnical Specifications Technical SpecificationsMaintenance Installation aids Memory PowerConnectors DimensionsPerformance considerations M1.7