Axis Communications M3024LVE user manual Network, Basic TCP/IP Settings

Page 39

AXIS M3024–LVE Network Camera

System Options

If using a host name for the NTP server, a DNS server must be configured. See DNS Configuration, on page 41.

Set manually – Allows you to manually set date and time.

If using an NTP server, select your Time zone from the drop-down list. If required, check Automatically adjust for daylight saving time changes.

The Date & Time Format Used in Images is the date and time format displayed as a text overlay in the video stream. Use the

predefined formats or see File Naming & Date/Time Formats in the online help for information on how to create custom date and time formats. To include date and time in the overlay text, go to Video and select Include date and Include time.

Network

Basic TCP/IP Settings

The Axis product supports IP version 4 and IP version 6. Both versions can be enabled simultaneously, and at least one version must always be enabled.

IPv4 Address Configuration

By default, the Axis product is set to use IPv4 (IP version 4) and to obtain the IP address automatically via DHCP. The IPv4 settings are configured under System Options > Network > TCP/IP > Basic.

DHCP (Dynamic Host Configuration Protocol) allows network administrators to centrally manage and automate the assignment of IP addresses. DHCP should only be enabled if using dynamic IP address notification, or if the DHCP can update a DNS server. It is then possible to access the Axis product by name (host name).

If DHCP is enabled and the product cannot be accessed, run AXIS IP Utility to search the network for connected Axis products, or reset the product to the factory default settings (see page 47) and then perform the installation again.

To use a static IP address, check Use the following IP address and specify the IP address, subnet mask and default router.

IPv6 Address Configuration

If IPv6 (IP version 6) is enabled, the Axis product will receive an IP address according to the configuration in the network router.

To enable IPv6, go to System Options > Network > TCP/IP > Basic. Other settings for IPv6 should be configured in the network router.

ARP/Ping

The product’s IP address can be assigned using ARP and Ping. For instructions, see Assign IP Address Using ARP/Ping, on page 39.

The ARP/Ping service is enabled by default but is automatically disabled two minutes after the product is started, or as soon as an IP address is assigned. To re-assign IP address using ARP/Ping, the product must be restarted to enable ARP/Ping for an additional two minutes.

To disable the service, go to System Options > Network > TCP/IP > Basic and clear the option Enable ARP/Ping setting of IP address.

Pinging the product is still possible when the service is disabled.

Assign IP Address Using ARP/Ping

The product's IP address can be assigned using ARP/Ping. The command must be issued within 2 minutes of connecting power.

1.Acquire a free static IP address on the same network segment as the computer.

2.Locate the serial number (S/N) on the product label.

3.Open a command prompt and enter the following commands:

39

Image 39
Contents Axis M3024-LVE Network Camera Intellectual Property Rights About this DocumentLegal Considerations LiabilityLearn More SupportAxis M3024-LVE Network Camera Table of ContentsHardware Overview Connectors and ButtonsNetwork Connector Hardware OverviewControl Button LED IndicatorsConnector SD Card SlotAccessing the Product Accessing the ProductAccess from a Browser Accessing the Product Access from the Internet Set the Root PasswordClick Create self-signed certificate Set Power Line Frequency Live ViewControls on the Live View Go to Setup Events Axis Media Control viewer toolbarManual Trigger PTZ Controls Axis Media Control AMC How to Stream H.264Media Streams Media StreamsAlternative Methods of Accessing the Video Stream Axis M3024-LVE Network Camera Setting Up the Product Setting Up the ProductBasic Setup Setting Up the Product Video Video StreamPixel Counter Stream Profiles Image264 White Balance Camera SettingsExposure Settings Image AppearanceView Area OverlayBuilt-in IR Illuminations LEDs Privacy Mask Overlay ImageGo to Video Overlay Image Live View Config Live View ConfigDefault Viewer for Browsers Output Buttons Viewer SettingsGo to Setup Live View Config User Defined LinksAxis M3024-LVE Network Camera Advanced Preset PositionsPTZ Pan Tilt Zoom PTZ Pan Tilt ZoomAxis M3024-LVE Network Camera Motion Detection DetectorsDetectors Camera TamperingParameter Object Size History Sensitivity Description Set Up Motion Detection WindowsMotion Detection Parameters Go to Detectors Motion DetectionRecommended values Default valuesMedium level 50% Low level 0%Application Licenses Install ApplicationApplications ApplicationsAxis M3024-LVE Network Camera Events EventsGo to Events Action Rules and click Add Setting Up an Action RuleTime PTZ ControlRecipients SchedulesRecurrences Go to Events Recurrences and click Add Continuous Recording RecordingsRecordings Recording List Languages LanguagesUsers System OptionsSystem Options SecurityDate & Time IeeeCertificates Network Basic TCP/IP SettingsAxis Video Hosting System Avhs Axis Internet Dynamic DNS ServiceLinux/Unix syntax Linux/Unix exampleHost Name Configuration Advanced TCP/IP SettingsDNS Configuration NTP ConfigurationFTP NAT traversal port mapping for IPv4UPnPTM QoS Quality of ServiceUPnPTM can be disabled under System Options Network UPnPTM Smtp emailSD Card StorageRTP/H.264 BonjourPorts MaintenancePorts & Devices Network ShareLogs & Reports SupportSupport Overview System OverviewScripting Reset to Factory Default SettingsPlain Config System Options AdvancedChecking the Firmware TroubleshootingTroubleshooting Emergency Recovery ProcedureSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externally Problems with streaming H.264Basic Problem Retrieving Additional Video Streams Technical Specifications Technical SpecificationsDimensions Function/group Specifications System ApplicationPower ConnectorsFunction Pin Specifications ConnectorsFunction/group Specifications Weight 820 g 12.8 lb Included ConnectorPerformance Considerations M2.4