Troubleshooting

The product is accessible locally but not externally

Router configuration

To configure your router to allow incoming data traffic to the Axis product, enable the NAT-traversal

 

feature which will attempt to automatically configure the router to allow access to the Axis

 

product, see NAT traversal (port mapping) for IPv4, on page 36. The router must support UPnPTM.

Firewall protection

Check the Internet firewall with your network administrator.

Default routers required

Check if you need to configure the router settings.

Problems with the H.264 format

No H.264 displayed in the client

No multicast H.264 displayed in the client

Multicast H.264 only accessible by local clients

Poor rendering of H.264 images

Color saturation is different in H.264 and Motion JPEG

Lower frame rate than expected

Why do I not get maximum frames per second?

Image degeneration

Check that the relevant H.264 connection methods and correct interface are enabled in the AMC Control Panel (streaming tab). See AXIS Media Control (AMC), on page 10.

In the AMC Control Panel, select the H.264 tab and click Set to default H.264 decoder.

Check that RTSP is enabled under System Options > Network > TCP/IP > Advanced.

Check with your network administrator that the multicast addresses used by the Axis product are valid for your network.

Check with your network administrator to see if there is a firewall preventing viewing.

Check if your router supports multicasting, or if the router settings between the client and the product need to be configured. The TTL (Time To Live) value may need to be increased.

Color depth set incorrectly on clients. Set to 16–bit or 32–bit color.

If text overlays are blurred, or if there are other rendering problems, you may need to enable Advanced Video Rendering fromv the Video tab in the AMC Control Panel.

Ensure that your graphics card is using the latest driver. The latest drivers can usually be downloaded from the manufacturer’s website.

Modify the settings for your graphics adapter. Refer to the adapter’s documentation for more information.

Reduce the number of applications running on the client computer.

Limit the number of simultaneous viewers.

Check with the network administrator that there is enough bandwidth available.

Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only key frames.

Lower the image resolution.

See Performance considerations, on page 48.

The maximum frames per second is dependent on the utility frequency (60/50 Hz) of the Axis product. See Technical Specifications, on page 46.

Decrease the GOV length. Go to Video > Video Stream and select the H.264 tab to modify the GOV length.

Status and Network indicator LEDs are flashing red rapidly

Hardware failure

Contact your Axis reseller.

43

Image 43
Contents Axis M3014 Network Camera Equipment Modifications About this documentLiability Intellectual Property RightsAxis M3014 Network Camera Table of ContentsHardware overview Hardware overviewColor Indication ConnectorsLED indicators MaintenanceAccessing the product Accessing the productAccess from a browser Click Create self-signed certificate Access from the InternetSet the root password Network TCP/IP AdvancedLive View Set Power Line FrequencyControls on the Live View PTZ Controls Axis Media Control viewer toolbarAxis Media Control AMC How to stream H.264Media streams Media streamsAlternative methods of accessing the video stream Axis M3014 Network Camera Setting up the product Setting up the productBasic Setup Pixel Counter VideoVideo Video StreamImage Stream Profiles264 Image Appearance Camera SettingsExposure Settings View AreaPrivacy Mask OverlayOverlay image Live View Config Default viewer for browsersLive View Config User Defined Links Viewer SettingsBrowser Viewer Description Guard Tour Preset PositionsPTZ Pan Tilt Zoom PTZ Pan Tilt ZoomControls AdvancedMotion Detection DetectorsDetectors Camera TamperingMotion detection parameters Set up motion detectionLow level 0% Default valuesRecommended values Applications ApplicationsEvents EventsConvert Event Types to Action Rules Setting Up an Action RuleGo to Events Action Rules and click Add Schedules RecipientsRecurrences Axis M3014 Network Camera Continuous recording RecordingsRecordings Recording ListAxis M3014 Network Camera Users System OptionsSystem Options SecurityIeee Date & TimeNetwork Basic TCP/IP SettingsAdvanced TCP/IP Settings NAT traversal port mapping for IPv4 HttpSmtp email QoS Quality of ServiceBonjour StorageUPnPTM RTP/H.264System Overview MaintenanceSupport Support OverviewPlain Config Reset to factory default settingsScripting File UploadChecking the firmware TroubleshootingTroubleshooting Emergency recovery procedureProblems setting the IP address Symptoms, possible causes and remedial actionsProduct cannot be accessed from a browser Problems with the H.264 format Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly No images displayed on web Video and image problems, generalVideo Camera Settings Problems uploading filesChanges in luminance Motion Detection triggers unexpectedlyTechnical Specifications Technical SpecificationsDimensions Maintenance Installation aidsMemory Power ConnectorsPerformance considerations M1.7